Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits
<p>Energy-dispersive X-ray fluorescence (ED-XRF) is a versatile non-destructive technique to evaluate elemental composition of atmospheric particulate matter (PM) without the need for sample preparation and with high potentiality in source apportionment studies. It is usually applied on Teflon...
Saved in:
| Main Authors: | , , , , , , , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Copernicus Publications
2025-07-01
|
| Series: | Aerosol Research |
| Online Access: | https://ar.copernicus.org/articles/3/405/2025/ar-3-405-2025.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850082732108939264 |
|---|---|
| author | F. Unga G. Calzolai M. Chiari E. Cuccia C. Colombi M. Franciosa A. Dinoi E. Merico A. Pennetta N. Gómez-Sánchez C. Mapelli S. Pareti C. Perrino E. Yubero D. Contini |
| author_facet | F. Unga G. Calzolai M. Chiari E. Cuccia C. Colombi M. Franciosa A. Dinoi E. Merico A. Pennetta N. Gómez-Sánchez C. Mapelli S. Pareti C. Perrino E. Yubero D. Contini |
| author_sort | F. Unga |
| collection | DOAJ |
| description | <p>Energy-dispersive X-ray fluorescence (ED-XRF) is a versatile non-destructive technique to evaluate elemental composition of atmospheric particulate matter (PM) without the need for sample preparation and with high potentiality in source apportionment studies. It is usually applied on Teflon or polycarbonate substrates; however, it would be preferable to use quartz substrates for the possibility to use the same substrate also for carbon detection. In this work an intercomparison among five laboratories on PM<span class="inline-formula"><sub>10</sub></span> samples collected on Teflon and quartz filters was done with the specific purpose of understanding the performance of the ED-XRF technique applied to samples collected on quartz substrates. Limits of detection (LODs) on quartz substrates were significantly larger than those on Teflon for the majority of the elements with the exclusion of Cl, Mn, Cu, and Rb, which had comparable LODs for the two substrates. Repeatability on PM<span class="inline-formula"><sub>10</sub></span> samples collected on quartz and Teflon substrates was comparable and, on average, better than 10 % for the majority of the elements analysed and better than 5 % for several elements. Comparisons of analysis on Teflon filters for 20 elements obtained by the different laboratories were in the range of <span class="inline-formula">±15</span> % of the <span class="inline-formula">1:1</span> line for most of the elements and laboratories. Comparison of measurements on samples collected on quartz and Teflon substrates showed that 17 elements were well correlated (<span class="inline-formula"><i>R</i></span> <span class="inline-formula">></span> 0.7) with average <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M7" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>C</mi><mi mathvariant="normal">quartz</mi></msub><mo>/</mo><msub><mi>C</mi><mi mathvariant="normal">Teflon</mi></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="68pt" height="16pt" class="svg-formula" dspmath="mathimg" md5hash="f07a43f93de1fdd2f724b9de7d8a0620"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ar-3-405-2025-ie00001.svg" width="68pt" height="16pt" src="ar-3-405-2025-ie00001.png"/></svg:svg></span></span> ratios in the range 0.6 <span class="inline-formula">±</span> 0.1 (for light elements, due to self-absorption effects) to 1.1 <span class="inline-formula">±</span> 0.1 for the majority of the cases. This suggested that reasonable results could be obtained on quartz substrates for 17 elements, including Na, Mg, and Al, using calibration on Teflon and the ratios <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M10" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>C</mi><mi mathvariant="normal">quartz</mi></msub><mo>/</mo><msub><mi>C</mi><mi mathvariant="normal">Teflon</mi></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="68pt" height="16pt" class="svg-formula" dspmath="mathimg" md5hash="46fa2acc0d5c2c220b6f9102497060d4"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ar-3-405-2025-ie00002.svg" width="68pt" height="16pt" src="ar-3-405-2025-ie00002.png"/></svg:svg></span></span> as correction factors. However, these correction factors were dependent on the instrument and method used for the analysis.</p> |
| format | Article |
| id | doaj-art-2ca8b412ddfd48139a7c87aba3e53ad4 |
| institution | DOAJ |
| issn | 2940-3391 |
| language | English |
| publishDate | 2025-07-01 |
| publisher | Copernicus Publications |
| record_format | Article |
| series | Aerosol Research |
| spelling | doaj-art-2ca8b412ddfd48139a7c87aba3e53ad42025-08-20T02:44:28ZengCopernicus PublicationsAerosol Research2940-33912025-07-01340541510.5194/ar-3-405-2025Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limitsF. Unga0G. Calzolai1M. Chiari2E. Cuccia3C. Colombi4M. Franciosa5A. Dinoi6E. Merico7A. Pennetta8N. Gómez-Sánchez9C. Mapelli10S. Pareti11C. Perrino12E. Yubero13D. Contini14Institute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyNational Institute for Nuclear Physics – Florence Division, Sesto Fiorentino (FI), 50019, ItalyNational Institute for Nuclear Physics – Florence Division, Sesto Fiorentino (FI), 50019, ItalyARPA Lombardia, Milan, 20124, ItalyARPA Lombardia, Milan, 20124, ItalyARPA Lombardia, Milan, 20124, ItalyInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyAtmospheric Pollution Laboratory, Miguel Hernández University, Elche, 03202, SpainInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, ItalyInstitute of Atmospheric Pollution Research, IIA-CNR, Monterotondo (RM), 00015, ItalyInstitute of Atmospheric Pollution Research, IIA-CNR, Monterotondo (RM), 00015, ItalyAtmospheric Pollution Laboratory, Miguel Hernández University, Elche, 03202, SpainInstitute of Atmospheric Sciences and Climate, ISAC-CNR, Lecce, 73100, Italy<p>Energy-dispersive X-ray fluorescence (ED-XRF) is a versatile non-destructive technique to evaluate elemental composition of atmospheric particulate matter (PM) without the need for sample preparation and with high potentiality in source apportionment studies. It is usually applied on Teflon or polycarbonate substrates; however, it would be preferable to use quartz substrates for the possibility to use the same substrate also for carbon detection. In this work an intercomparison among five laboratories on PM<span class="inline-formula"><sub>10</sub></span> samples collected on Teflon and quartz filters was done with the specific purpose of understanding the performance of the ED-XRF technique applied to samples collected on quartz substrates. Limits of detection (LODs) on quartz substrates were significantly larger than those on Teflon for the majority of the elements with the exclusion of Cl, Mn, Cu, and Rb, which had comparable LODs for the two substrates. Repeatability on PM<span class="inline-formula"><sub>10</sub></span> samples collected on quartz and Teflon substrates was comparable and, on average, better than 10 % for the majority of the elements analysed and better than 5 % for several elements. Comparisons of analysis on Teflon filters for 20 elements obtained by the different laboratories were in the range of <span class="inline-formula">±15</span> % of the <span class="inline-formula">1:1</span> line for most of the elements and laboratories. Comparison of measurements on samples collected on quartz and Teflon substrates showed that 17 elements were well correlated (<span class="inline-formula"><i>R</i></span> <span class="inline-formula">></span> 0.7) with average <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M7" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>C</mi><mi mathvariant="normal">quartz</mi></msub><mo>/</mo><msub><mi>C</mi><mi mathvariant="normal">Teflon</mi></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="68pt" height="16pt" class="svg-formula" dspmath="mathimg" md5hash="f07a43f93de1fdd2f724b9de7d8a0620"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ar-3-405-2025-ie00001.svg" width="68pt" height="16pt" src="ar-3-405-2025-ie00001.png"/></svg:svg></span></span> ratios in the range 0.6 <span class="inline-formula">±</span> 0.1 (for light elements, due to self-absorption effects) to 1.1 <span class="inline-formula">±</span> 0.1 for the majority of the cases. This suggested that reasonable results could be obtained on quartz substrates for 17 elements, including Na, Mg, and Al, using calibration on Teflon and the ratios <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M10" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>C</mi><mi mathvariant="normal">quartz</mi></msub><mo>/</mo><msub><mi>C</mi><mi mathvariant="normal">Teflon</mi></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="68pt" height="16pt" class="svg-formula" dspmath="mathimg" md5hash="46fa2acc0d5c2c220b6f9102497060d4"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ar-3-405-2025-ie00002.svg" width="68pt" height="16pt" src="ar-3-405-2025-ie00002.png"/></svg:svg></span></span> as correction factors. However, these correction factors were dependent on the instrument and method used for the analysis.</p>https://ar.copernicus.org/articles/3/405/2025/ar-3-405-2025.pdf |
| spellingShingle | F. Unga G. Calzolai M. Chiari E. Cuccia C. Colombi M. Franciosa A. Dinoi E. Merico A. Pennetta N. Gómez-Sánchez C. Mapelli S. Pareti C. Perrino E. Yubero D. Contini Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits Aerosol Research |
| title | Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits |
| title_full | Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits |
| title_fullStr | Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits |
| title_full_unstemmed | Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits |
| title_short | Determination of aerosol composition by ED-XRF on Teflon and quartz substrates: potentialities and limits |
| title_sort | determination of aerosol composition by ed xrf on teflon and quartz substrates potentialities and limits |
| url | https://ar.copernicus.org/articles/3/405/2025/ar-3-405-2025.pdf |
| work_keys_str_mv | AT funga determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT gcalzolai determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT mchiari determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT ecuccia determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT ccolombi determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT mfranciosa determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT adinoi determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT emerico determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT apennetta determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT ngomezsanchez determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT cmapelli determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT spareti determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT cperrino determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT eyubero determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits AT dcontini determinationofaerosolcompositionbyedxrfonteflonandquartzsubstratespotentialitiesandlimits |