Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits

<p>Energy-dispersive X-ray fluorescence (ED-XRF) is a versatile non-destructive technique to evaluate elemental composition of atmospheric particulate matter (PM) without the need for sample preparation and with high potentiality in source apportionment studies. It is usually applied on Teflon...

Full description

Saved in:
Bibliographic Details
Main Authors: F. Unga, G. Calzolai, M. Chiari, E. Cuccia, C. Colombi, M. Franciosa, A. Dinoi, E. Merico, A. Pennetta, N. Gómez-Sánchez, C. Mapelli, S. Pareti, C. Perrino, E. Yubero, D. Contini
Format: Article
Language:English
Published: Copernicus Publications 2025-07-01
Series:Aerosol Research
Online Access:https://ar.copernicus.org/articles/3/405/2025/ar-3-405-2025.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850082732108939264
author F. Unga
G. Calzolai
M. Chiari
E. Cuccia
C. Colombi
M. Franciosa
A. Dinoi
E. Merico
A. Pennetta
N. Gómez-Sánchez
C. Mapelli
S. Pareti
C. Perrino
E. Yubero
D. Contini
author_facet F. Unga
G. Calzolai
M. Chiari
E. Cuccia
C. Colombi
M. Franciosa
A. Dinoi
E. Merico
A. Pennetta
N. Gómez-Sánchez
C. Mapelli
S. Pareti
C. Perrino
E. Yubero
D. Contini
author_sort F. Unga
collection DOAJ
description <p>Energy-dispersive X-ray fluorescence (ED-XRF) is a versatile non-destructive technique to evaluate elemental composition of atmospheric particulate matter (PM) without the need for sample preparation and with high potentiality in source apportionment studies. It is usually applied on Teflon or polycarbonate substrates; however, it would be preferable to use quartz substrates for the possibility to use the same substrate also for carbon detection. In this work an intercomparison among five laboratories on PM<span class="inline-formula"><sub>10</sub></span> samples collected on Teflon and quartz filters was done with the specific purpose of understanding the performance of the ED-XRF technique applied to samples collected on quartz substrates. Limits of detection (LODs) on quartz substrates were significantly larger than those on Teflon for the majority of the elements with the exclusion of Cl, Mn, Cu, and Rb, which had comparable LODs for the two substrates. Repeatability on PM<span class="inline-formula"><sub>10</sub></span> samples collected on quartz and Teflon substrates was comparable and, on average, better than 10 % for the majority of the elements analysed and better than 5 % for several elements. Comparisons of analysis on Teflon filters for 20 elements obtained by the different laboratories were in the range of <span class="inline-formula">±15</span> % of the <span class="inline-formula">1:1</span> line for most of the elements and laboratories. Comparison of measurements on samples collected on quartz and Teflon substrates showed that 17 elements were well correlated (<span class="inline-formula"><i>R</i></span> <span class="inline-formula">&gt;</span> 0.7) with average <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M7" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>C</mi><mi mathvariant="normal">quartz</mi></msub><mo>/</mo><msub><mi>C</mi><mi mathvariant="normal">Teflon</mi></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="68pt" height="16pt" class="svg-formula" dspmath="mathimg" md5hash="f07a43f93de1fdd2f724b9de7d8a0620"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ar-3-405-2025-ie00001.svg" width="68pt" height="16pt" src="ar-3-405-2025-ie00001.png"/></svg:svg></span></span> ratios in the range 0.6 <span class="inline-formula">±</span> 0.1 (for light elements, due to self-absorption effects) to 1.1 <span class="inline-formula">±</span> 0.1 for the majority of the cases. This suggested that reasonable results could be obtained on quartz substrates for 17 elements, including Na, Mg, and Al, using calibration on Teflon and the ratios <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M10" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>C</mi><mi mathvariant="normal">quartz</mi></msub><mo>/</mo><msub><mi>C</mi><mi mathvariant="normal">Teflon</mi></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="68pt" height="16pt" class="svg-formula" dspmath="mathimg" md5hash="46fa2acc0d5c2c220b6f9102497060d4"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ar-3-405-2025-ie00002.svg" width="68pt" height="16pt" src="ar-3-405-2025-ie00002.png"/></svg:svg></span></span> as correction factors. However, these correction factors were dependent on the instrument and method used for the analysis.</p>
format Article
id doaj-art-2ca8b412ddfd48139a7c87aba3e53ad4
institution DOAJ
issn 2940-3391
language English
publishDate 2025-07-01
publisher Copernicus Publications
record_format Article
series Aerosol Research
spelling doaj-art-2ca8b412ddfd48139a7c87aba3e53ad42025-08-20T02:44:28ZengCopernicus PublicationsAerosol Research2940-33912025-07-01340541510.5194/ar-3-405-2025Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limitsF. Unga0G. Calzolai1M. Chiari2E. Cuccia3C. Colombi4M. Franciosa5A. Dinoi6E. Merico7A. Pennetta8N. Gómez-Sánchez9C. Mapelli10S. Pareti11C. Perrino12E. Yubero13D. Contini14Institute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyNational Institute for Nuclear Physics – Florence Division, Sesto Fiorentino (FI), 50019, ItalyNational Institute for Nuclear Physics – Florence Division, Sesto Fiorentino (FI), 50019, ItalyARPA Lombardia, Milan, 20124, ItalyARPA Lombardia, Milan, 20124, ItalyARPA Lombardia, Milan, 20124, ItalyInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyAtmospheric Pollution Laboratory, Miguel Hernández University, Elche, 03202, SpainInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyInstitute of Atmospheric Pollution Research, IIA-CNR, Monterotondo (RM), 00015, ItalyInstitute of Atmospheric Pollution Research, IIA-CNR, Monterotondo (RM), 00015, ItalyAtmospheric Pollution Laboratory, Miguel Hernández University, Elche, 03202, SpainInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, Italy<p>Energy-dispersive X-ray fluorescence (ED-XRF) is a versatile non-destructive technique to evaluate elemental composition of atmospheric particulate matter (PM) without the need for sample preparation and with high potentiality in source apportionment studies. It is usually applied on Teflon or polycarbonate substrates; however, it would be preferable to use quartz substrates for the possibility to use the same substrate also for carbon detection. In this work an intercomparison among five laboratories on PM<span class="inline-formula"><sub>10</sub></span> samples collected on Teflon and quartz filters was done with the specific purpose of understanding the performance of the ED-XRF technique applied to samples collected on quartz substrates. Limits of detection (LODs) on quartz substrates were significantly larger than those on Teflon for the majority of the elements with the exclusion of Cl, Mn, Cu, and Rb, which had comparable LODs for the two substrates. Repeatability on PM<span class="inline-formula"><sub>10</sub></span> samples collected on quartz and Teflon substrates was comparable and, on average, better than 10 % for the majority of the elements analysed and better than 5 % for several elements. Comparisons of analysis on Teflon filters for 20 elements obtained by the different laboratories were in the range of <span class="inline-formula">±15</span> % of the <span class="inline-formula">1:1</span> line for most of the elements and laboratories. Comparison of measurements on samples collected on quartz and Teflon substrates showed that 17 elements were well correlated (<span class="inline-formula"><i>R</i></span> <span class="inline-formula">&gt;</span> 0.7) with average <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M7" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>C</mi><mi mathvariant="normal">quartz</mi></msub><mo>/</mo><msub><mi>C</mi><mi mathvariant="normal">Teflon</mi></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="68pt" height="16pt" class="svg-formula" dspmath="mathimg" md5hash="f07a43f93de1fdd2f724b9de7d8a0620"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ar-3-405-2025-ie00001.svg" width="68pt" height="16pt" src="ar-3-405-2025-ie00001.png"/></svg:svg></span></span> ratios in the range 0.6 <span class="inline-formula">±</span> 0.1 (for light elements, due to self-absorption effects) to 1.1 <span class="inline-formula">±</span> 0.1 for the majority of the cases. This suggested that reasonable results could be obtained on quartz substrates for 17 elements, including Na, Mg, and Al, using calibration on Teflon and the ratios <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M10" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>C</mi><mi mathvariant="normal">quartz</mi></msub><mo>/</mo><msub><mi>C</mi><mi mathvariant="normal">Teflon</mi></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="68pt" height="16pt" class="svg-formula" dspmath="mathimg" md5hash="46fa2acc0d5c2c220b6f9102497060d4"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ar-3-405-2025-ie00002.svg" width="68pt" height="16pt" src="ar-3-405-2025-ie00002.png"/></svg:svg></span></span> as correction factors. However, these correction factors were dependent on the instrument and method used for the analysis.</p>https://ar.copernicus.org/articles/3/405/2025/ar-3-405-2025.pdf
spellingShingle F. Unga
G. Calzolai
M. Chiari
E. Cuccia
C. Colombi
M. Franciosa
A. Dinoi
E. Merico
A. Pennetta
N. Gómez-Sánchez
C. Mapelli
S. Pareti
C. Perrino
E. Yubero
D. Contini
Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits
Aerosol Research
title Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits
title_full Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits
title_fullStr Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits
title_full_unstemmed Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits
title_short Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits
title_sort determination of aerosol composition by ed xrf on teflon and quartz substrates potentialities and limits
url https://ar.copernicus.org/articles/3/405/2025/ar-3-405-2025.pdf
work_keys_str_mv AT funga determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT gcalzolai determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT mchiari determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT ecuccia determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT ccolombi determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT mfranciosa determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT adinoi determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT emerico determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT apennetta determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT ngomezsanchez determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT cmapelli determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT spareti determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT cperrino determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT eyubero determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits
AT dcontini determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits