LVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient Voltage

The renewable power gathering system often presents the characteristics of a weak AC grid. And the voltage fluctuates greatly during the failure process. The problem of renewable units being turned-off due to low voltage and transient overvoltage is prominent. This paper establishes the voltage-curr...

Full description

Saved in:
Bibliographic Details
Main Authors: Hui LIU, Kuo WANG
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2022-02-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202111041
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850069236920090624
author Hui LIU
Kuo WANG
author_facet Hui LIU
Kuo WANG
author_sort Hui LIU
collection DOAJ
description The renewable power gathering system often presents the characteristics of a weak AC grid. And the voltage fluctuates greatly during the failure process. The problem of renewable units being turned-off due to low voltage and transient overvoltage is prominent. This paper establishes the voltage-current relationship of the renewable power gathering system. Considering the safety constraints of low voltage and transient overvoltage, we gives the LVRT reactive current index requirements for the renewable units through theoretical derivation. Then, the renewable power gathering system is classified according to the short circuit ratio (SCR), and for systems with different SCRs, differentiated LVRT reactive current index requirements are given.
format Article
id doaj-art-2d475d7644be42e7a8c6653ebaa25e02
institution DOAJ
issn 1004-9649
language zho
publishDate 2022-02-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-2d475d7644be42e7a8c6653ebaa25e022025-08-20T02:47:49ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492022-02-0155215215810.11930/j.issn.1004-9649.202111041zgdl-55-3-liuhuiLVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient VoltageHui LIU0Kuo WANG1State Grid Jibei Electric Power Research Institute, Beijing 100045, ChinaPeking University, Beijing 100191, ChinaThe renewable power gathering system often presents the characteristics of a weak AC grid. And the voltage fluctuates greatly during the failure process. The problem of renewable units being turned-off due to low voltage and transient overvoltage is prominent. This paper establishes the voltage-current relationship of the renewable power gathering system. Considering the safety constraints of low voltage and transient overvoltage, we gives the LVRT reactive current index requirements for the renewable units through theoretical derivation. Then, the renewable power gathering system is classified according to the short circuit ratio (SCR), and for systems with different SCRs, differentiated LVRT reactive current index requirements are given.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202111041renewable power gathering systemlow voltage ride throughtransient overvoltageshort-circuit ratio
spellingShingle Hui LIU
Kuo WANG
LVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient Voltage
Zhongguo dianli
renewable power gathering system
low voltage ride through
transient overvoltage
short-circuit ratio
title LVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient Voltage
title_full LVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient Voltage
title_fullStr LVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient Voltage
title_full_unstemmed LVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient Voltage
title_short LVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient Voltage
title_sort lvrt reactive current index of renewable units based on the constraints of transient voltage
topic renewable power gathering system
low voltage ride through
transient overvoltage
short-circuit ratio
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202111041
work_keys_str_mv AT huiliu lvrtreactivecurrentindexofrenewableunitsbasedontheconstraintsoftransientvoltage
AT kuowang lvrtreactivecurrentindexofrenewableunitsbasedontheconstraintsoftransientvoltage