Practice of Electromagnetic Contactor Coil Working Status
Taking CX1015/08 LB electromagnetic contactor utilized in CRH3 EMUs as study object, a new method for judging contactoroperating mechanism failure by checking and comparing the coil current curves was proposed, which could quantify the failure status byanalyzing coil current waveform. Probability of...