Development and Validation of a Complete GATE Model of the Siemens Inveon Trimodal Imaging Platform

This article presents and validates a newly developed GATE model of the Siemens Inveon trimodal imaging platform. Fully incorporating the positron emission tomography (PET), single-photon emission computed tomography (SPECT), and computed tomography (CT) data acquisition subsystems, this model enabl...

Full description

Saved in:
Bibliographic Details
Main Authors: Sanghyeb Lee, Jens Gregor, Dustin Osborne
Format: Article
Language:English
Published: SAGE Publishing 2013-10-01
Series:Molecular Imaging
Online Access:https://doi.org/10.2310/7290.2013.00058
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841564523263164416
author Sanghyeb Lee
Jens Gregor
Dustin Osborne
author_facet Sanghyeb Lee
Jens Gregor
Dustin Osborne
author_sort Sanghyeb Lee
collection DOAJ
description This article presents and validates a newly developed GATE model of the Siemens Inveon trimodal imaging platform. Fully incorporating the positron emission tomography (PET), single-photon emission computed tomography (SPECT), and computed tomography (CT) data acquisition subsystems, this model enables feasibility studies of new imaging applications, the development of reconstruction and correction algorithms, and the creation of a baseline against which experimental results for real data can be compared. Model validation was based on comparing simulation results against both empirical and published data. The PET modality was validated using the NEMA NU-4 standard. Validations of SPECT and CT modalities were based on assessment of model accuracy compared to published and empirical data on the platform. Validation results show good agreement between simulation and empirical data of approximately ± 5%.
format Article
id doaj-art-28150a5f1c024629a3e8904114ee7888
institution Kabale University
issn 1536-0121
language English
publishDate 2013-10-01
publisher SAGE Publishing
record_format Article
series Molecular Imaging
spelling doaj-art-28150a5f1c024629a3e8904114ee78882025-01-02T22:37:55ZengSAGE PublishingMolecular Imaging1536-01212013-10-011210.2310/7290.2013.0005810.2310_7290.2013.00058Development and Validation of a Complete GATE Model of the Siemens Inveon Trimodal Imaging PlatformSanghyeb LeeJens GregorDustin OsborneThis article presents and validates a newly developed GATE model of the Siemens Inveon trimodal imaging platform. Fully incorporating the positron emission tomography (PET), single-photon emission computed tomography (SPECT), and computed tomography (CT) data acquisition subsystems, this model enables feasibility studies of new imaging applications, the development of reconstruction and correction algorithms, and the creation of a baseline against which experimental results for real data can be compared. Model validation was based on comparing simulation results against both empirical and published data. The PET modality was validated using the NEMA NU-4 standard. Validations of SPECT and CT modalities were based on assessment of model accuracy compared to published and empirical data on the platform. Validation results show good agreement between simulation and empirical data of approximately ± 5%.https://doi.org/10.2310/7290.2013.00058
spellingShingle Sanghyeb Lee
Jens Gregor
Dustin Osborne
Development and Validation of a Complete GATE Model of the Siemens Inveon Trimodal Imaging Platform
Molecular Imaging
title Development and Validation of a Complete GATE Model of the Siemens Inveon Trimodal Imaging Platform
title_full Development and Validation of a Complete GATE Model of the Siemens Inveon Trimodal Imaging Platform
title_fullStr Development and Validation of a Complete GATE Model of the Siemens Inveon Trimodal Imaging Platform
title_full_unstemmed Development and Validation of a Complete GATE Model of the Siemens Inveon Trimodal Imaging Platform
title_short Development and Validation of a Complete GATE Model of the Siemens Inveon Trimodal Imaging Platform
title_sort development and validation of a complete gate model of the siemens inveon trimodal imaging platform
url https://doi.org/10.2310/7290.2013.00058
work_keys_str_mv AT sanghyeblee developmentandvalidationofacompletegatemodelofthesiemensinveontrimodalimagingplatform
AT jensgregor developmentandvalidationofacompletegatemodelofthesiemensinveontrimodalimagingplatform
AT dustinosborne developmentandvalidationofacompletegatemodelofthesiemensinveontrimodalimagingplatform