Extraction and Analysis of Strontium in Water Sample Using a Sr2+ Selective Polymer as the Absorbent Phase

A kind of Sr2+ selective resin was applied as an absorption phase to extract Sr2+ ion from an aqueous solution, and the amount of Sr2+ was determined using inductively coupled plasma optical emission spectrometer. Factors, including absorption time, temperature, stirring rate, salt-out effect, desor...

Full description

Saved in:
Bibliographic Details
Main Author: Rongjian Ying
Format: Article
Language:English
Published: Wiley 2015-01-01
Series:International Journal of Analytical Chemistry
Online Access:http://dx.doi.org/10.1155/2015/425084
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849693389257179136
author Rongjian Ying
author_facet Rongjian Ying
author_sort Rongjian Ying
collection DOAJ
description A kind of Sr2+ selective resin was applied as an absorption phase to extract Sr2+ ion from an aqueous solution, and the amount of Sr2+ was determined using inductively coupled plasma optical emission spectrometer. Factors, including absorption time, temperature, stirring rate, salt-out effect, desorption, and the pH of the aqueous solution, were investigated to optimize the absorption efficiency of Sr2+. Foreign ions were examined to observe their effects on the absorption behavior of Sr2+. The optimum condition was absorption time at 20 min, pH of aqueous solution 7, temperature of 35°C, and 600 rpm stirring rate. A 10 mL solution of 0.1 mol/L HCl is used as the desorption agent. The linear range of Sr2+ concentrations from 50 to 1200 μg/L was investigated with the slope of 183 μg/L. The limit of detection was 21 μg/L with 4.23% relative standard deviation. The correlation coefficient was found to be 0.9947. Under the optimized conditions, the concentrations of Sr2+ in four water samples were detected by the developed method. We propose that this method effectively extracts strontium ion from environmental water samples.
format Article
id doaj-art-2dc3bcd688c74498b3e506b24d7f2ebf
institution DOAJ
issn 1687-8760
1687-8779
language English
publishDate 2015-01-01
publisher Wiley
record_format Article
series International Journal of Analytical Chemistry
spelling doaj-art-2dc3bcd688c74498b3e506b24d7f2ebf2025-08-20T03:20:26ZengWileyInternational Journal of Analytical Chemistry1687-87601687-87792015-01-01201510.1155/2015/425084425084Extraction and Analysis of Strontium in Water Sample Using a Sr2+ Selective Polymer as the Absorbent PhaseRongjian Ying0College of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, ChinaA kind of Sr2+ selective resin was applied as an absorption phase to extract Sr2+ ion from an aqueous solution, and the amount of Sr2+ was determined using inductively coupled plasma optical emission spectrometer. Factors, including absorption time, temperature, stirring rate, salt-out effect, desorption, and the pH of the aqueous solution, were investigated to optimize the absorption efficiency of Sr2+. Foreign ions were examined to observe their effects on the absorption behavior of Sr2+. The optimum condition was absorption time at 20 min, pH of aqueous solution 7, temperature of 35°C, and 600 rpm stirring rate. A 10 mL solution of 0.1 mol/L HCl is used as the desorption agent. The linear range of Sr2+ concentrations from 50 to 1200 μg/L was investigated with the slope of 183 μg/L. The limit of detection was 21 μg/L with 4.23% relative standard deviation. The correlation coefficient was found to be 0.9947. Under the optimized conditions, the concentrations of Sr2+ in four water samples were detected by the developed method. We propose that this method effectively extracts strontium ion from environmental water samples.http://dx.doi.org/10.1155/2015/425084
spellingShingle Rongjian Ying
Extraction and Analysis of Strontium in Water Sample Using a Sr2+ Selective Polymer as the Absorbent Phase
International Journal of Analytical Chemistry
title Extraction and Analysis of Strontium in Water Sample Using a Sr2+ Selective Polymer as the Absorbent Phase
title_full Extraction and Analysis of Strontium in Water Sample Using a Sr2+ Selective Polymer as the Absorbent Phase
title_fullStr Extraction and Analysis of Strontium in Water Sample Using a Sr2+ Selective Polymer as the Absorbent Phase
title_full_unstemmed Extraction and Analysis of Strontium in Water Sample Using a Sr2+ Selective Polymer as the Absorbent Phase
title_short Extraction and Analysis of Strontium in Water Sample Using a Sr2+ Selective Polymer as the Absorbent Phase
title_sort extraction and analysis of strontium in water sample using a sr2 selective polymer as the absorbent phase
url http://dx.doi.org/10.1155/2015/425084
work_keys_str_mv AT rongjianying extractionandanalysisofstrontiuminwatersampleusingasr2selectivepolymerastheabsorbentphase