Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects

Background. The use of echocardiography in intensive care settings impacts decision making. A prerequisite for the use of echocardiography is relative resistance to changes in volume status and levels of positive pressure ventilation (PPV). Studies on indices of diastolic function report conflicting...

Full description

Saved in:
Bibliographic Details
Main Authors: Peter Juhl-Olsen, Christian Alcaraz Frederiksen, Johan Fridolf Hermansen, Carl-Johan Jakobsen, Erik Sloth
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Critical Care Research and Practice
Online Access:http://dx.doi.org/10.1155/2012/703196
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849307776654770176
author Peter Juhl-Olsen
Christian Alcaraz Frederiksen
Johan Fridolf Hermansen
Carl-Johan Jakobsen
Erik Sloth
author_facet Peter Juhl-Olsen
Christian Alcaraz Frederiksen
Johan Fridolf Hermansen
Carl-Johan Jakobsen
Erik Sloth
author_sort Peter Juhl-Olsen
collection DOAJ
description Background. The use of echocardiography in intensive care settings impacts decision making. A prerequisite for the use of echocardiography is relative resistance to changes in volume status and levels of positive pressure ventilation (PPV). Studies on indices of diastolic function report conflicting results with regard to dependence on volume status. Evidence is scarce on PPV. Methods. Ten healthy subjects were exposed to 6 levels of positive end-expiratory pressure (PEEP) and pressure support (PS) following a baseline reading. All ventilator settings were performed at three positions: horizontal, reverse-Trendelenburg, and Trendelenburg. Echocardiography was performed throughout. Results. During spontaneous breathing, early diastolic transmitral velocity () changed with positioning (), whereas early diastolic velocity of the mitral annulus () was independent (). With PPV, and proved preload dependent (). Increases in PEEP, PS, or a combination influenced and in reverse-Trendelenburg- and horizontal positions, but not in the Trendelenburg position. Discussion. The change towards preload dependency of with PPV suggests that PPV increases myocardial preload sensitivity. The susceptibility of and to preload changes during PPV discourages their use in settings of volume shifts or during changes in ventilator settings. Conclusion. Positioning and PPV affect and .
format Article
id doaj-art-28679b0df3f64d1ea7cc0a6839a40dc0
institution Kabale University
issn 2090-1305
2090-1313
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series Critical Care Research and Practice
spelling doaj-art-28679b0df3f64d1ea7cc0a6839a40dc02025-08-20T03:54:38ZengWileyCritical Care Research and Practice2090-13052090-13132012-01-01201210.1155/2012/703196703196Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy SubjectsPeter Juhl-Olsen0Christian Alcaraz Frederiksen1Johan Fridolf Hermansen2Carl-Johan Jakobsen3Erik Sloth4Department of Anaesthesiology and Intensive Care, Aarhus University Hospital, Skejby, Brendstrupgaardsvej 100, 8200 Aarhus N, DenmarkDepartment of Anaesthesiology and Intensive Care, Aarhus University Hospital, Skejby, Brendstrupgaardsvej 100, 8200 Aarhus N, DenmarkDepartment of Anaesthesiology and Intensive Care, Aarhus University Hospital, Skejby, Brendstrupgaardsvej 100, 8200 Aarhus N, DenmarkDepartment of Anaesthesiology and Intensive Care, Aarhus University Hospital, Skejby, Brendstrupgaardsvej 100, 8200 Aarhus N, DenmarkDepartment of Anaesthesiology and Intensive Care, Aarhus University Hospital, Skejby, Brendstrupgaardsvej 100, 8200 Aarhus N, DenmarkBackground. The use of echocardiography in intensive care settings impacts decision making. A prerequisite for the use of echocardiography is relative resistance to changes in volume status and levels of positive pressure ventilation (PPV). Studies on indices of diastolic function report conflicting results with regard to dependence on volume status. Evidence is scarce on PPV. Methods. Ten healthy subjects were exposed to 6 levels of positive end-expiratory pressure (PEEP) and pressure support (PS) following a baseline reading. All ventilator settings were performed at three positions: horizontal, reverse-Trendelenburg, and Trendelenburg. Echocardiography was performed throughout. Results. During spontaneous breathing, early diastolic transmitral velocity () changed with positioning (), whereas early diastolic velocity of the mitral annulus () was independent (). With PPV, and proved preload dependent (). Increases in PEEP, PS, or a combination influenced and in reverse-Trendelenburg- and horizontal positions, but not in the Trendelenburg position. Discussion. The change towards preload dependency of with PPV suggests that PPV increases myocardial preload sensitivity. The susceptibility of and to preload changes during PPV discourages their use in settings of volume shifts or during changes in ventilator settings. Conclusion. Positioning and PPV affect and .http://dx.doi.org/10.1155/2012/703196
spellingShingle Peter Juhl-Olsen
Christian Alcaraz Frederiksen
Johan Fridolf Hermansen
Carl-Johan Jakobsen
Erik Sloth
Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects
Critical Care Research and Practice
title Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects
title_full Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects
title_fullStr Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects
title_full_unstemmed Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects
title_short Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects
title_sort echocardiographic measures of diastolic function are preload dependent during triggered positive pressure ventilation a controlled crossover study in healthy subjects
url http://dx.doi.org/10.1155/2012/703196
work_keys_str_mv AT peterjuhlolsen echocardiographicmeasuresofdiastolicfunctionarepreloaddependentduringtriggeredpositivepressureventilationacontrolledcrossoverstudyinhealthysubjects
AT christianalcarazfrederiksen echocardiographicmeasuresofdiastolicfunctionarepreloaddependentduringtriggeredpositivepressureventilationacontrolledcrossoverstudyinhealthysubjects
AT johanfridolfhermansen echocardiographicmeasuresofdiastolicfunctionarepreloaddependentduringtriggeredpositivepressureventilationacontrolledcrossoverstudyinhealthysubjects
AT carljohanjakobsen echocardiographicmeasuresofdiastolicfunctionarepreloaddependentduringtriggeredpositivepressureventilationacontrolledcrossoverstudyinhealthysubjects
AT eriksloth echocardiographicmeasuresofdiastolicfunctionarepreloaddependentduringtriggeredpositivepressureventilationacontrolledcrossoverstudyinhealthysubjects