Research on Annual Performance Factor of Water-water Heat Pump System

The annual performance factor(APF) optimization of water-water heat pump was presented.Based on the building load in a whole year,the APF of a heat pump was defined and used as the optimization function,with the area ratio of heat exchanger as the optimization variable.The optimization mathematical...

Full description

Saved in:
Bibliographic Details
Main Authors: 杨昭, 赵海波, 胡云峰, 吴坤
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2006-01-01
Series:Zhileng xuebao
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.006
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849705392977739776
author 杨昭
赵海波
胡云峰
吴坤
author_facet 杨昭
赵海波
胡云峰
吴坤
author_sort 杨昭
collection DOAJ
description The annual performance factor(APF) optimization of water-water heat pump was presented.Based on the building load in a whole year,the APF of a heat pump was defined and used as the optimization function,with the area ratio of heat exchanger as the optimization variable.The optimization mathematical models for the on-off control scheme were set up to calculate the APF to study the optimal design and matching between different components.Comparison with different optimization designs with HSPF,SEER,and EER,the APF optimization is nearer to the reality.
format Article
id doaj-art-22cb7fac9953437ea921b817cb5f387c
institution DOAJ
issn 0253-4339
language zho
publishDate 2006-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-22cb7fac9953437ea921b817cb5f387c2025-08-20T03:16:29ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392006-01-0166524312Research on Annual Performance Factor of Water-water Heat Pump System杨昭赵海波胡云峰吴坤The annual performance factor(APF) optimization of water-water heat pump was presented.Based on the building load in a whole year,the APF of a heat pump was defined and used as the optimization function,with the area ratio of heat exchanger as the optimization variable.The optimization mathematical models for the on-off control scheme were set up to calculate the APF to study the optimal design and matching between different components.Comparison with different optimization designs with HSPF,SEER,and EER,the APF optimization is nearer to the reality.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.006
spellingShingle 杨昭
赵海波
胡云峰
吴坤
Research on Annual Performance Factor of Water-water Heat Pump System
Zhileng xuebao
title Research on Annual Performance Factor of Water-water Heat Pump System
title_full Research on Annual Performance Factor of Water-water Heat Pump System
title_fullStr Research on Annual Performance Factor of Water-water Heat Pump System
title_full_unstemmed Research on Annual Performance Factor of Water-water Heat Pump System
title_short Research on Annual Performance Factor of Water-water Heat Pump System
title_sort research on annual performance factor of water water heat pump system
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.006
work_keys_str_mv AT yángzhāo researchonannualperformancefactorofwaterwaterheatpumpsystem
AT zhàohǎibō researchonannualperformancefactorofwaterwaterheatpumpsystem
AT húyúnfēng researchonannualperformancefactorofwaterwaterheatpumpsystem
AT wúkūn researchonannualperformancefactorofwaterwaterheatpumpsystem