Research on Annual Performance Factor of Water-water Heat Pump System
The annual performance factor(APF) optimization of water-water heat pump was presented.Based on the building load in a whole year,the APF of a heat pump was defined and used as the optimization function,with the area ratio of heat exchanger as the optimization variable.The optimization mathematical...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2006-01-01
|
| Series: | Zhileng xuebao |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.006 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849705392977739776 |
|---|---|
| author | 杨昭 赵海波 胡云峰 吴坤 |
| author_facet | 杨昭 赵海波 胡云峰 吴坤 |
| author_sort | 杨昭 |
| collection | DOAJ |
| description | The annual performance factor(APF) optimization of water-water heat pump was presented.Based on the building load in a whole year,the APF of a heat pump was defined and used as the optimization function,with the area ratio of heat exchanger as the optimization variable.The optimization mathematical models for the on-off control scheme were set up to calculate the APF to study the optimal design and matching between different components.Comparison with different optimization designs with HSPF,SEER,and EER,the APF optimization is nearer to the reality. |
| format | Article |
| id | doaj-art-22cb7fac9953437ea921b817cb5f387c |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2006-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-22cb7fac9953437ea921b817cb5f387c2025-08-20T03:16:29ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392006-01-0166524312Research on Annual Performance Factor of Water-water Heat Pump System杨昭赵海波胡云峰吴坤The annual performance factor(APF) optimization of water-water heat pump was presented.Based on the building load in a whole year,the APF of a heat pump was defined and used as the optimization function,with the area ratio of heat exchanger as the optimization variable.The optimization mathematical models for the on-off control scheme were set up to calculate the APF to study the optimal design and matching between different components.Comparison with different optimization designs with HSPF,SEER,and EER,the APF optimization is nearer to the reality.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.006 |
| spellingShingle | 杨昭 赵海波 胡云峰 吴坤 Research on Annual Performance Factor of Water-water Heat Pump System Zhileng xuebao |
| title | Research on Annual Performance Factor of Water-water Heat Pump System |
| title_full | Research on Annual Performance Factor of Water-water Heat Pump System |
| title_fullStr | Research on Annual Performance Factor of Water-water Heat Pump System |
| title_full_unstemmed | Research on Annual Performance Factor of Water-water Heat Pump System |
| title_short | Research on Annual Performance Factor of Water-water Heat Pump System |
| title_sort | research on annual performance factor of water water heat pump system |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.006 |
| work_keys_str_mv | AT yángzhāo researchonannualperformancefactorofwaterwaterheatpumpsystem AT zhàohǎibō researchonannualperformancefactorofwaterwaterheatpumpsystem AT húyúnfēng researchonannualperformancefactorofwaterwaterheatpumpsystem AT wúkūn researchonannualperformancefactorofwaterwaterheatpumpsystem |