Impedance characteristics of aluminum with sol-gel ceria protective coating during the exposure to chloride corrosion agent

Electrochemical impedance characteristics of bare Al and Al with CeO2 coating prepared sol-gel procedure from the ceria sol are investigated. The corrosion behavior is monitored during the exposure to 3 wt. % NaCl aqueous solution. Experimental data are fitted to various equivalent electrical circui...

Full description

Saved in:
Bibliographic Details
Main Authors: Vladimir V. Panić, Stanković Vesna B. Mišković
Format: Article
Language:English
Published: Engineering Society for Corrosion, Belgrade 2016-06-01
Series:Zaštita Materijala
Subjects:
Online Access:https://www.zastita-materijala.org/index.php/home/article/view/710
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Electrochemical impedance characteristics of bare Al and Al with CeO2 coating prepared sol-gel procedure from the ceria sol are investigated. The corrosion behavior is monitored during the exposure to 3 wt. % NaCl aqueous solution. Experimental data are fitted to various equivalent electrical circuits with special attention to inductive features. Equivalent electrical circuits involving inductivity represent impedance response equally well as the ones without inductivity, although the parameter values gained from the former correspond better to the proposed model of physicochemical changes during corrosion of investigated samples.
ISSN:0351-9465
2466-2585