Evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening: an in vitro study

Abstract Background Intraoral scanners (IOS) are increasingly utilized in pediatric dentistry to capture digital impressions, offering advantages over traditional impression materials, particularly in young patients. However, the accuracy and precision of these devices may be influenced by factors s...

Full description

Saved in:
Bibliographic Details
Main Author: Hamit Tunç
Format: Article
Language:English
Published: BMC 2025-07-01
Series:BMC Oral Health
Subjects:
Online Access:https://doi.org/10.1186/s12903-025-06640-9
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849738314394894336
author Hamit Tunç
author_facet Hamit Tunç
author_sort Hamit Tunç
collection DOAJ
description Abstract Background Intraoral scanners (IOS) are increasingly utilized in pediatric dentistry to capture digital impressions, offering advantages over traditional impression materials, particularly in young patients. However, the accuracy and precision of these devices may be influenced by factors such as limited mouth opening, which is common in pediatric patients. This study aims to evaluate the effect of mouth opening on the accuracy of intraoral digital impressions obtained via two different IOS technologies: confocal microscopy (Trios 5) and structured light triangulation (Helios 600). Methods A typodont deciduous teeth model was scanned at three mouth opening levels (28 mm, 33 mm, 37 mm) using both IOS. Accuracy was analyzed through two-dimensional (2D) linear measurements and three-dimensional (3D) superimpositions, assessing trueness and precision. Statistical analysis was performed using Kruskal–Wallis and Mann–Whitney U tests (p < 0.05). Results At all mouth opening levels, no statistically significant differences in trueness were observed between the two scanners (p > 0.05). However, a significant difference in precision was found at the 28 mm opening, where the Helios 600 exhibited notably lower 2D precision compared to the Trios 5, both in the maxilla (p = 0.02) and mandible (p = 0.03). The 3D precision values for scans obtained with the Helios 600 were statistically significantly lower than those obtained with the Trios 5, both in the maxilla (p = 0.017) and mandible (p = 0.021). No significant differences in precision were observed at the 33 mm and 37 mm openings (p > 0.05). Conclusions This study demonstrated that both the Trios 5 and Helios 600 intraoral scanners provided clinically acceptable trueness values. However, Trios 5 exhibited significantly better precision, particularly in cases with limited mouth opening. These results suggest that Trios 5 may offer improved reliability, especially for pediatric patients with reduced mouth opening.
format Article
id doaj-art-25a3d54eb87b403cbc84d3929fb7e9e6
institution DOAJ
issn 1472-6831
language English
publishDate 2025-07-01
publisher BMC
record_format Article
series BMC Oral Health
spelling doaj-art-25a3d54eb87b403cbc84d3929fb7e9e62025-08-20T03:06:39ZengBMCBMC Oral Health1472-68312025-07-0125111510.1186/s12903-025-06640-9Evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening: an in vitro studyHamit Tunç0Faculty of Dentistry, Department of Pediatric Dentistry, Burdur Mehmet Akif Ersoy UniversityAbstract Background Intraoral scanners (IOS) are increasingly utilized in pediatric dentistry to capture digital impressions, offering advantages over traditional impression materials, particularly in young patients. However, the accuracy and precision of these devices may be influenced by factors such as limited mouth opening, which is common in pediatric patients. This study aims to evaluate the effect of mouth opening on the accuracy of intraoral digital impressions obtained via two different IOS technologies: confocal microscopy (Trios 5) and structured light triangulation (Helios 600). Methods A typodont deciduous teeth model was scanned at three mouth opening levels (28 mm, 33 mm, 37 mm) using both IOS. Accuracy was analyzed through two-dimensional (2D) linear measurements and three-dimensional (3D) superimpositions, assessing trueness and precision. Statistical analysis was performed using Kruskal–Wallis and Mann–Whitney U tests (p < 0.05). Results At all mouth opening levels, no statistically significant differences in trueness were observed between the two scanners (p > 0.05). However, a significant difference in precision was found at the 28 mm opening, where the Helios 600 exhibited notably lower 2D precision compared to the Trios 5, both in the maxilla (p = 0.02) and mandible (p = 0.03). The 3D precision values for scans obtained with the Helios 600 were statistically significantly lower than those obtained with the Trios 5, both in the maxilla (p = 0.017) and mandible (p = 0.021). No significant differences in precision were observed at the 33 mm and 37 mm openings (p > 0.05). Conclusions This study demonstrated that both the Trios 5 and Helios 600 intraoral scanners provided clinically acceptable trueness values. However, Trios 5 exhibited significantly better precision, particularly in cases with limited mouth opening. These results suggest that Trios 5 may offer improved reliability, especially for pediatric patients with reduced mouth opening.https://doi.org/10.1186/s12903-025-06640-9Intraoral scannersPediatric patientsAccuracyMouth openning
spellingShingle Hamit Tunç
Evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening: an in vitro study
BMC Oral Health
Intraoral scanners
Pediatric patients
Accuracy
Mouth openning
title Evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening: an in vitro study
title_full Evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening: an in vitro study
title_fullStr Evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening: an in vitro study
title_full_unstemmed Evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening: an in vitro study
title_short Evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening: an in vitro study
title_sort evaluation of the accuracy of digital impressions obtained with confocal microscopy and structured light triangulation systems in pediatric patients with different mouth opening an in vitro study
topic Intraoral scanners
Pediatric patients
Accuracy
Mouth openning
url https://doi.org/10.1186/s12903-025-06640-9
work_keys_str_mv AT hamittunc evaluationoftheaccuracyofdigitalimpressionsobtainedwithconfocalmicroscopyandstructuredlighttriangulationsystemsinpediatricpatientswithdifferentmouthopeninganinvitrostudy