Photon counting detector CTA for prostate artery embolization pre-procedure planning and intra-procedural guidance

Abstract Background Prostate artery embolization (PAE) requires a careful understanding of pelvic arterial anatomy and identifying prostatic artery variants. Pre-procedure CTA and intra-procedural cone beam CT are traditional means of planning and performing PAE, with the latter providing guidance f...

Full description

Saved in:
Bibliographic Details
Main Authors: Paul Yousif, Forrest Linch, Prabhakar Rajiah, Jeremy D. Collins, Christopher P. Favazza, Andrea Ferrero, Michael Jundt, Scott Thompson
Format: Article
Language:English
Published: SpringerOpen 2025-06-01
Series:CVIR Endovascular
Subjects:
Online Access:https://doi.org/10.1186/s42155-025-00567-6
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850207301769625600
author Paul Yousif
Forrest Linch
Prabhakar Rajiah
Jeremy D. Collins
Christopher P. Favazza
Andrea Ferrero
Michael Jundt
Scott Thompson
author_facet Paul Yousif
Forrest Linch
Prabhakar Rajiah
Jeremy D. Collins
Christopher P. Favazza
Andrea Ferrero
Michael Jundt
Scott Thompson
author_sort Paul Yousif
collection DOAJ
description Abstract Background Prostate artery embolization (PAE) requires a careful understanding of pelvic arterial anatomy and identifying prostatic artery variants. Pre-procedure CTA and intra-procedural cone beam CT are traditional means of planning and performing PAE, with the latter providing guidance for embolization. Photon counting detector (PCD) CT enables ultra-high spatial resolution (UHR) whole-body imaging. For PAE, we obtain a single UHR PCD CT arterial phase acquisition, which provides both detailed pre-procedure pelvic arterial anatomic information and a dataset for 2D (angiographic) to 3D (CTA) fusion for intra-procedural guidance during PAE using embolization guidance software in the angiography suite. Case presentations In six patients who underwent technically successful PAE via a left transradial approach, the pre-procedure diagnostic UHR pelvic PCD prostate CTA delineated bilateral prostatic artery origins and course in all cases, as confirmed with conventional angiograms. Further, registration of the UHR PCD CTA for embolization guidance was successful in all cases, augmenting vessel selection. No complication occurred. Conclusion UHR PCD CTA is a novel imaging technology that can provide detailed prostate arterial anatomic information for pre-procedure PAE planning. Further, this same UHR PCD CTA dataset can be used for intra-procedural embolization guidance using commercially available embolization guidance software.
format Article
id doaj-art-2ba2caa156eb43d5b6b80e26b1d14ca4
institution OA Journals
issn 2520-8934
language English
publishDate 2025-06-01
publisher SpringerOpen
record_format Article
series CVIR Endovascular
spelling doaj-art-2ba2caa156eb43d5b6b80e26b1d14ca42025-08-20T02:10:34ZengSpringerOpenCVIR Endovascular2520-89342025-06-01811710.1186/s42155-025-00567-6Photon counting detector CTA for prostate artery embolization pre-procedure planning and intra-procedural guidancePaul Yousif0Forrest Linch1Prabhakar Rajiah2Jeremy D. Collins3Christopher P. Favazza4Andrea Ferrero5Michael Jundt6Scott Thompson7Department of Radiology, Mayo ClinicDepartment of Radiology, Mayo ClinicDepartment of Radiology, Mayo ClinicDepartment of Radiology, Mayo ClinicDepartment of Radiology, Mayo ClinicDepartment of Radiology, Mayo ClinicDepartment of Radiology, Mayo ClinicDepartment of Radiology, Mayo ClinicAbstract Background Prostate artery embolization (PAE) requires a careful understanding of pelvic arterial anatomy and identifying prostatic artery variants. Pre-procedure CTA and intra-procedural cone beam CT are traditional means of planning and performing PAE, with the latter providing guidance for embolization. Photon counting detector (PCD) CT enables ultra-high spatial resolution (UHR) whole-body imaging. For PAE, we obtain a single UHR PCD CT arterial phase acquisition, which provides both detailed pre-procedure pelvic arterial anatomic information and a dataset for 2D (angiographic) to 3D (CTA) fusion for intra-procedural guidance during PAE using embolization guidance software in the angiography suite. Case presentations In six patients who underwent technically successful PAE via a left transradial approach, the pre-procedure diagnostic UHR pelvic PCD prostate CTA delineated bilateral prostatic artery origins and course in all cases, as confirmed with conventional angiograms. Further, registration of the UHR PCD CTA for embolization guidance was successful in all cases, augmenting vessel selection. No complication occurred. Conclusion UHR PCD CTA is a novel imaging technology that can provide detailed prostate arterial anatomic information for pre-procedure PAE planning. Further, this same UHR PCD CTA dataset can be used for intra-procedural embolization guidance using commercially available embolization guidance software.https://doi.org/10.1186/s42155-025-00567-6Photon Counting Detector Computed TomographyPCD CTProstate artery embolizationBenign prostatic hyperplasiaLower urinary tract symptomsEmbolization guidance
spellingShingle Paul Yousif
Forrest Linch
Prabhakar Rajiah
Jeremy D. Collins
Christopher P. Favazza
Andrea Ferrero
Michael Jundt
Scott Thompson
Photon counting detector CTA for prostate artery embolization pre-procedure planning and intra-procedural guidance
CVIR Endovascular
Photon Counting Detector Computed Tomography
PCD CT
Prostate artery embolization
Benign prostatic hyperplasia
Lower urinary tract symptoms
Embolization guidance
title Photon counting detector CTA for prostate artery embolization pre-procedure planning and intra-procedural guidance
title_full Photon counting detector CTA for prostate artery embolization pre-procedure planning and intra-procedural guidance
title_fullStr Photon counting detector CTA for prostate artery embolization pre-procedure planning and intra-procedural guidance
title_full_unstemmed Photon counting detector CTA for prostate artery embolization pre-procedure planning and intra-procedural guidance
title_short Photon counting detector CTA for prostate artery embolization pre-procedure planning and intra-procedural guidance
title_sort photon counting detector cta for prostate artery embolization pre procedure planning and intra procedural guidance
topic Photon Counting Detector Computed Tomography
PCD CT
Prostate artery embolization
Benign prostatic hyperplasia
Lower urinary tract symptoms
Embolization guidance
url https://doi.org/10.1186/s42155-025-00567-6
work_keys_str_mv AT paulyousif photoncountingdetectorctaforprostatearteryembolizationpreprocedureplanningandintraproceduralguidance
AT forrestlinch photoncountingdetectorctaforprostatearteryembolizationpreprocedureplanningandintraproceduralguidance
AT prabhakarrajiah photoncountingdetectorctaforprostatearteryembolizationpreprocedureplanningandintraproceduralguidance
AT jeremydcollins photoncountingdetectorctaforprostatearteryembolizationpreprocedureplanningandintraproceduralguidance
AT christopherpfavazza photoncountingdetectorctaforprostatearteryembolizationpreprocedureplanningandintraproceduralguidance
AT andreaferrero photoncountingdetectorctaforprostatearteryembolizationpreprocedureplanningandintraproceduralguidance
AT michaeljundt photoncountingdetectorctaforprostatearteryembolizationpreprocedureplanningandintraproceduralguidance
AT scottthompson photoncountingdetectorctaforprostatearteryembolizationpreprocedureplanningandintraproceduralguidance