Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department

Objectives Single-use commercial surface fiducial markers are used in clinical imaging for a variety of applications. The current study sought to find a new, reliably visible, easily sourced and inexpensive fiducial marker alternative for use with MRI.Design Five commonly requested MRI sequences wer...

Full description

Saved in:
Bibliographic Details
Main Authors: Maree T Izatt, Deborah Lees, Susan Mills, Caroline A Grant, J Paige Little
Format: Article
Language:English
Published: BMJ Publishing Group 2019-08-01
Series:BMJ Open
Online Access:https://bmjopen.bmj.com/content/9/8/e027020.full
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846156225111130112
author Maree T Izatt
Deborah Lees
Susan Mills
Caroline A Grant
J Paige Little
author_facet Maree T Izatt
Deborah Lees
Susan Mills
Caroline A Grant
J Paige Little
author_sort Maree T Izatt
collection DOAJ
description Objectives Single-use commercial surface fiducial markers are used in clinical imaging for a variety of applications. The current study sought to find a new, reliably visible, easily sourced and inexpensive fiducial marker alternative for use with MRI.Design Five commonly requested MRI sequences were determined (three-dimensional (3D) T1-weighted, T1 coronal, 3D T2-weighted, T2 fat suppressed, proton density), to examine the visibility of 18 items (including a commercial fiducial marker).Setting Clinical 3T MRI scanner in an Australian Tertiary Hospital and an Australian University Biomedical Engineering research group.Interventions 18 marker alternatives were scanned using five common MRI sequences. Images were reformatted to obtain both an image through the mid-height of each marker and a maximum intensity z-projection image over the volume of the marker. Variations in marker intensity were profiled across each visible marker and a visibility rating defined.Main outcome measures Outcome measures were based on quantitative assessment of a clear intensity contrast ratio between the marker and the adjacent tissue and a qualitative assessment of visibility via a 3-point scale.Results The fish oil capsule, vitamin D capsule, paint ball pellet, soy sauce sushi tube and commercial markers were typically visible to a high quality on all the imaging sequences and demonstrated a clear differential in intensity contrast against the adjacent tissue. Other common items, such as plasticine ‘play doh’ and a soft ‘Jelly baby’ sweet, were surprise candidates, demonstrating high-quality visibility and intensity contrast for the 3D T1-weighted sequence.Conclusions Depending on the basis for referral and MRI sequence chosen, four alternative fiducial markers were determined to be inexpensive, easily sourced and consistently visible. Of these, the vitamin D capsule provided an excellent balance between availability, size, cost, usability and quality of the visualised marker for all the commonly used MRI sequences analysed.
format Article
id doaj-art-25ac3ab3a3a34b7ab741565f8301296c
institution Kabale University
issn 2044-6055
language English
publishDate 2019-08-01
publisher BMJ Publishing Group
record_format Article
series BMJ Open
spelling doaj-art-25ac3ab3a3a34b7ab741565f8301296c2024-11-26T09:10:11ZengBMJ Publishing GroupBMJ Open2044-60552019-08-019810.1136/bmjopen-2018-027020Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology DepartmentMaree T Izatt0Deborah Lees1Susan Mills2Caroline A Grant3J Paige Little41 Biomechanics and Spine Research Group, Queensland University of Technology, Brisbane, Queensland, Australia1 Biomechanics and Spine Research Group, Queensland University of Technology, Brisbane, Queensland, Australia2 Mater Medical Imaging, Mater Misericordiae Brisbane Ltd, South Brisbane, Queensland, Australia1 Biomechanics and Spine Research Group, Queensland University of Technology, Brisbane, Queensland, Australia1 Biomechanics and Spine Research Group, Queensland University of Technology, Brisbane, Queensland, AustraliaObjectives Single-use commercial surface fiducial markers are used in clinical imaging for a variety of applications. The current study sought to find a new, reliably visible, easily sourced and inexpensive fiducial marker alternative for use with MRI.Design Five commonly requested MRI sequences were determined (three-dimensional (3D) T1-weighted, T1 coronal, 3D T2-weighted, T2 fat suppressed, proton density), to examine the visibility of 18 items (including a commercial fiducial marker).Setting Clinical 3T MRI scanner in an Australian Tertiary Hospital and an Australian University Biomedical Engineering research group.Interventions 18 marker alternatives were scanned using five common MRI sequences. Images were reformatted to obtain both an image through the mid-height of each marker and a maximum intensity z-projection image over the volume of the marker. Variations in marker intensity were profiled across each visible marker and a visibility rating defined.Main outcome measures Outcome measures were based on quantitative assessment of a clear intensity contrast ratio between the marker and the adjacent tissue and a qualitative assessment of visibility via a 3-point scale.Results The fish oil capsule, vitamin D capsule, paint ball pellet, soy sauce sushi tube and commercial markers were typically visible to a high quality on all the imaging sequences and demonstrated a clear differential in intensity contrast against the adjacent tissue. Other common items, such as plasticine ‘play doh’ and a soft ‘Jelly baby’ sweet, were surprise candidates, demonstrating high-quality visibility and intensity contrast for the 3D T1-weighted sequence.Conclusions Depending on the basis for referral and MRI sequence chosen, four alternative fiducial markers were determined to be inexpensive, easily sourced and consistently visible. Of these, the vitamin D capsule provided an excellent balance between availability, size, cost, usability and quality of the visualised marker for all the commonly used MRI sequences analysed.https://bmjopen.bmj.com/content/9/8/e027020.full
spellingShingle Maree T Izatt
Deborah Lees
Susan Mills
Caroline A Grant
J Paige Little
Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
BMJ Open
title Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_full Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_fullStr Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_full_unstemmed Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_short Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_sort determining a reliably visible and inexpensive surface fiducial marker for use in mri a research study in a busy australian radiology department
url https://bmjopen.bmj.com/content/9/8/e027020.full
work_keys_str_mv AT mareetizatt determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment
AT deborahlees determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment
AT susanmills determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment
AT carolineagrant determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment
AT jpaigelittle determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment