Analysis of a 40-Story Office Building Combining a Post Tensioned Flat Slab with Separated Gravity Lateral Resisting Implementation

Compared to other countries, the adoption of post-tensioned flat slab (PTFS) in Indonesia is relatively limited due to the susceptibility of flat slab to lateral forces. Nevertheless, flat slabs in high seismic zones scan still be achieved by utilizing the separated gravity lateral resisting (SGLR)...

Full description

Saved in:
Bibliographic Details
Main Authors: Alexandra Patricia Andriani, Jessica Sjah, Indra Nurudin Fathoni, Nuraziz Handika
Format: Article
Language:English
Published: MDPI AG 2025-01-01
Series:Engineering Proceedings
Subjects:
Online Access:https://www.mdpi.com/2673-4591/84/1/26
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849432050662113280
author Alexandra Patricia Andriani
Jessica Sjah
Indra Nurudin Fathoni
Nuraziz Handika
author_facet Alexandra Patricia Andriani
Jessica Sjah
Indra Nurudin Fathoni
Nuraziz Handika
author_sort Alexandra Patricia Andriani
collection DOAJ
description Compared to other countries, the adoption of post-tensioned flat slab (PTFS) in Indonesia is relatively limited due to the susceptibility of flat slab to lateral forces. Nevertheless, flat slabs in high seismic zones scan still be achieved by utilizing the separated gravity lateral resisting (SGLR) system. This study analyzes a 40-story office building by comparing the structural response, volume, and cost of PTFS with conventional structures. The findings reveal that PTFSs exhibit greater story drift and displacement but experience reduced story shear and overturning moments with a reduction in concrete volume of up to 10% and a 6% decrease in overall costs.
format Article
id doaj-art-26f7abc63c424bc2a683178bc14a8cfe
institution Kabale University
issn 2673-4591
language English
publishDate 2025-01-01
publisher MDPI AG
record_format Article
series Engineering Proceedings
spelling doaj-art-26f7abc63c424bc2a683178bc14a8cfe2025-08-20T03:27:28ZengMDPI AGEngineering Proceedings2673-45912025-01-018412610.3390/engproc2025084026Analysis of a 40-Story Office Building Combining a Post Tensioned Flat Slab with Separated Gravity Lateral Resisting ImplementationAlexandra Patricia Andriani0Jessica Sjah1Indra Nurudin Fathoni2Nuraziz Handika3Department of Civil Engineering, Universitas Indonesia, Depok 16424, IndonesiaDepartment of Civil Engineering, Universitas Indonesia, Depok 16424, IndonesiaPT Delta Utracon Synergy, Jakarta Selatan 12740, IndonesiaDepartment of Civil Engineering, Universitas Indonesia, Depok 16424, IndonesiaCompared to other countries, the adoption of post-tensioned flat slab (PTFS) in Indonesia is relatively limited due to the susceptibility of flat slab to lateral forces. Nevertheless, flat slabs in high seismic zones scan still be achieved by utilizing the separated gravity lateral resisting (SGLR) system. This study analyzes a 40-story office building by comparing the structural response, volume, and cost of PTFS with conventional structures. The findings reveal that PTFSs exhibit greater story drift and displacement but experience reduced story shear and overturning moments with a reduction in concrete volume of up to 10% and a 6% decrease in overall costs.https://www.mdpi.com/2673-4591/84/1/26post-tensionedflat slabSGLR systemdual systemvolume analysiscost analysis
spellingShingle Alexandra Patricia Andriani
Jessica Sjah
Indra Nurudin Fathoni
Nuraziz Handika
Analysis of a 40-Story Office Building Combining a Post Tensioned Flat Slab with Separated Gravity Lateral Resisting Implementation
Engineering Proceedings
post-tensioned
flat slab
SGLR system
dual system
volume analysis
cost analysis
title Analysis of a 40-Story Office Building Combining a Post Tensioned Flat Slab with Separated Gravity Lateral Resisting Implementation
title_full Analysis of a 40-Story Office Building Combining a Post Tensioned Flat Slab with Separated Gravity Lateral Resisting Implementation
title_fullStr Analysis of a 40-Story Office Building Combining a Post Tensioned Flat Slab with Separated Gravity Lateral Resisting Implementation
title_full_unstemmed Analysis of a 40-Story Office Building Combining a Post Tensioned Flat Slab with Separated Gravity Lateral Resisting Implementation
title_short Analysis of a 40-Story Office Building Combining a Post Tensioned Flat Slab with Separated Gravity Lateral Resisting Implementation
title_sort analysis of a 40 story office building combining a post tensioned flat slab with separated gravity lateral resisting implementation
topic post-tensioned
flat slab
SGLR system
dual system
volume analysis
cost analysis
url https://www.mdpi.com/2673-4591/84/1/26
work_keys_str_mv AT alexandrapatriciaandriani analysisofa40storyofficebuildingcombiningaposttensionedflatslabwithseparatedgravitylateralresistingimplementation
AT jessicasjah analysisofa40storyofficebuildingcombiningaposttensionedflatslabwithseparatedgravitylateralresistingimplementation
AT indranurudinfathoni analysisofa40storyofficebuildingcombiningaposttensionedflatslabwithseparatedgravitylateralresistingimplementation
AT nurazizhandika analysisofa40storyofficebuildingcombiningaposttensionedflatslabwithseparatedgravitylateralresistingimplementation