Numerical Simulations on the Extinguishing Effect of Water Mist System with Different Parameters of Longitudinal Ventilation in Curve Tunnel Fire

Once a fire occurs in a long curve tunnel, the mixing of hot smoke flow and cold air leads to turbulence due to the curvature’s impact. This phenomenon results in a greater thermal pressure difference at the fire source and a substantially greater temperature field than in the straight tunnel. The l...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhizhong Liu, Chen Chen, Mu Liu, Song Wang, Yuzhu Liu
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2021/7373685
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832561551684403200
author Zhizhong Liu
Chen Chen
Mu Liu
Song Wang
Yuzhu Liu
author_facet Zhizhong Liu
Chen Chen
Mu Liu
Song Wang
Yuzhu Liu
author_sort Zhizhong Liu
collection DOAJ
description Once a fire occurs in a long curve tunnel, the mixing of hot smoke flow and cold air leads to turbulence due to the curvature’s impact. This phenomenon results in a greater thermal pressure difference at the fire source and a substantially greater temperature field than in the straight tunnel. The longitudinal air flowing along the wall loses a lot of velocity in the curve tunnel due to the massive wall friction. Under the same fire extinguishing conditions, the curve tunnel and straight tunnel have different requirements for longitudinal ventilation. Factors such as tunnel curvature, longitudinal ventilation operation time, and ventilation velocity were all evaluated in order to investigate the influence of longitudinal ventilation parameters on the fire extinguishing effect of water mist in the curve tunnel. The fire extinguishing effect of water mist coupling with longitudinal ventilation in the curve tunnel is studied by numerical simulation, and the recommended values of ventilation operation time and ventilation velocity in the curve tunnel with the participation of the water mist system are given. The results show that (1) the fire extinguishing effect of water mist decreases with the increase of curvature under longitudinal ventilation and (2) fire prevention effect is best when water mist and longitudinal ventilation are used in the curved tunnel, and the ventilation velocity should be greater than 2 m/s.
format Article
id doaj-art-25000786aa11491384f1038e557d498f
institution Kabale University
issn 1687-8086
1687-8094
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-25000786aa11491384f1038e557d498f2025-02-03T01:24:47ZengWileyAdvances in Civil Engineering1687-80861687-80942021-01-01202110.1155/2021/73736857373685Numerical Simulations on the Extinguishing Effect of Water Mist System with Different Parameters of Longitudinal Ventilation in Curve Tunnel FireZhizhong Liu0Chen Chen1Mu Liu2Song Wang3Yuzhu Liu4Hebei Provincial Expressway Yanqing-Chongli Construction Office, Zhangjiakou 075000, ChinaHebei Provincial Expressway Yanqing-Chongli Construction Office, Zhangjiakou 075000, ChinaHebei Provincial Expressway Yanqing-Chongli Construction Office, Zhangjiakou 075000, ChinaKey Laboratory of Transportation Tunnel Engineering, Ministry of Education, Southwest Jiaotong University, Chengdu 610031, ChinaKey Laboratory of Transportation Tunnel Engineering, Ministry of Education, Southwest Jiaotong University, Chengdu 610031, ChinaOnce a fire occurs in a long curve tunnel, the mixing of hot smoke flow and cold air leads to turbulence due to the curvature’s impact. This phenomenon results in a greater thermal pressure difference at the fire source and a substantially greater temperature field than in the straight tunnel. The longitudinal air flowing along the wall loses a lot of velocity in the curve tunnel due to the massive wall friction. Under the same fire extinguishing conditions, the curve tunnel and straight tunnel have different requirements for longitudinal ventilation. Factors such as tunnel curvature, longitudinal ventilation operation time, and ventilation velocity were all evaluated in order to investigate the influence of longitudinal ventilation parameters on the fire extinguishing effect of water mist in the curve tunnel. The fire extinguishing effect of water mist coupling with longitudinal ventilation in the curve tunnel is studied by numerical simulation, and the recommended values of ventilation operation time and ventilation velocity in the curve tunnel with the participation of the water mist system are given. The results show that (1) the fire extinguishing effect of water mist decreases with the increase of curvature under longitudinal ventilation and (2) fire prevention effect is best when water mist and longitudinal ventilation are used in the curved tunnel, and the ventilation velocity should be greater than 2 m/s.http://dx.doi.org/10.1155/2021/7373685
spellingShingle Zhizhong Liu
Chen Chen
Mu Liu
Song Wang
Yuzhu Liu
Numerical Simulations on the Extinguishing Effect of Water Mist System with Different Parameters of Longitudinal Ventilation in Curve Tunnel Fire
Advances in Civil Engineering
title Numerical Simulations on the Extinguishing Effect of Water Mist System with Different Parameters of Longitudinal Ventilation in Curve Tunnel Fire
title_full Numerical Simulations on the Extinguishing Effect of Water Mist System with Different Parameters of Longitudinal Ventilation in Curve Tunnel Fire
title_fullStr Numerical Simulations on the Extinguishing Effect of Water Mist System with Different Parameters of Longitudinal Ventilation in Curve Tunnel Fire
title_full_unstemmed Numerical Simulations on the Extinguishing Effect of Water Mist System with Different Parameters of Longitudinal Ventilation in Curve Tunnel Fire
title_short Numerical Simulations on the Extinguishing Effect of Water Mist System with Different Parameters of Longitudinal Ventilation in Curve Tunnel Fire
title_sort numerical simulations on the extinguishing effect of water mist system with different parameters of longitudinal ventilation in curve tunnel fire
url http://dx.doi.org/10.1155/2021/7373685
work_keys_str_mv AT zhizhongliu numericalsimulationsontheextinguishingeffectofwatermistsystemwithdifferentparametersoflongitudinalventilationincurvetunnelfire
AT chenchen numericalsimulationsontheextinguishingeffectofwatermistsystemwithdifferentparametersoflongitudinalventilationincurvetunnelfire
AT muliu numericalsimulationsontheextinguishingeffectofwatermistsystemwithdifferentparametersoflongitudinalventilationincurvetunnelfire
AT songwang numericalsimulationsontheextinguishingeffectofwatermistsystemwithdifferentparametersoflongitudinalventilationincurvetunnelfire
AT yuzhuliu numericalsimulationsontheextinguishingeffectofwatermistsystemwithdifferentparametersoflongitudinalventilationincurvetunnelfire