The use of a two-frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift-off

The paper addresses the problem of eddy current testing of the wall thickness of light-alloy drill pipes under significant variations in both the test and the influence parameter of the test object – the lift-off between the eddy current probe and the test object surface. The performance of the two...

Full description

Saved in:
Bibliographic Details
Main Authors: A.E. Гольдштейн, Х.Х. Абакумов
Format: Article
Language:English
Published: Academician Ye.A. Buketov Karaganda University 2022-06-01
Series:Қарағанды университетінің хабаршысы. Физика сериясы
Subjects:
Online Access:https://phs.buketov.edu.kz/index.php/physics-vestnik/article/view/443
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850149029680250880
author A.E. Гольдштейн
Х.Х. Абакумов
author_facet A.E. Гольдштейн
Х.Х. Абакумов
author_sort A.E. Гольдштейн
collection DOAJ
description The paper addresses the problem of eddy current testing of the wall thickness of light-alloy drill pipes under significant variations in both the test and the influence parameter of the test object – the lift-off between the eddy current probe and the test object surface. The performance of the two-frequency eddy current method is shown through the use of the signal of the surface eddy current probe of the added high-frequency voltage amplitude as an informative parameter to measure the lift-off and the phase of the added low-frequency voltage. Experimentally obtained dependences of the informative parameters on test and influence parameters are presented. The phase and amplitude-phase multi-parameter methods used to suppress the effect of stray parameters in eddy current testing are analyzed; the effectiveness of their application under significant variations in test and other influence parameters of the test object is shown to be limited. The effectiveness of nonlinear functions for the inverse transformation of the informative parameter into the test parameter to suppress the lift-off effect on test results is estimated. Criteria of choice for informative parameters of the eddy current probe signal are considered. The measurement error caused by the approximation error of the nonlinear functions of the inverse transformation of the informative parameters into the test parameter within the variation ranges of the test and influence parameters is estimated.
format Article
id doaj-art-2f99dcb8a4614b7c8bb6cbc4077a3cab
institution OA Journals
issn 2518-7198
2663-5089
language English
publishDate 2022-06-01
publisher Academician Ye.A. Buketov Karaganda University
record_format Article
series Қарағанды университетінің хабаршысы. Физика сериясы
spelling doaj-art-2f99dcb8a4614b7c8bb6cbc4077a3cab2025-08-20T02:27:05ZengAcademician Ye.A. Buketov Karaganda UniversityҚарағанды университетінің хабаршысы. Физика сериясы2518-71982663-50892022-06-01106210.31489/2022ph2/24-31The use of a two-frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift-off A.E. ГольдштейнХ.Х. Абакумов The paper addresses the problem of eddy current testing of the wall thickness of light-alloy drill pipes under significant variations in both the test and the influence parameter of the test object – the lift-off between the eddy current probe and the test object surface. The performance of the two-frequency eddy current method is shown through the use of the signal of the surface eddy current probe of the added high-frequency voltage amplitude as an informative parameter to measure the lift-off and the phase of the added low-frequency voltage. Experimentally obtained dependences of the informative parameters on test and influence parameters are presented. The phase and amplitude-phase multi-parameter methods used to suppress the effect of stray parameters in eddy current testing are analyzed; the effectiveness of their application under significant variations in test and other influence parameters of the test object is shown to be limited. The effectiveness of nonlinear functions for the inverse transformation of the informative parameter into the test parameter to suppress the lift-off effect on test results is estimated. Criteria of choice for informative parameters of the eddy current probe signal are considered. The measurement error caused by the approximation error of the nonlinear functions of the inverse transformation of the informative parameters into the test parameter within the variation ranges of the test and influence parameters is estimated. https://phs.buketov.edu.kz/index.php/physics-vestnik/article/view/443thickness measurementsurface eddy current probesignal hodographsstray parameterssuppression in eddy current testing
spellingShingle A.E. Гольдштейн
Х.Х. Абакумов
The use of a two-frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift-off
Қарағанды университетінің хабаршысы. Физика сериясы
thickness measurement
surface eddy current probe
signal hodographs
stray parameters
suppression in eddy current testing
title The use of a two-frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift-off
title_full The use of a two-frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift-off
title_fullStr The use of a two-frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift-off
title_full_unstemmed The use of a two-frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift-off
title_short The use of a two-frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift-off
title_sort use of a two frequency eddy current method for measuring the electrically conductive wall thickness under significant variations in the test parameter and the lift off
topic thickness measurement
surface eddy current probe
signal hodographs
stray parameters
suppression in eddy current testing
url https://phs.buketov.edu.kz/index.php/physics-vestnik/article/view/443
work_keys_str_mv AT aegolʹdštejn theuseofatwofrequencyeddycurrentmethodformeasuringtheelectricallyconductivewallthicknessundersignificantvariationsinthetestparameterandtheliftoff
AT hhabakumov theuseofatwofrequencyeddycurrentmethodformeasuringtheelectricallyconductivewallthicknessundersignificantvariationsinthetestparameterandtheliftoff
AT aegolʹdštejn useofatwofrequencyeddycurrentmethodformeasuringtheelectricallyconductivewallthicknessundersignificantvariationsinthetestparameterandtheliftoff
AT hhabakumov useofatwofrequencyeddycurrentmethodformeasuringtheelectricallyconductivewallthicknessundersignificantvariationsinthetestparameterandtheliftoff