Development and Validation of an Indicator System for Evaluating Clinical Nursing Process Quality Using Mobile Nursing Information Systems

Hongyue Ge,1,* Qiao Wang,1,* Sibo Liu,1 Yanbin Tian,2 Jie Ma3 1Department of Integrated Traditional and Western Cardiology, China-Japan Friendship Hospital, Beijing, 100029, People’s Republic of China; 2Department of Information Center, China-Japan Friendship Hospital, Beijing, 10002...

Full description

Saved in:
Bibliographic Details
Main Authors: Ge H, Wang Q, Liu S, Tian Y, Ma J
Format: Article
Language:English
Published: Dove Medical Press 2025-04-01
Series:Journal of Multidisciplinary Healthcare
Subjects:
Online Access:https://www.dovepress.com/development-and-validation-of-an-indicator-system-for-evaluating-clini-peer-reviewed-fulltext-article-JMDH
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849316128154714112
author Ge H
Wang Q
Liu S
Tian Y
Ma J
author_facet Ge H
Wang Q
Liu S
Tian Y
Ma J
author_sort Ge H
collection DOAJ
description Hongyue Ge,1,&ast; Qiao Wang,1,&ast; Sibo Liu,1 Yanbin Tian,2 Jie Ma3 1Department of Integrated Traditional and Western Cardiology, China-Japan Friendship Hospital, Beijing, 100029, People’s Republic of China; 2Department of Information Center, China-Japan Friendship Hospital, Beijing, 100029, People’s Republic of China; 3Department of Nursing, China-Japan Friendship Hospital, Beijing, 100029, People’s Republic of China&ast;These authors contributed equally to this workCorrespondence: Qiao Wang, Department of Integrated Traditional and Western Cardiology, China-Japan Friendship Hospital, No. 2 of Yinghua East Street, ChaoYang District, Beijing, 100029, People’s Republic of China, Tel +86 13522550614, Email qiaowang_wq@126.comObjective: This study aimed to develop and validate a standardized indicator system to assess clinical nursing process quality, leveraging a mobile nursing information system to enhance care efficiency and safety.Methods: A Delphi method was employed, with indicator weights assigned via a precedence ordering chart. Data from three distinct clinical departments were analyzed to test the system, focusing on 20 indicators spanning assessment, execution, guidance, and management domains.Results: Both rounds of expert consultation achieved 100% response rates, with high authority coefficients (0.89 and 0.90). Kendall’s concordance coefficients indicated moderate agreement among experts (W = 0.21, P < 0.05; W = 0.129, P < 0.05). The mean importance scores for each indicator ranged from 3.85 to 5.00, with coefficients of variation ranging from 0.00 to 0.24. The final system included 4 primary indicators (assessment [weight: 0.438], execution [0.313], guidance [0.125], management [0.125]) and 44 secondary indicators. Significant variations emerged across departments. One department demonstrated significantly lower execution rates for subcutaneous, intradermal, intramuscular, and intravenous injections, nebulization inhalation, oral medication, and intravenous infusion compared to the other two departments (P < 0.05). Similarly, another department exhibited a significantly lower rate of timely submission of blood, urine, stool, and sputum specimens compared to the other departments (P < 0.05).Conclusion: The indicator system developed for evaluating the quality of clinical nursing processes within a mobile nursing information system demonstrated scientific reliability and validity, with appropriately assigned indicator weights. This system shows promise as a potentially effective means of evaluating the quality of clinical nursing processes. Future research could build on the results of this study to further validate the timeliness and objectivity of this indicator system in assessing the quality of the nursing process.Keywords: clinical care classification system (CCC system), delphi method, quality of health care, mobile health, nursing processes
format Article
id doaj-art-2e8e7183974e4c3a8a2ebb2624b7fbf6
institution Kabale University
issn 1178-2390
language English
publishDate 2025-04-01
publisher Dove Medical Press
record_format Article
series Journal of Multidisciplinary Healthcare
spelling doaj-art-2e8e7183974e4c3a8a2ebb2624b7fbf62025-08-20T03:51:58ZengDove Medical PressJournal of Multidisciplinary Healthcare1178-23902025-04-01Volume 1822252236102274Development and Validation of an Indicator System for Evaluating Clinical Nursing Process Quality Using Mobile Nursing Information SystemsGe HWang QLiu STian YMa JHongyue Ge,1,&ast; Qiao Wang,1,&ast; Sibo Liu,1 Yanbin Tian,2 Jie Ma3 1Department of Integrated Traditional and Western Cardiology, China-Japan Friendship Hospital, Beijing, 100029, People’s Republic of China; 2Department of Information Center, China-Japan Friendship Hospital, Beijing, 100029, People’s Republic of China; 3Department of Nursing, China-Japan Friendship Hospital, Beijing, 100029, People’s Republic of China&ast;These authors contributed equally to this workCorrespondence: Qiao Wang, Department of Integrated Traditional and Western Cardiology, China-Japan Friendship Hospital, No. 2 of Yinghua East Street, ChaoYang District, Beijing, 100029, People’s Republic of China, Tel +86 13522550614, Email qiaowang_wq@126.comObjective: This study aimed to develop and validate a standardized indicator system to assess clinical nursing process quality, leveraging a mobile nursing information system to enhance care efficiency and safety.Methods: A Delphi method was employed, with indicator weights assigned via a precedence ordering chart. Data from three distinct clinical departments were analyzed to test the system, focusing on 20 indicators spanning assessment, execution, guidance, and management domains.Results: Both rounds of expert consultation achieved 100% response rates, with high authority coefficients (0.89 and 0.90). Kendall’s concordance coefficients indicated moderate agreement among experts (W = 0.21, P < 0.05; W = 0.129, P < 0.05). The mean importance scores for each indicator ranged from 3.85 to 5.00, with coefficients of variation ranging from 0.00 to 0.24. The final system included 4 primary indicators (assessment [weight: 0.438], execution [0.313], guidance [0.125], management [0.125]) and 44 secondary indicators. Significant variations emerged across departments. One department demonstrated significantly lower execution rates for subcutaneous, intradermal, intramuscular, and intravenous injections, nebulization inhalation, oral medication, and intravenous infusion compared to the other two departments (P < 0.05). Similarly, another department exhibited a significantly lower rate of timely submission of blood, urine, stool, and sputum specimens compared to the other departments (P < 0.05).Conclusion: The indicator system developed for evaluating the quality of clinical nursing processes within a mobile nursing information system demonstrated scientific reliability and validity, with appropriately assigned indicator weights. This system shows promise as a potentially effective means of evaluating the quality of clinical nursing processes. Future research could build on the results of this study to further validate the timeliness and objectivity of this indicator system in assessing the quality of the nursing process.Keywords: clinical care classification system (CCC system), delphi method, quality of health care, mobile health, nursing processeshttps://www.dovepress.com/development-and-validation-of-an-indicator-system-for-evaluating-clini-peer-reviewed-fulltext-article-JMDHclinical care classification systemccc systemdelphi methodquality of health caremobile healthnursing processes
spellingShingle Ge H
Wang Q
Liu S
Tian Y
Ma J
Development and Validation of an Indicator System for Evaluating Clinical Nursing Process Quality Using Mobile Nursing Information Systems
Journal of Multidisciplinary Healthcare
clinical care classification system
ccc system
delphi method
quality of health care
mobile health
nursing processes
title Development and Validation of an Indicator System for Evaluating Clinical Nursing Process Quality Using Mobile Nursing Information Systems
title_full Development and Validation of an Indicator System for Evaluating Clinical Nursing Process Quality Using Mobile Nursing Information Systems
title_fullStr Development and Validation of an Indicator System for Evaluating Clinical Nursing Process Quality Using Mobile Nursing Information Systems
title_full_unstemmed Development and Validation of an Indicator System for Evaluating Clinical Nursing Process Quality Using Mobile Nursing Information Systems
title_short Development and Validation of an Indicator System for Evaluating Clinical Nursing Process Quality Using Mobile Nursing Information Systems
title_sort development and validation of an indicator system for evaluating clinical nursing process quality using mobile nursing information systems
topic clinical care classification system
ccc system
delphi method
quality of health care
mobile health
nursing processes
url https://www.dovepress.com/development-and-validation-of-an-indicator-system-for-evaluating-clini-peer-reviewed-fulltext-article-JMDH
work_keys_str_mv AT geh developmentandvalidationofanindicatorsystemforevaluatingclinicalnursingprocessqualityusingmobilenursinginformationsystems
AT wangq developmentandvalidationofanindicatorsystemforevaluatingclinicalnursingprocessqualityusingmobilenursinginformationsystems
AT lius developmentandvalidationofanindicatorsystemforevaluatingclinicalnursingprocessqualityusingmobilenursinginformationsystems
AT tiany developmentandvalidationofanindicatorsystemforevaluatingclinicalnursingprocessqualityusingmobilenursinginformationsystems
AT maj developmentandvalidationofanindicatorsystemforevaluatingclinicalnursingprocessqualityusingmobilenursinginformationsystems