A Field Calibration Method for UHF Partial Discharge On-line Monitoring System Based on Cross-check Algorithm

Partial discharge (PD) on-line monitoring device plays an important role in comprehensive perception and intelligent diagnosis of equipment conditions. Affected by the operational environment, manufacturing technology and other factors, the on-line PD sensors are deteriorated in performance with the...

Full description

Saved in:
Bibliographic Details
Main Authors: Nan LI, Songyuan LI, Xuejun SHANG, Bowen GUO, Lin LI, Guoqiang ZU, Kai HOU
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2022-04-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202110058
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850053982844616704
author Nan LI
Songyuan LI
Xuejun SHANG
Bowen GUO
Lin LI
Guoqiang ZU
Kai HOU
author_facet Nan LI
Songyuan LI
Xuejun SHANG
Bowen GUO
Lin LI
Guoqiang ZU
Kai HOU
author_sort Nan LI
collection DOAJ
description Partial discharge (PD) on-line monitoring device plays an important role in comprehensive perception and intelligent diagnosis of equipment conditions. Affected by the operational environment, manufacturing technology and other factors, the on-line PD sensors are deteriorated in performance with the increase of their service time, the sensors’ calibration is thus imperative. An optimized field calibration method is proposed for the internal ultrahigh frequency partial discharge (UHF-PD) sensors of on-line PD monitoring system. Firstly, the influencing factors on the field calibration of the UHF-PD on-line monitoring system are analyzed from three aspects including sensors’ working features, installation location and signal transmission attenuation properties. Then, a novel cross-check method is proposed based on the traditional GIGRE method. Through horizontal comparison between different phases and mirror comparison between input/output signals, the effects of absolute-value check on the accuracy of sensor’s calibration is significantly decreased, thus improving the overall calibration efficiency. Finally, the proposed method was applied in a 500 kV substation for field calibration of the UHF-PD on-line monitoring system, and identified three typical defects, including the degraded sensors’ sensitivity, unreasonable sensors arrangement and faulted acquisition board. The results verified the effectiveness and feasibility of the proposed method.
format Article
id doaj-art-2cafc47f3a974813a337c9b37cf2024c
institution DOAJ
issn 1004-9649
language zho
publishDate 2022-04-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-2cafc47f3a974813a337c9b37cf2024c2025-08-20T02:52:24ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492022-04-0155410010710.11930/j.issn.1004-9649.202110058zgdl-55-3-linanA Field Calibration Method for UHF Partial Discharge On-line Monitoring System Based on Cross-check AlgorithmNan LI0Songyuan LI1Xuejun SHANG2Bowen GUO3Lin LI4Guoqiang ZU5Kai HOU6School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, ChinaElectric Power Research Institute, State Grid Tianjin Electric Power Company, Tianjin 300384, ChinaElectric Power Research Institute, State Grid Tianjin Electric Power Company, Tianjin 300384, ChinaElectric Power Research Institute, State Grid Tianjin Electric Power Company, Tianjin 300384, ChinaElectric Power Research Institute, State Grid Tianjin Electric Power Company, Tianjin 300384, ChinaElectric Power Research Institute, State Grid Tianjin Electric Power Company, Tianjin 300384, ChinaSchool of Electrical and Information Engineering, Tianjin University, Tianjin 300072, ChinaPartial discharge (PD) on-line monitoring device plays an important role in comprehensive perception and intelligent diagnosis of equipment conditions. Affected by the operational environment, manufacturing technology and other factors, the on-line PD sensors are deteriorated in performance with the increase of their service time, the sensors’ calibration is thus imperative. An optimized field calibration method is proposed for the internal ultrahigh frequency partial discharge (UHF-PD) sensors of on-line PD monitoring system. Firstly, the influencing factors on the field calibration of the UHF-PD on-line monitoring system are analyzed from three aspects including sensors’ working features, installation location and signal transmission attenuation properties. Then, a novel cross-check method is proposed based on the traditional GIGRE method. Through horizontal comparison between different phases and mirror comparison between input/output signals, the effects of absolute-value check on the accuracy of sensor’s calibration is significantly decreased, thus improving the overall calibration efficiency. Finally, the proposed method was applied in a 500 kV substation for field calibration of the UHF-PD on-line monitoring system, and identified three typical defects, including the degraded sensors’ sensitivity, unreasonable sensors arrangement and faulted acquisition board. The results verified the effectiveness and feasibility of the proposed method.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202110058uhf-pd on-line monitoring systemfield calibrationlean evaluationcross-checkidentification of typical defects
spellingShingle Nan LI
Songyuan LI
Xuejun SHANG
Bowen GUO
Lin LI
Guoqiang ZU
Kai HOU
A Field Calibration Method for UHF Partial Discharge On-line Monitoring System Based on Cross-check Algorithm
Zhongguo dianli
uhf-pd on-line monitoring system
field calibration
lean evaluation
cross-check
identification of typical defects
title A Field Calibration Method for UHF Partial Discharge On-line Monitoring System Based on Cross-check Algorithm
title_full A Field Calibration Method for UHF Partial Discharge On-line Monitoring System Based on Cross-check Algorithm
title_fullStr A Field Calibration Method for UHF Partial Discharge On-line Monitoring System Based on Cross-check Algorithm
title_full_unstemmed A Field Calibration Method for UHF Partial Discharge On-line Monitoring System Based on Cross-check Algorithm
title_short A Field Calibration Method for UHF Partial Discharge On-line Monitoring System Based on Cross-check Algorithm
title_sort field calibration method for uhf partial discharge on line monitoring system based on cross check algorithm
topic uhf-pd on-line monitoring system
field calibration
lean evaluation
cross-check
identification of typical defects
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202110058
work_keys_str_mv AT nanli afieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT songyuanli afieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT xuejunshang afieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT bowenguo afieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT linli afieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT guoqiangzu afieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT kaihou afieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT nanli fieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT songyuanli fieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT xuejunshang fieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT bowenguo fieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT linli fieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT guoqiangzu fieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm
AT kaihou fieldcalibrationmethodforuhfpartialdischargeonlinemonitoringsystembasedoncrosscheckalgorithm