Research on the Method of Depth Peaking at Full Load of Supercritical Circulating Fluidized Bed Unit

With the expansion of installed capacity of new energy power generation, the thermal power market has been severely squeezed. To meet the needs of grid flexibility, thermal power plants are required to undertake the task of deep peak shaving. Circulating fluidized bed units can be used without shutd...

Full description

Saved in:
Bibliographic Details
Main Authors: Bin NIU, Lifeng LI, Qian SUN, Peihua ZHANG
Format: Article
Language:English
Published: Editorial Department of Power Generation Technology 2021-04-01
Series:发电技术
Subjects:
Online Access:https://www.pgtjournal.com/EN/10.12096/j.2096-4528.pgt.20024
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850062623488344064
author Bin NIU
Lifeng LI
Qian SUN
Peihua ZHANG
author_facet Bin NIU
Lifeng LI
Qian SUN
Peihua ZHANG
author_sort Bin NIU
collection DOAJ
description With the expansion of installed capacity of new energy power generation, the thermal power market has been severely squeezed. To meet the needs of grid flexibility, thermal power plants are required to undertake the task of deep peak shaving. Circulating fluidized bed units can be used without shutdown. It takes a supercritical 350MW circulating fluidized bed unit in a power plant in Shanxi Province as the research object. Two kinds of deep peak shaving methods of supercritical circulating fluidized bed unit's typical steam-water systems were analyzed. Some problems that might be encountered during operation were analyzed. Corresponding prevention and control measures were provided. Finally, the analysis shows that the supercritical circulating fluidized bed unit can use two typical steam-water systems to achieve full load deep peak shaving. The investment of adding boiler water circulating pump system is large, and the operation is complex. The investment of adding water storage tank to deaerator pipeline is small, and the operation is simple. However, when the boiler water circulating pump system is added to participate in full load deep peak shaving, the stability of each system is better.
format Article
id doaj-art-300dc8a2cf2341a1afa9acb3dcbecc17
institution DOAJ
issn 2096-4528
language English
publishDate 2021-04-01
publisher Editorial Department of Power Generation Technology
record_format Article
series 发电技术
spelling doaj-art-300dc8a2cf2341a1afa9acb3dcbecc172025-08-20T02:49:52ZengEditorial Department of Power Generation Technology发电技术2096-45282021-04-0142227327910.12096/j.2096-4528.pgt.20024fdjs-42-2-273Research on the Method of Depth Peaking at Full Load of Supercritical Circulating Fluidized Bed UnitBin NIU0Lifeng LI1Qian SUN2Peihua ZHANG3School of Mathematical Sciences, Shanxi University, Taiyuan 030006, Shanxi Province, ChinaShanxi Hepo Power Generation Co., Ltd., Yangquan 045000, Shanxi Province, ChinaSchool of Mathematical Sciences, Shanxi University, Taiyuan 030006, Shanxi Province, ChinaInstitute of Resource and Environment Engineering, Shanxi University, Taiyuan 030006, Shanxi Province, ChinaWith the expansion of installed capacity of new energy power generation, the thermal power market has been severely squeezed. To meet the needs of grid flexibility, thermal power plants are required to undertake the task of deep peak shaving. Circulating fluidized bed units can be used without shutdown. It takes a supercritical 350MW circulating fluidized bed unit in a power plant in Shanxi Province as the research object. Two kinds of deep peak shaving methods of supercritical circulating fluidized bed unit's typical steam-water systems were analyzed. Some problems that might be encountered during operation were analyzed. Corresponding prevention and control measures were provided. Finally, the analysis shows that the supercritical circulating fluidized bed unit can use two typical steam-water systems to achieve full load deep peak shaving. The investment of adding boiler water circulating pump system is large, and the operation is complex. The investment of adding water storage tank to deaerator pipeline is small, and the operation is simple. However, when the boiler water circulating pump system is added to participate in full load deep peak shaving, the stability of each system is better.https://www.pgtjournal.com/EN/10.12096/j.2096-4528.pgt.20024supercritical circulating fluidized bed unitdepth peakingseparatorwater storage tankdeaerator
spellingShingle Bin NIU
Lifeng LI
Qian SUN
Peihua ZHANG
Research on the Method of Depth Peaking at Full Load of Supercritical Circulating Fluidized Bed Unit
发电技术
supercritical circulating fluidized bed unit
depth peaking
separator
water storage tank
deaerator
title Research on the Method of Depth Peaking at Full Load of Supercritical Circulating Fluidized Bed Unit
title_full Research on the Method of Depth Peaking at Full Load of Supercritical Circulating Fluidized Bed Unit
title_fullStr Research on the Method of Depth Peaking at Full Load of Supercritical Circulating Fluidized Bed Unit
title_full_unstemmed Research on the Method of Depth Peaking at Full Load of Supercritical Circulating Fluidized Bed Unit
title_short Research on the Method of Depth Peaking at Full Load of Supercritical Circulating Fluidized Bed Unit
title_sort research on the method of depth peaking at full load of supercritical circulating fluidized bed unit
topic supercritical circulating fluidized bed unit
depth peaking
separator
water storage tank
deaerator
url https://www.pgtjournal.com/EN/10.12096/j.2096-4528.pgt.20024
work_keys_str_mv AT binniu researchonthemethodofdepthpeakingatfullloadofsupercriticalcirculatingfluidizedbedunit
AT lifengli researchonthemethodofdepthpeakingatfullloadofsupercriticalcirculatingfluidizedbedunit
AT qiansun researchonthemethodofdepthpeakingatfullloadofsupercriticalcirculatingfluidizedbedunit
AT peihuazhang researchonthemethodofdepthpeakingatfullloadofsupercriticalcirculatingfluidizedbedunit