Cranial Ultrasound in the Management of Hydrocephalus in Newborns: A Case Series

Background: Hydrocephalus in preterm and term newborns is a condition with an important impact on medical care and the neurological development of patients, with high expenditures regarding daily care. Imaging nowadays provides valuable information regarding the aetiology of the condition, and it re...

Full description

Saved in:
Bibliographic Details
Main Authors: Bogdan Florin Gonț, Loredana Mitran, Vlad Dima, Simona Vlădăreanu
Format: Article
Language:English
Published: MDPI AG 2025-03-01
Series:Children
Subjects:
Online Access:https://www.mdpi.com/2227-9067/12/4/419
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850144689652498432
author Bogdan Florin Gonț
Loredana Mitran
Vlad Dima
Simona Vlădăreanu
author_facet Bogdan Florin Gonț
Loredana Mitran
Vlad Dima
Simona Vlădăreanu
author_sort Bogdan Florin Gonț
collection DOAJ
description Background: Hydrocephalus in preterm and term newborns is a condition with an important impact on medical care and the neurological development of patients, with high expenditures regarding daily care. Imaging nowadays provides valuable information regarding the aetiology of the condition, and it represents a great aid in monitoring the development of the patients. Materials and methods: In this article, we present the cases of five patients with hydrocephalus, for which different imaging methods were used to detect and treat the underlying aetiology, emphasizing the cranial ultrasound examination. Results: The results provided valuable information regarding the utility and feasibility of ultrasound. Moreover, Prechtl’s Assessment of General Movements is yet another useful tool, which in correlation with the use of cranial ultrasound can provide good insight regarding the evolution of the affected newborns. The Kurjak Antenatal Neurodevelopmental Test (KANET, KANE Test) comes in handy in the case of prenatal neurological assessments. Conclusions: Ultrasound examination proves to be a worthy tool capable of detecting the aetiology; however, in several cases, a complementary imaging examination might be needed. The therapeutic approach should take into consideration the diverse aetiology of the disease.
format Article
id doaj-art-2c82e03a58b44246a7cbe9a45eee3baa
institution OA Journals
issn 2227-9067
language English
publishDate 2025-03-01
publisher MDPI AG
record_format Article
series Children
spelling doaj-art-2c82e03a58b44246a7cbe9a45eee3baa2025-08-20T02:28:18ZengMDPI AGChildren2227-90672025-03-0112441910.3390/children12040419Cranial Ultrasound in the Management of Hydrocephalus in Newborns: A Case SeriesBogdan Florin Gonț0Loredana Mitran1Vlad Dima2Simona Vlădăreanu3Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, RomaniaENT Department, “Elias” Emergency and University Hospital, 011461 Bucharest, RomaniaNeonatology Department, Obstetrics and Gynecology, Filantropia Clinical Hospital, 011132 Bucharest, RomaniaFaculty of Medicine, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, RomaniaBackground: Hydrocephalus in preterm and term newborns is a condition with an important impact on medical care and the neurological development of patients, with high expenditures regarding daily care. Imaging nowadays provides valuable information regarding the aetiology of the condition, and it represents a great aid in monitoring the development of the patients. Materials and methods: In this article, we present the cases of five patients with hydrocephalus, for which different imaging methods were used to detect and treat the underlying aetiology, emphasizing the cranial ultrasound examination. Results: The results provided valuable information regarding the utility and feasibility of ultrasound. Moreover, Prechtl’s Assessment of General Movements is yet another useful tool, which in correlation with the use of cranial ultrasound can provide good insight regarding the evolution of the affected newborns. The Kurjak Antenatal Neurodevelopmental Test (KANET, KANE Test) comes in handy in the case of prenatal neurological assessments. Conclusions: Ultrasound examination proves to be a worthy tool capable of detecting the aetiology; however, in several cases, a complementary imaging examination might be needed. The therapeutic approach should take into consideration the diverse aetiology of the disease.https://www.mdpi.com/2227-9067/12/4/419hydrocephalusventriculomegalypreterm neonateterm neonatecranial ultrasound
spellingShingle Bogdan Florin Gonț
Loredana Mitran
Vlad Dima
Simona Vlădăreanu
Cranial Ultrasound in the Management of Hydrocephalus in Newborns: A Case Series
Children
hydrocephalus
ventriculomegaly
preterm neonate
term neonate
cranial ultrasound
title Cranial Ultrasound in the Management of Hydrocephalus in Newborns: A Case Series
title_full Cranial Ultrasound in the Management of Hydrocephalus in Newborns: A Case Series
title_fullStr Cranial Ultrasound in the Management of Hydrocephalus in Newborns: A Case Series
title_full_unstemmed Cranial Ultrasound in the Management of Hydrocephalus in Newborns: A Case Series
title_short Cranial Ultrasound in the Management of Hydrocephalus in Newborns: A Case Series
title_sort cranial ultrasound in the management of hydrocephalus in newborns a case series
topic hydrocephalus
ventriculomegaly
preterm neonate
term neonate
cranial ultrasound
url https://www.mdpi.com/2227-9067/12/4/419
work_keys_str_mv AT bogdanfloringont cranialultrasoundinthemanagementofhydrocephalusinnewbornsacaseseries
AT loredanamitran cranialultrasoundinthemanagementofhydrocephalusinnewbornsacaseseries
AT vladdima cranialultrasoundinthemanagementofhydrocephalusinnewbornsacaseseries
AT simonavladareanu cranialultrasoundinthemanagementofhydrocephalusinnewbornsacaseseries