Iraqi Drinking Water Quality Standards (IQS 417/ 2009) – Revisited

Iraq was one of the first developing countries to specify standard limits on drinking water quality. In 1967, (Law No. 25/1967) was issued. In 2001, new standard specifications of drinking water quality were issued (IQS/ 417/2001) and revised in 2009. These revisions did not significantly change th...

Full description

Saved in:
Bibliographic Details
Main Author: Hala Adnan Abbas
Format: Article
Language:English
Published: Tikrit University 2025-03-01
Series:Tikrit Journal of Engineering Sciences
Subjects:
Online Access:https://tj-es.com/ojs/index.php/tjes/article/view/1606
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849314751367086080
author Hala Adnan Abbas
author_facet Hala Adnan Abbas
author_sort Hala Adnan Abbas
collection DOAJ
description Iraq was one of the first developing countries to specify standard limits on drinking water quality. In 1967, (Law No. 25/1967) was issued. In 2001, new standard specifications of drinking water quality were issued (IQS/ 417/2001) and revised in 2009. These revisions did not significantly change the numerical limit values of major water quality parameters to reflect any major technological advancement in water quality sciences and epidemiological studies. The aim of this study is to set a numerical limit value for the drinking water temperature parameter to be promulgated and added to law IQS/ 417. Field water samples were collected from different sites in Baghdad. The water source in this study was the Tigris River from three water treatment plants and customer taps at selected districts whose water supplies were fed from these three water treatment plants. These samples’ temperatures were measured by a good-grade mercury-filled Celsius thermometer on site. A literature survey on drinking water temperatures was conducted to collate as much relevant information as possible from countries in the Middle-Eastern region and Europe to compare them with the present results. It was found that the drinking water supply temperature in Baghdad was impacted by the temperature of the water supply source and the pipe distribution network. High averages of drinking water temperature prevailed during the summer season. It is recommended that a temperature limit value for potable water at customer taps should be below 25 ºC, based on health aspects. This recommendation should be promulgated and included in law (IQS/ 417), depending on the public health requirements.
format Article
id doaj-art-25967716b6a949e5a6b0434ac9ec2fd7
institution Kabale University
issn 1813-162X
2312-7589
language English
publishDate 2025-03-01
publisher Tikrit University
record_format Article
series Tikrit Journal of Engineering Sciences
spelling doaj-art-25967716b6a949e5a6b0434ac9ec2fd72025-08-20T03:52:20ZengTikrit UniversityTikrit Journal of Engineering Sciences1813-162X2312-75892025-03-0132110.25130/tjes.32.1.23Iraqi Drinking Water Quality Standards (IQS 417/ 2009) – RevisitedHala Adnan Abbas0https://orcid.org/0000-0003-4160-0988Civil Engineering Department, University of Technology, Baghdad, Iraq. Iraq was one of the first developing countries to specify standard limits on drinking water quality. In 1967, (Law No. 25/1967) was issued. In 2001, new standard specifications of drinking water quality were issued (IQS/ 417/2001) and revised in 2009. These revisions did not significantly change the numerical limit values of major water quality parameters to reflect any major technological advancement in water quality sciences and epidemiological studies. The aim of this study is to set a numerical limit value for the drinking water temperature parameter to be promulgated and added to law IQS/ 417. Field water samples were collected from different sites in Baghdad. The water source in this study was the Tigris River from three water treatment plants and customer taps at selected districts whose water supplies were fed from these three water treatment plants. These samples’ temperatures were measured by a good-grade mercury-filled Celsius thermometer on site. A literature survey on drinking water temperatures was conducted to collate as much relevant information as possible from countries in the Middle-Eastern region and Europe to compare them with the present results. It was found that the drinking water supply temperature in Baghdad was impacted by the temperature of the water supply source and the pipe distribution network. High averages of drinking water temperature prevailed during the summer season. It is recommended that a temperature limit value for potable water at customer taps should be below 25 ºC, based on health aspects. This recommendation should be promulgated and included in law (IQS/ 417), depending on the public health requirements. https://tj-es.com/ojs/index.php/tjes/article/view/1606Drinking water network specificationFrost zoneHeat zoneIraq drinking water quality standardsPipe depthTap water temperature
spellingShingle Hala Adnan Abbas
Iraqi Drinking Water Quality Standards (IQS 417/ 2009) – Revisited
Tikrit Journal of Engineering Sciences
Drinking water network specification
Frost zone
Heat zone
Iraq drinking water quality standards
Pipe depth
Tap water temperature
title Iraqi Drinking Water Quality Standards (IQS 417/ 2009) – Revisited
title_full Iraqi Drinking Water Quality Standards (IQS 417/ 2009) – Revisited
title_fullStr Iraqi Drinking Water Quality Standards (IQS 417/ 2009) – Revisited
title_full_unstemmed Iraqi Drinking Water Quality Standards (IQS 417/ 2009) – Revisited
title_short Iraqi Drinking Water Quality Standards (IQS 417/ 2009) – Revisited
title_sort iraqi drinking water quality standards iqs 417 2009 revisited
topic Drinking water network specification
Frost zone
Heat zone
Iraq drinking water quality standards
Pipe depth
Tap water temperature
url https://tj-es.com/ojs/index.php/tjes/article/view/1606
work_keys_str_mv AT halaadnanabbas iraqidrinkingwaterqualitystandardsiqs4172009revisited