Benchmark VERCORS 2022: blind prediction of time-dependent behavior of concrete containment building with low and high-fidelity models
The VERCORS program aims to acquire an extensive experimental dataset collected to provide a solid basis for numerical modeling of concrete containment buildings (CCBs). In order to cover the entire life-span of a real containment, the measurements are done on 3× smaller mock-up which leads to 9-fo...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Czech Technical University in Prague
2023-07-01
|
| Series: | Acta Polytechnica CTU Proceedings |
| Subjects: | |
| Online Access: | https://ojs.cvut.cz/ojs/index.php/APP/article/view/9219 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850108147519193088 |
|---|---|
| author | Štěpán Krátký Petr Havlásek |
| author_facet | Štěpán Krátký Petr Havlásek |
| author_sort | Štěpán Krátký |
| collection | DOAJ |
| description |
The VERCORS program aims to acquire an extensive experimental dataset collected to provide a solid basis for numerical modeling of concrete containment buildings (CCBs). In order to cover the entire life-span of a real containment, the measurements are done on 3× smaller mock-up which leads to 9-fold acceleration of all processes related to drying. The goal for the participants of the third VERCORS benchmark was to predict the behaviour of the CCB based on standard laboratory measurements on VERCORS concrete. The previous paper [1] presented the calibration procedure of material models for moisture transport and time-dependent behavior of concrete and summarized the results obtained with a computationally efficient low-fidelity model (LFM). The present paper compares the responses of the LFM and a high-fidelity model (HFM) with a detailed geometry of the entire containment and presents a comparison with the experimental data collected over the last 8 years on the VERCORS mockup.
|
| format | Article |
| id | doaj-art-2ab28f9807054aa1bd24e5ec8e696443 |
| institution | OA Journals |
| issn | 2336-5382 |
| language | English |
| publishDate | 2023-07-01 |
| publisher | Czech Technical University in Prague |
| record_format | Article |
| series | Acta Polytechnica CTU Proceedings |
| spelling | doaj-art-2ab28f9807054aa1bd24e5ec8e6964432025-08-20T02:38:26ZengCzech Technical University in PragueActa Polytechnica CTU Proceedings2336-53822023-07-014010.14311/APP.2023.40.0048Benchmark VERCORS 2022: blind prediction of time-dependent behavior of concrete containment building with low and high-fidelity modelsŠtěpán Krátký0Petr Havlásek1Czech Technical University in Prague, Faculty of Civil Engineering, Department of Mechanics, Thákurova 7, 166 29 Prague 6, Czech RepublicCzech Technical University in Prague, Faculty of Civil Engineering, Department of Mechanics, Thákurova 7, 166 29 Prague 6, Czech Republic The VERCORS program aims to acquire an extensive experimental dataset collected to provide a solid basis for numerical modeling of concrete containment buildings (CCBs). In order to cover the entire life-span of a real containment, the measurements are done on 3× smaller mock-up which leads to 9-fold acceleration of all processes related to drying. The goal for the participants of the third VERCORS benchmark was to predict the behaviour of the CCB based on standard laboratory measurements on VERCORS concrete. The previous paper [1] presented the calibration procedure of material models for moisture transport and time-dependent behavior of concrete and summarized the results obtained with a computationally efficient low-fidelity model (LFM). The present paper compares the responses of the LFM and a high-fidelity model (HFM) with a detailed geometry of the entire containment and presents a comparison with the experimental data collected over the last 8 years on the VERCORS mockup. https://ojs.cvut.cz/ojs/index.php/APP/article/view/9219concretecreepshrinkagedryingcyclic temperaturemodeling |
| spellingShingle | Štěpán Krátký Petr Havlásek Benchmark VERCORS 2022: blind prediction of time-dependent behavior of concrete containment building with low and high-fidelity models Acta Polytechnica CTU Proceedings concrete creep shrinkage drying cyclic temperature modeling |
| title | Benchmark VERCORS 2022: blind prediction of time-dependent behavior of concrete containment building with low and high-fidelity models |
| title_full | Benchmark VERCORS 2022: blind prediction of time-dependent behavior of concrete containment building with low and high-fidelity models |
| title_fullStr | Benchmark VERCORS 2022: blind prediction of time-dependent behavior of concrete containment building with low and high-fidelity models |
| title_full_unstemmed | Benchmark VERCORS 2022: blind prediction of time-dependent behavior of concrete containment building with low and high-fidelity models |
| title_short | Benchmark VERCORS 2022: blind prediction of time-dependent behavior of concrete containment building with low and high-fidelity models |
| title_sort | benchmark vercors 2022 blind prediction of time dependent behavior of concrete containment building with low and high fidelity models |
| topic | concrete creep shrinkage drying cyclic temperature modeling |
| url | https://ojs.cvut.cz/ojs/index.php/APP/article/view/9219 |
| work_keys_str_mv | AT stepankratky benchmarkvercors2022blindpredictionoftimedependentbehaviorofconcretecontainmentbuildingwithlowandhighfidelitymodels AT petrhavlasek benchmarkvercors2022blindpredictionoftimedependentbehaviorofconcretecontainmentbuildingwithlowandhighfidelitymodels |