The effect of argon plasma coagulation on surgical suture material
Introduction. In modern surgery, there are many types of different energy used to achieve hemostasis; one of them is the energy of argon plasma coagulation. However, the impact of energy affects not only the bleeding site; it also affects the stitches lying nearby the source of bleeding. The instruc...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | Russian |
| Published: |
Academician I.P. Pavlov First St. Petersburg State Medical University
2024-04-01
|
| Series: | Учёные записки Санкт-Петербургского государственного медицинского университета им. Акад. И.П. Павлова |
| Subjects: | |
| Online Access: | https://www.sci-notes.ru/jour/article/view/991 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849241311068028928 |
|---|---|
| author | V. F. Bezhenar О. А. Ivanov Р. М. Palastin Е. К. Deriy G. Yu. Yukina Е. G. Sukhorukova |
| author_facet | V. F. Bezhenar О. А. Ivanov Р. М. Palastin Е. К. Deriy G. Yu. Yukina Е. G. Sukhorukova |
| author_sort | V. F. Bezhenar |
| collection | DOAJ |
| description | Introduction. In modern surgery, there are many types of different energy used to achieve hemostasis; one of them is the energy of argon plasma coagulation. However, the impact of energy affects not only the bleeding site; it also affects the stitches lying nearby the source of bleeding. The instructions for the use of a suture material or a coagulation tool do not describe the changes that may occur when they interact. A review of the literature found a small number of publications devoted to changes in the physical properties of suture material when exposed to it. This information is not sufficient to predict the effects of argon plasma coagulation energy on the suture material and, as a result, on wound healing or the quality of the postoperative scar.The objective was to determine changes in the biodestructive properties of synthetic absorbable suture materials with argon plasma coagulation in an in vivo experiment.Methods and materials. In the experimental study, the results of biodegradation of monofilament and polyfilament sutures after exposure to argon plasma coagulation energy were analyzed in comparison with control samples in the body of laboratory mice.Results. It can be unequivocally stated that the effect of argon plasma coagulation energy has an effect on the rate of biodegradation of both monofilament and polyfilament synthetic filaments implanted in muscle tissue.Conclusions. Suture material exposed to argon plasma coagulation may not meet the terms of partial or full biodegradation stated by the manufacturer, which may affect the quality of scar formation. |
| format | Article |
| id | doaj-art-1fd40f1fe42e403bb90cbb5dd0d53b87 |
| institution | Kabale University |
| issn | 1607-4181 2541-8807 |
| language | Russian |
| publishDate | 2024-04-01 |
| publisher | Academician I.P. Pavlov First St. Petersburg State Medical University |
| record_format | Article |
| series | Учёные записки Санкт-Петербургского государственного медицинского университета им. Акад. И.П. Павлова |
| spelling | doaj-art-1fd40f1fe42e403bb90cbb5dd0d53b872025-08-20T04:00:13ZrusAcademician I.P. Pavlov First St. Petersburg State Medical UniversityУчёные записки Санкт-Петербургского государственного медицинского университета им. Акад. И.П. Павлова1607-41812541-88072024-04-01303768310.24884/1607-4181-2023-30-3-76-83645The effect of argon plasma coagulation on surgical suture materialV. F. Bezhenar0О. А. Ivanov1Р. М. Palastin2Е. К. Deriy3G. Yu. Yukina4Е. G. Sukhorukova5Pavlov UniversityPavlov UniversityPavlov UniversityLLC «Mediaesthetic»Pavlov UniversityPavlov UniversityIntroduction. In modern surgery, there are many types of different energy used to achieve hemostasis; one of them is the energy of argon plasma coagulation. However, the impact of energy affects not only the bleeding site; it also affects the stitches lying nearby the source of bleeding. The instructions for the use of a suture material or a coagulation tool do not describe the changes that may occur when they interact. A review of the literature found a small number of publications devoted to changes in the physical properties of suture material when exposed to it. This information is not sufficient to predict the effects of argon plasma coagulation energy on the suture material and, as a result, on wound healing or the quality of the postoperative scar.The objective was to determine changes in the biodestructive properties of synthetic absorbable suture materials with argon plasma coagulation in an in vivo experiment.Methods and materials. In the experimental study, the results of biodegradation of monofilament and polyfilament sutures after exposure to argon plasma coagulation energy were analyzed in comparison with control samples in the body of laboratory mice.Results. It can be unequivocally stated that the effect of argon plasma coagulation energy has an effect on the rate of biodegradation of both monofilament and polyfilament synthetic filaments implanted in muscle tissue.Conclusions. Suture material exposed to argon plasma coagulation may not meet the terms of partial or full biodegradation stated by the manufacturer, which may affect the quality of scar formation.https://www.sci-notes.ru/jour/article/view/991strengthargon plasma coagulationsuture materialvicrylmonocryl |
| spellingShingle | V. F. Bezhenar О. А. Ivanov Р. М. Palastin Е. К. Deriy G. Yu. Yukina Е. G. Sukhorukova The effect of argon plasma coagulation on surgical suture material Учёные записки Санкт-Петербургского государственного медицинского университета им. Акад. И.П. Павлова strength argon plasma coagulation suture material vicryl monocryl |
| title | The effect of argon plasma coagulation on surgical suture material |
| title_full | The effect of argon plasma coagulation on surgical suture material |
| title_fullStr | The effect of argon plasma coagulation on surgical suture material |
| title_full_unstemmed | The effect of argon plasma coagulation on surgical suture material |
| title_short | The effect of argon plasma coagulation on surgical suture material |
| title_sort | effect of argon plasma coagulation on surgical suture material |
| topic | strength argon plasma coagulation suture material vicryl monocryl |
| url | https://www.sci-notes.ru/jour/article/view/991 |
| work_keys_str_mv | AT vfbezhenar theeffectofargonplasmacoagulationonsurgicalsuturematerial AT oaivanov theeffectofargonplasmacoagulationonsurgicalsuturematerial AT rmpalastin theeffectofargonplasmacoagulationonsurgicalsuturematerial AT ekderiy theeffectofargonplasmacoagulationonsurgicalsuturematerial AT gyuyukina theeffectofargonplasmacoagulationonsurgicalsuturematerial AT egsukhorukova theeffectofargonplasmacoagulationonsurgicalsuturematerial AT vfbezhenar effectofargonplasmacoagulationonsurgicalsuturematerial AT oaivanov effectofargonplasmacoagulationonsurgicalsuturematerial AT rmpalastin effectofargonplasmacoagulationonsurgicalsuturematerial AT ekderiy effectofargonplasmacoagulationonsurgicalsuturematerial AT gyuyukina effectofargonplasmacoagulationonsurgicalsuturematerial AT egsukhorukova effectofargonplasmacoagulationonsurgicalsuturematerial |