Life‐Threatening Tension Haemopneumothorax After Removal of a Misplaced Dialysis Catheter: A Novel Complication and Its Management
ABSTRACT Central venous catheters are frequently required for temporary vascular access in patients with inaccessible peripheral venous access and in patients requiring haemodialysis. Although generally safe, catheter insertion without ultrasound guidance can lead to severe complications. This case...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2025-04-01
|
| Series: | Respirology Case Reports |
| Subjects: | |
| Online Access: | https://doi.org/10.1002/rcr2.70178 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850141326960492544 |
|---|---|
| author | Nivy Patel Hiren Rathod Mohammed Nadeem Patel Preet Baxi Sagar Kabde |
| author_facet | Nivy Patel Hiren Rathod Mohammed Nadeem Patel Preet Baxi Sagar Kabde |
| author_sort | Nivy Patel |
| collection | DOAJ |
| description | ABSTRACT Central venous catheters are frequently required for temporary vascular access in patients with inaccessible peripheral venous access and in patients requiring haemodialysis. Although generally safe, catheter insertion without ultrasound guidance can lead to severe complications. This case report discusses a patient who presented with symptoms of a misplaced dialysis catheter and developed a life‐threatening tension haemopneumothorax during its removal, in association with prior haemothorax. We believe that tension haemopneumothorax associated with haemothorax resulting from a misplaced dialysis catheter has not been previously reported. This case also highlights the critical need for precise technique in dialysis catheter placement, preferably guided by real‐time ultrasound imaging. A multidisciplinary team approach is helpful in such complicated scenarios to optimise patient outcome. |
| format | Article |
| id | doaj-art-2811a0bb4d6b4ea992f42de3a72f8cbb |
| institution | OA Journals |
| issn | 2051-3380 |
| language | English |
| publishDate | 2025-04-01 |
| publisher | Wiley |
| record_format | Article |
| series | Respirology Case Reports |
| spelling | doaj-art-2811a0bb4d6b4ea992f42de3a72f8cbb2025-08-20T02:29:29ZengWileyRespirology Case Reports2051-33802025-04-01134n/an/a10.1002/rcr2.70178Life‐Threatening Tension Haemopneumothorax After Removal of a Misplaced Dialysis Catheter: A Novel Complication and Its ManagementNivy Patel0Hiren Rathod1Mohammed Nadeem Patel2Preet Baxi3Sagar Kabde4Department of Critical Care Unit Bankers Heart Institute Surat IndiaDepartment of Interventional Radiology Bankers Heart Institute Surat IndiaDepartment of Critical Care Unit Bankers Heart Institute Surat IndiaDepartment of Critical Care Unit Bankers Heart Institute Surat IndiaDepartment of Cardiology Bankers Heart Institute Surat IndiaABSTRACT Central venous catheters are frequently required for temporary vascular access in patients with inaccessible peripheral venous access and in patients requiring haemodialysis. Although generally safe, catheter insertion without ultrasound guidance can lead to severe complications. This case report discusses a patient who presented with symptoms of a misplaced dialysis catheter and developed a life‐threatening tension haemopneumothorax during its removal, in association with prior haemothorax. We believe that tension haemopneumothorax associated with haemothorax resulting from a misplaced dialysis catheter has not been previously reported. This case also highlights the critical need for precise technique in dialysis catheter placement, preferably guided by real‐time ultrasound imaging. A multidisciplinary team approach is helpful in such complicated scenarios to optimise patient outcome.https://doi.org/10.1002/rcr2.70178dialysis cathetersleft internal jugular veintension haemopneumothorax |
| spellingShingle | Nivy Patel Hiren Rathod Mohammed Nadeem Patel Preet Baxi Sagar Kabde Life‐Threatening Tension Haemopneumothorax After Removal of a Misplaced Dialysis Catheter: A Novel Complication and Its Management Respirology Case Reports dialysis catheters left internal jugular vein tension haemopneumothorax |
| title | Life‐Threatening Tension Haemopneumothorax After Removal of a Misplaced Dialysis Catheter: A Novel Complication and Its Management |
| title_full | Life‐Threatening Tension Haemopneumothorax After Removal of a Misplaced Dialysis Catheter: A Novel Complication and Its Management |
| title_fullStr | Life‐Threatening Tension Haemopneumothorax After Removal of a Misplaced Dialysis Catheter: A Novel Complication and Its Management |
| title_full_unstemmed | Life‐Threatening Tension Haemopneumothorax After Removal of a Misplaced Dialysis Catheter: A Novel Complication and Its Management |
| title_short | Life‐Threatening Tension Haemopneumothorax After Removal of a Misplaced Dialysis Catheter: A Novel Complication and Its Management |
| title_sort | life threatening tension haemopneumothorax after removal of a misplaced dialysis catheter a novel complication and its management |
| topic | dialysis catheters left internal jugular vein tension haemopneumothorax |
| url | https://doi.org/10.1002/rcr2.70178 |
| work_keys_str_mv | AT nivypatel lifethreateningtensionhaemopneumothoraxafterremovalofamisplaceddialysiscatheteranovelcomplicationanditsmanagement AT hirenrathod lifethreateningtensionhaemopneumothoraxafterremovalofamisplaceddialysiscatheteranovelcomplicationanditsmanagement AT mohammednadeempatel lifethreateningtensionhaemopneumothoraxafterremovalofamisplaceddialysiscatheteranovelcomplicationanditsmanagement AT preetbaxi lifethreateningtensionhaemopneumothoraxafterremovalofamisplaceddialysiscatheteranovelcomplicationanditsmanagement AT sagarkabde lifethreateningtensionhaemopneumothoraxafterremovalofamisplaceddialysiscatheteranovelcomplicationanditsmanagement |