Влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения

The article considers the influence of opportunities forcing synchronous generator (SG) and a synchronous motor (SM) to provide the required level of the residual voltage at the consumer at short circuits in networks of high voltage. It determines the ability of the equipment to remain in the work d...

Full description

Saved in:
Bibliographic Details
Format: Article
Language:English
Published: Kazan State Power Engineering University 2017-12-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/287
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850066983425409024
collection DOAJ
description The article considers the influence of opportunities forcing synchronous generator (SG) and a synchronous motor (SM) to provide the required level of the residual voltage at the consumer at short circuits in networks of high voltage. It determines the ability of the equipment to remain in the work during such perturbation by mathematical modeling.
format Article
id doaj-art-2da6cd423cb74390a371911da606f7eb
institution DOAJ
issn 1998-9903
language English
publishDate 2017-12-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj-art-2da6cd423cb74390a371911da606f7eb2025-08-20T02:48:33ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032017-12-0107-8647110.30724/1998-9903-2016-0-7-8-64-71287Влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения01Казанский государственный энергетический университетКазанский государственный энергетический университетThe article considers the influence of opportunities forcing synchronous generator (SG) and a synchronous motor (SM) to provide the required level of the residual voltage at the consumer at short circuits in networks of high voltage. It determines the ability of the equipment to remain in the work during such perturbation by mathematical modeling.https://www.energyret.ru/jour/article/view/287mathematical modelingelectrical networksynchronous motorsynchronous generatorresidual voltagepower qualityvoltage dipshort circuit
spellingShingle Влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения
Известия высших учебных заведений: Проблемы энергетики
mathematical modeling
electrical network
synchronous motor
synchronous generator
residual voltage
power quality
voltage dip
short circuit
title Влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения
title_full Влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения
title_fullStr Влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения
title_full_unstemmed Влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения
title_short Влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения
title_sort влияние форсировки возбуждения синхронных машин на уровень остаточного напряжения при кратковременных нарушениях электроснабжения
topic mathematical modeling
electrical network
synchronous motor
synchronous generator
residual voltage
power quality
voltage dip
short circuit
url https://www.energyret.ru/jour/article/view/287