Case report: Transmuscular migration of a solid encircling silicone band through all four rectus muscles
PurposeWe present a case of transmuscular migration of a solid encircling silicone band through all four rectus muscles.ObservationsA 33-year-old male with high myopia presented with a progressively worsening subclinical peripheral rhegmatogenous retinal detachment in his left eye. An encircling sil...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Frontiers Media S.A.
2025-01-01
|
Series: | Frontiers in Medicine |
Subjects: | |
Online Access: | https://www.frontiersin.org/articles/10.3389/fmed.2024.1511566/full |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841556846153826304 |
---|---|
author | Ruiping Gu Ruiping Gu Ruiping Gu Kaicheng Wu Kaicheng Wu Kaicheng Wu Chunhui Jiang Chunhui Jiang Chunhui Jiang |
author_facet | Ruiping Gu Ruiping Gu Ruiping Gu Kaicheng Wu Kaicheng Wu Kaicheng Wu Chunhui Jiang Chunhui Jiang Chunhui Jiang |
author_sort | Ruiping Gu |
collection | DOAJ |
description | PurposeWe present a case of transmuscular migration of a solid encircling silicone band through all four rectus muscles.ObservationsA 33-year-old male with high myopia presented with a progressively worsening subclinical peripheral rhegmatogenous retinal detachment in his left eye. An encircling silicone band (#240) was placed anterior to the equator, and 5-0 polyester sutures (Ethicon, Inc.) were used to secure the band at all four quadrants. Six months later, the encircling band and suture knots were visible under the bulb conjunctiva, close to the limbus in all four quadrants. One and a half years after the retinal detachment surgery, the encircling band was removed because of a mild foreign body sensation. During that surgery, it was noted that the encircling band was located anterior to the insertion of all four rectus muscles. Throughout the entire follow-up period, the position and movement of the left eye remained normal.Conclusion and importanceA deep and long bite of the sclera should be used to secure the silicone band, especially in cases of high myopia and when the band is placed anterior to the equator. Even if the encircling silicone band cheese wire through the four rectus muscles, ocular motility may still remain normal. |
format | Article |
id | doaj-art-20ae8ecde5474625a15787778a5645ee |
institution | Kabale University |
issn | 2296-858X |
language | English |
publishDate | 2025-01-01 |
publisher | Frontiers Media S.A. |
record_format | Article |
series | Frontiers in Medicine |
spelling | doaj-art-20ae8ecde5474625a15787778a5645ee2025-01-07T05:23:56ZengFrontiers Media S.A.Frontiers in Medicine2296-858X2025-01-011110.3389/fmed.2024.15115661511566Case report: Transmuscular migration of a solid encircling silicone band through all four rectus musclesRuiping Gu0Ruiping Gu1Ruiping Gu2Kaicheng Wu3Kaicheng Wu4Kaicheng Wu5Chunhui Jiang6Chunhui Jiang7Chunhui Jiang8Department of Ophthalmology and Vision Science, Eye and ENT Hospital of Fudan University, Shanghai, ChinaShanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, ChinaNHC Key Laboratory of Myopia (Fudan University), Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, ChinaDepartment of Ophthalmology and Vision Science, Eye and ENT Hospital of Fudan University, Shanghai, ChinaShanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, ChinaNHC Key Laboratory of Myopia (Fudan University), Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, ChinaDepartment of Ophthalmology and Vision Science, Eye and ENT Hospital of Fudan University, Shanghai, ChinaShanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, ChinaNHC Key Laboratory of Myopia (Fudan University), Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, ChinaPurposeWe present a case of transmuscular migration of a solid encircling silicone band through all four rectus muscles.ObservationsA 33-year-old male with high myopia presented with a progressively worsening subclinical peripheral rhegmatogenous retinal detachment in his left eye. An encircling silicone band (#240) was placed anterior to the equator, and 5-0 polyester sutures (Ethicon, Inc.) were used to secure the band at all four quadrants. Six months later, the encircling band and suture knots were visible under the bulb conjunctiva, close to the limbus in all four quadrants. One and a half years after the retinal detachment surgery, the encircling band was removed because of a mild foreign body sensation. During that surgery, it was noted that the encircling band was located anterior to the insertion of all four rectus muscles. Throughout the entire follow-up period, the position and movement of the left eye remained normal.Conclusion and importanceA deep and long bite of the sclera should be used to secure the silicone band, especially in cases of high myopia and when the band is placed anterior to the equator. Even if the encircling silicone band cheese wire through the four rectus muscles, ocular motility may still remain normal.https://www.frontiersin.org/articles/10.3389/fmed.2024.1511566/fullscleral buckling surgerytransmuscular migrationrhegmatogenous retinal detachmentcheese wire forwardencircling band |
spellingShingle | Ruiping Gu Ruiping Gu Ruiping Gu Kaicheng Wu Kaicheng Wu Kaicheng Wu Chunhui Jiang Chunhui Jiang Chunhui Jiang Case report: Transmuscular migration of a solid encircling silicone band through all four rectus muscles Frontiers in Medicine scleral buckling surgery transmuscular migration rhegmatogenous retinal detachment cheese wire forward encircling band |
title | Case report: Transmuscular migration of a solid encircling silicone band through all four rectus muscles |
title_full | Case report: Transmuscular migration of a solid encircling silicone band through all four rectus muscles |
title_fullStr | Case report: Transmuscular migration of a solid encircling silicone band through all four rectus muscles |
title_full_unstemmed | Case report: Transmuscular migration of a solid encircling silicone band through all four rectus muscles |
title_short | Case report: Transmuscular migration of a solid encircling silicone band through all four rectus muscles |
title_sort | case report transmuscular migration of a solid encircling silicone band through all four rectus muscles |
topic | scleral buckling surgery transmuscular migration rhegmatogenous retinal detachment cheese wire forward encircling band |
url | https://www.frontiersin.org/articles/10.3389/fmed.2024.1511566/full |
work_keys_str_mv | AT ruipinggu casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles AT ruipinggu casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles AT ruipinggu casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles AT kaichengwu casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles AT kaichengwu casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles AT kaichengwu casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles AT chunhuijiang casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles AT chunhuijiang casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles AT chunhuijiang casereporttransmuscularmigrationofasolidencirclingsiliconebandthroughallfourrectusmuscles |