Cataract Surgery Results of New Lens Implantation “Synthesis”

Purpose. Analysis of the cataract surgery visual outcomes and advantages of intraocular lens Synthesis SIPY.Material and methods. We have operated 43 eyes with cataract (38 patients) using Synthesis SIPY lens. Non-corrected visual acuity was 0.13 ± 0.08, best corrected visual acuity (BCVA) was 0.36...

Full description

Saved in:
Bibliographic Details
Main Authors: E. A. Ivachev, I. P. Denisova, E. V. Anisimova, A. Yu. Krasnova
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2023-01-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/1982
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849774072405164032
author E. A. Ivachev
I. P. Denisova
E. V. Anisimova
A. Yu. Krasnova
author_facet E. A. Ivachev
I. P. Denisova
E. V. Anisimova
A. Yu. Krasnova
author_sort E. A. Ivachev
collection DOAJ
description Purpose. Analysis of the cataract surgery visual outcomes and advantages of intraocular lens Synthesis SIPY.Material and methods. We have operated 43 eyes with cataract (38 patients) using Synthesis SIPY lens. Non-corrected visual acuity was 0.13 ± 0.08, best corrected visual acuity (BCVA) was 0.36 ± 0.1.Results. Following 7 months, secondary cataract was not detected in any patient, what explain the actuality of square edge optical part on 360° of perimeter. The lens is inserted in cartridge in factory sterile conditions which exclude the contact between lens and environment, reduce the risk of incorrect inserting of the lens in cartridge following pinching by the cartridge flaps and, subsequently, the haptic tearing off. This complex “lens-cartridge” excludes the damage of haptics and optic parts, which can occur in using other IOLs during the removal of the lens from the vial and placing it in the groove of the cartridge. Position of cartridge in injector centralizes the cartridge tunnel for the Accuject Pro injector plunger, thereby reducing the risk of pinching the rubber tip of the IOL haptic plunger during implantation. The diameter of the cartridge tip allows the IOL to be implanted through a 1.6 mm tunnel. The uncorrected visual acuity after surgery was 0.6 ± 0.28. The best corrected visual acuity was 0.78 ± 0.24.Conclusions. The Synthesis SIPY lens has a number of advantages: factory installation of the lens into the cartridge and compatibility of the cartridge with the Accuject Pro injector prevent damage to the IOL; Implantation of the Synthesis SIPY lens is possible through the 1.6 mm corneal tunnel; high diopter ranges from -10.0D to + 40.0D allows for maximum visual results.
format Article
id doaj-art-2d31fe11f1f849b08896b1f7c061476b
institution DOAJ
issn 1816-5095
2500-0845
language Russian
publishDate 2023-01-01
publisher Ophthalmology Publishing Group
record_format Article
series Oftalʹmologiâ
spelling doaj-art-2d31fe11f1f849b08896b1f7c061476b2025-08-20T03:01:51ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452023-01-0119475375810.18008/1816-5095-2022-4-753-758968Cataract Surgery Results of New Lens Implantation “Synthesis”E. A. Ivachev0I. P. Denisova1E. V. Anisimova2A. Yu. Krasnova3Departmental Clinical Hospital at the station Penza of JSC “Russian Railways”; Medical Institute, Penza State UniversityDepartmental Clinical Hospital at the station Penza of JSC “Russian Railways”Departmental Clinical Hospital at the station Penza of JSC “Russian Railways”Medical Institute, Penza State UniversityPurpose. Analysis of the cataract surgery visual outcomes and advantages of intraocular lens Synthesis SIPY.Material and methods. We have operated 43 eyes with cataract (38 patients) using Synthesis SIPY lens. Non-corrected visual acuity was 0.13 ± 0.08, best corrected visual acuity (BCVA) was 0.36 ± 0.1.Results. Following 7 months, secondary cataract was not detected in any patient, what explain the actuality of square edge optical part on 360° of perimeter. The lens is inserted in cartridge in factory sterile conditions which exclude the contact between lens and environment, reduce the risk of incorrect inserting of the lens in cartridge following pinching by the cartridge flaps and, subsequently, the haptic tearing off. This complex “lens-cartridge” excludes the damage of haptics and optic parts, which can occur in using other IOLs during the removal of the lens from the vial and placing it in the groove of the cartridge. Position of cartridge in injector centralizes the cartridge tunnel for the Accuject Pro injector plunger, thereby reducing the risk of pinching the rubber tip of the IOL haptic plunger during implantation. The diameter of the cartridge tip allows the IOL to be implanted through a 1.6 mm tunnel. The uncorrected visual acuity after surgery was 0.6 ± 0.28. The best corrected visual acuity was 0.78 ± 0.24.Conclusions. The Synthesis SIPY lens has a number of advantages: factory installation of the lens into the cartridge and compatibility of the cartridge with the Accuject Pro injector prevent damage to the IOL; Implantation of the Synthesis SIPY lens is possible through the 1.6 mm corneal tunnel; high diopter ranges from -10.0D to + 40.0D allows for maximum visual results.https://www.ophthalmojournal.com/opht/article/view/1982intraocular lenscataractpseudophakiaphacoemulsificationsynthesis sipy
spellingShingle E. A. Ivachev
I. P. Denisova
E. V. Anisimova
A. Yu. Krasnova
Cataract Surgery Results of New Lens Implantation “Synthesis”
Oftalʹmologiâ
intraocular lens
cataract
pseudophakia
phacoemulsification
synthesis sipy
title Cataract Surgery Results of New Lens Implantation “Synthesis”
title_full Cataract Surgery Results of New Lens Implantation “Synthesis”
title_fullStr Cataract Surgery Results of New Lens Implantation “Synthesis”
title_full_unstemmed Cataract Surgery Results of New Lens Implantation “Synthesis”
title_short Cataract Surgery Results of New Lens Implantation “Synthesis”
title_sort cataract surgery results of new lens implantation synthesis
topic intraocular lens
cataract
pseudophakia
phacoemulsification
synthesis sipy
url https://www.ophthalmojournal.com/opht/article/view/1982
work_keys_str_mv AT eaivachev cataractsurgeryresultsofnewlensimplantationsynthesis
AT ipdenisova cataractsurgeryresultsofnewlensimplantationsynthesis
AT evanisimova cataractsurgeryresultsofnewlensimplantationsynthesis
AT ayukrasnova cataractsurgeryresultsofnewlensimplantationsynthesis