Corrosion Characteristics of Anchor Cables in Electrolytic Corrosion Test and the Applicability of the Test Method in Study of Anchor Cable Corrosion
The selection of corrosion test method in the corrosion study of the prestressed anchors is an important issue. In this paper, the corrosion test of anchors was conducted with electrolytic corrosion test method. The corrosion characteristics of the anchor cables were examined. The effects of sodium...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2021-01-01
|
Series: | Advances in Civil Engineering |
Online Access: | http://dx.doi.org/10.1155/2021/6695288 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832565981688365056 |
---|---|
author | Tao Yin Xingsong Sun Yujie Wang Yufei Zhao Shuangjing Wang Lipeng Liu Hongjie Chen |
author_facet | Tao Yin Xingsong Sun Yujie Wang Yufei Zhao Shuangjing Wang Lipeng Liu Hongjie Chen |
author_sort | Tao Yin |
collection | DOAJ |
description | The selection of corrosion test method in the corrosion study of the prestressed anchors is an important issue. In this paper, the corrosion test of anchors was conducted with electrolytic corrosion test method. The corrosion characteristics of the anchor cables were examined. The effects of sodium chloride solution concentration, current, test time, and prestress level on corrosion were studied. The applicability of electrolytic corrosion method in anchor cable corrosion study is discussed subsequently. The results show that the corrosion of the anchor appears to be uniform corrosion. With the corrosion of the anchor, the central wire of the cable was basically not corroded, and the cross-sectional shape of the outer wire changes from a round to fan shape. The sodium chloride concentration and prestress level have no obvious effects on the corrosion of the anchor. The variation of test time does not affect the difference between the measured and theoretical calculated results, while a proper current in the electrolysis test may help reduce the difference. The measured corrosion rate fluctuates from −4% to 10% and tends to be higher compared with calculated results based on Faraday’s law. The study indicates that the electrolytic corrosion test is applicable in the anchor corrosion study. |
format | Article |
id | doaj-art-301d4e2718b84090b77ec1555e43281b |
institution | Kabale University |
issn | 1687-8086 1687-8094 |
language | English |
publishDate | 2021-01-01 |
publisher | Wiley |
record_format | Article |
series | Advances in Civil Engineering |
spelling | doaj-art-301d4e2718b84090b77ec1555e43281b2025-02-03T01:05:25ZengWileyAdvances in Civil Engineering1687-80861687-80942021-01-01202110.1155/2021/66952886695288Corrosion Characteristics of Anchor Cables in Electrolytic Corrosion Test and the Applicability of the Test Method in Study of Anchor Cable CorrosionTao Yin0Xingsong Sun1Yujie Wang2Yufei Zhao3Shuangjing Wang4Lipeng Liu5Hongjie Chen6State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research, Beijing 100038, ChinaState Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research, Beijing 100038, ChinaState Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research, Beijing 100038, ChinaState Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research, Beijing 100038, ChinaState Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research, Beijing 100038, ChinaState Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research, Beijing 100038, ChinaHuaneng Lancang River Hydropower Inc., Kunming, Yunnan 650206, ChinaThe selection of corrosion test method in the corrosion study of the prestressed anchors is an important issue. In this paper, the corrosion test of anchors was conducted with electrolytic corrosion test method. The corrosion characteristics of the anchor cables were examined. The effects of sodium chloride solution concentration, current, test time, and prestress level on corrosion were studied. The applicability of electrolytic corrosion method in anchor cable corrosion study is discussed subsequently. The results show that the corrosion of the anchor appears to be uniform corrosion. With the corrosion of the anchor, the central wire of the cable was basically not corroded, and the cross-sectional shape of the outer wire changes from a round to fan shape. The sodium chloride concentration and prestress level have no obvious effects on the corrosion of the anchor. The variation of test time does not affect the difference between the measured and theoretical calculated results, while a proper current in the electrolysis test may help reduce the difference. The measured corrosion rate fluctuates from −4% to 10% and tends to be higher compared with calculated results based on Faraday’s law. The study indicates that the electrolytic corrosion test is applicable in the anchor corrosion study.http://dx.doi.org/10.1155/2021/6695288 |
spellingShingle | Tao Yin Xingsong Sun Yujie Wang Yufei Zhao Shuangjing Wang Lipeng Liu Hongjie Chen Corrosion Characteristics of Anchor Cables in Electrolytic Corrosion Test and the Applicability of the Test Method in Study of Anchor Cable Corrosion Advances in Civil Engineering |
title | Corrosion Characteristics of Anchor Cables in Electrolytic Corrosion Test and the Applicability of the Test Method in Study of Anchor Cable Corrosion |
title_full | Corrosion Characteristics of Anchor Cables in Electrolytic Corrosion Test and the Applicability of the Test Method in Study of Anchor Cable Corrosion |
title_fullStr | Corrosion Characteristics of Anchor Cables in Electrolytic Corrosion Test and the Applicability of the Test Method in Study of Anchor Cable Corrosion |
title_full_unstemmed | Corrosion Characteristics of Anchor Cables in Electrolytic Corrosion Test and the Applicability of the Test Method in Study of Anchor Cable Corrosion |
title_short | Corrosion Characteristics of Anchor Cables in Electrolytic Corrosion Test and the Applicability of the Test Method in Study of Anchor Cable Corrosion |
title_sort | corrosion characteristics of anchor cables in electrolytic corrosion test and the applicability of the test method in study of anchor cable corrosion |
url | http://dx.doi.org/10.1155/2021/6695288 |
work_keys_str_mv | AT taoyin corrosioncharacteristicsofanchorcablesinelectrolyticcorrosiontestandtheapplicabilityofthetestmethodinstudyofanchorcablecorrosion AT xingsongsun corrosioncharacteristicsofanchorcablesinelectrolyticcorrosiontestandtheapplicabilityofthetestmethodinstudyofanchorcablecorrosion AT yujiewang corrosioncharacteristicsofanchorcablesinelectrolyticcorrosiontestandtheapplicabilityofthetestmethodinstudyofanchorcablecorrosion AT yufeizhao corrosioncharacteristicsofanchorcablesinelectrolyticcorrosiontestandtheapplicabilityofthetestmethodinstudyofanchorcablecorrosion AT shuangjingwang corrosioncharacteristicsofanchorcablesinelectrolyticcorrosiontestandtheapplicabilityofthetestmethodinstudyofanchorcablecorrosion AT lipengliu corrosioncharacteristicsofanchorcablesinelectrolyticcorrosiontestandtheapplicabilityofthetestmethodinstudyofanchorcablecorrosion AT hongjiechen corrosioncharacteristicsofanchorcablesinelectrolyticcorrosiontestandtheapplicabilityofthetestmethodinstudyofanchorcablecorrosion |