Research on Unstable Heating Test of Multi-Split Air-condition (Heat Pump) Unit
Seasonal performance evaluation index is taken as the direction to evaluate multi-split air-condition (heat pump) units (Hereinafter referred to as: VRF) in the future. The challenge on unstable heating performance test for VRF unit is discussed when seasonal performance evaluation index is used. Ad...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2013-01-01
|
| Series: | Zhileng xuebao |
| Subjects: | |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2013.06.069 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850071817154199552 |
|---|---|
| author | Shi Min Zhong Yu Zhang Xiuping |
| author_facet | Shi Min Zhong Yu Zhang Xiuping |
| author_sort | Shi Min |
| collection | DOAJ |
| description | Seasonal performance evaluation index is taken as the direction to evaluate multi-split air-condition (heat pump) units (Hereinafter referred to as: VRF) in the future. The challenge on unstable heating performance test for VRF unit is discussed when seasonal performance evaluation index is used. Advantages and disadvantages of unstable heating performance test methods in relevant standards are analyzed. The conclusion indicates that the unstable heating performance test methods in EN and ISO standards reflect the heating performance of VRF units more objectively, and are with good operability and repeatability. Potential effect of the unstable heating performance test method in EN and ISO standards on the development of VRF in China is investigated. The outline and issues of Chinese unstable heating performance test method for VRF units are suggested. |
| format | Article |
| id | doaj-art-2caf9ed4536040098cabf446dd907b59 |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2013-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-2caf9ed4536040098cabf446dd907b592025-08-20T02:47:13ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392013-01-013466515984Research on Unstable Heating Test of Multi-Split Air-condition (Heat Pump) UnitShi MinZhong YuZhang XiupingSeasonal performance evaluation index is taken as the direction to evaluate multi-split air-condition (heat pump) units (Hereinafter referred to as: VRF) in the future. The challenge on unstable heating performance test for VRF unit is discussed when seasonal performance evaluation index is used. Advantages and disadvantages of unstable heating performance test methods in relevant standards are analyzed. The conclusion indicates that the unstable heating performance test methods in EN and ISO standards reflect the heating performance of VRF units more objectively, and are with good operability and repeatability. Potential effect of the unstable heating performance test method in EN and ISO standards on the development of VRF in China is investigated. The outline and issues of Chinese unstable heating performance test method for VRF units are suggested.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2013.06.069multi-split air-condition (heat pump) unitheatingperformance testunstable |
| spellingShingle | Shi Min Zhong Yu Zhang Xiuping Research on Unstable Heating Test of Multi-Split Air-condition (Heat Pump) Unit Zhileng xuebao multi-split air-condition (heat pump) unit heating performance test unstable |
| title | Research on Unstable Heating Test of Multi-Split Air-condition (Heat Pump) Unit |
| title_full | Research on Unstable Heating Test of Multi-Split Air-condition (Heat Pump) Unit |
| title_fullStr | Research on Unstable Heating Test of Multi-Split Air-condition (Heat Pump) Unit |
| title_full_unstemmed | Research on Unstable Heating Test of Multi-Split Air-condition (Heat Pump) Unit |
| title_short | Research on Unstable Heating Test of Multi-Split Air-condition (Heat Pump) Unit |
| title_sort | research on unstable heating test of multi split air condition heat pump unit |
| topic | multi-split air-condition (heat pump) unit heating performance test unstable |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2013.06.069 |
| work_keys_str_mv | AT shimin researchonunstableheatingtestofmultisplitairconditionheatpumpunit AT zhongyu researchonunstableheatingtestofmultisplitairconditionheatpumpunit AT zhangxiuping researchonunstableheatingtestofmultisplitairconditionheatpumpunit |