Study on the influence of fire source location on cable tunnel detection and alarm system

In order to study the fire detection method of cable tunnel. We carried out physical experiments in the cable tunnel test section, using the heater pyrolyze PVC so that its pyrolysis as the ignition source obtained a total of 17 fire source location points in the horizontal and vertical directions o...

Full description

Saved in:
Bibliographic Details
Main Authors: Lei Lei, Zeyu Wang, Zihao Liang
Format: Article
Language:English
Published: Elsevier 2024-12-01
Series:Case Studies in Thermal Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X24015387
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850168357834194944
author Lei Lei
Zeyu Wang
Zihao Liang
author_facet Lei Lei
Zeyu Wang
Zihao Liang
author_sort Lei Lei
collection DOAJ
description In order to study the fire detection method of cable tunnel. We carried out physical experiments in the cable tunnel test section, using the heater pyrolyze PVC so that its pyrolysis as the ignition source obtained a total of 17 fire source location points in the horizontal and vertical directions of seven different fire detectors, and only processed the response time data of the alarm detector obtained the response time and the analysis results were drawn. With the increase of the distance from the fire source, the response time of each type of detector increases in different forms. It is found that the detection distance of the grating fiber temperature sensor is shorter, and the response time near the fire source is more stable. The detection performance of the point pyrolytic particle detector is more affected by the detection distance, which is advantageous for the detection point to have better response performance. The intelligent active suction detector is also affected by the detection distance, which is less affected than the point detector, the response time curve is more stable, and the detection performance is better at each test point. Clc number: X Document Identification Code; A.
format Article
id doaj-art-28b7c844c4184b4fb091a435084c8b4a
institution OA Journals
issn 2214-157X
language English
publishDate 2024-12-01
publisher Elsevier
record_format Article
series Case Studies in Thermal Engineering
spelling doaj-art-28b7c844c4184b4fb091a435084c8b4a2025-08-20T02:20:58ZengElsevierCase Studies in Thermal Engineering2214-157X2024-12-016410550710.1016/j.csite.2024.105507Study on the influence of fire source location on cable tunnel detection and alarm systemLei Lei0Zeyu Wang1Zihao Liang2China People's Police University, School of Fire Protection Engineering, Hebei, Langfang, 065000, China; University of Science and Technology of China, Anhui, Heifei, 230000, China; Corresponding author. China People's Police University, School of Fire Protection Engineering, Hebei, Langfang, 065000, China.China People's Police University, School of Fire Protection Engineering, Hebei, Langfang, 065000, ChinaRizhao Marine Engineering College, Shangdong, Rizhao, 276825, ChinaIn order to study the fire detection method of cable tunnel. We carried out physical experiments in the cable tunnel test section, using the heater pyrolyze PVC so that its pyrolysis as the ignition source obtained a total of 17 fire source location points in the horizontal and vertical directions of seven different fire detectors, and only processed the response time data of the alarm detector obtained the response time and the analysis results were drawn. With the increase of the distance from the fire source, the response time of each type of detector increases in different forms. It is found that the detection distance of the grating fiber temperature sensor is shorter, and the response time near the fire source is more stable. The detection performance of the point pyrolytic particle detector is more affected by the detection distance, which is advantageous for the detection point to have better response performance. The intelligent active suction detector is also affected by the detection distance, which is less affected than the point detector, the response time curve is more stable, and the detection performance is better at each test point. Clc number: X Document Identification Code; A.http://www.sciencedirect.com/science/article/pii/S2214157X24015387Cable tunnelFire source locationIntelligent active suction detection methodResponse time
spellingShingle Lei Lei
Zeyu Wang
Zihao Liang
Study on the influence of fire source location on cable tunnel detection and alarm system
Case Studies in Thermal Engineering
Cable tunnel
Fire source location
Intelligent active suction detection method
Response time
title Study on the influence of fire source location on cable tunnel detection and alarm system
title_full Study on the influence of fire source location on cable tunnel detection and alarm system
title_fullStr Study on the influence of fire source location on cable tunnel detection and alarm system
title_full_unstemmed Study on the influence of fire source location on cable tunnel detection and alarm system
title_short Study on the influence of fire source location on cable tunnel detection and alarm system
title_sort study on the influence of fire source location on cable tunnel detection and alarm system
topic Cable tunnel
Fire source location
Intelligent active suction detection method
Response time
url http://www.sciencedirect.com/science/article/pii/S2214157X24015387
work_keys_str_mv AT leilei studyontheinfluenceoffiresourcelocationoncabletunneldetectionandalarmsystem
AT zeyuwang studyontheinfluenceoffiresourcelocationoncabletunneldetectionandalarmsystem
AT zihaoliang studyontheinfluenceoffiresourcelocationoncabletunneldetectionandalarmsystem