Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT

Coronary stent fracture is a known complication of coronary arterial stent placements. Multiple long-term risks are also associated with drug eluting stents. 64-slice multidetector CT (MDCT) coronary angiography has been shown to detect poststent complications such as instent stenosis, thrombosis, s...

Full description

Saved in:
Bibliographic Details
Main Authors: Alpa Bharati, Suleman Merchant, Tilak Suvarna, Neha Parashar
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Case Reports in Cardiology
Online Access:http://dx.doi.org/10.1155/2012/214760
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832568413906534400
author Alpa Bharati
Suleman Merchant
Tilak Suvarna
Neha Parashar
author_facet Alpa Bharati
Suleman Merchant
Tilak Suvarna
Neha Parashar
author_sort Alpa Bharati
collection DOAJ
description Coronary stent fracture is a known complication of coronary arterial stent placements. Multiple long-term risks are also associated with drug eluting stents. 64-slice multidetector CT (MDCT) coronary angiography has been shown to detect poststent complications such as instent stenosis, thrombosis, stent migration and stent fractures. We report a case of stent fracture in a patient who underwent RCA stenting with associated RCA perforation and almost complete thrombosis of the RCA and peristent fibrinoid collection. This is a rare case of stent fracture with perforation of the RCA. The paper highlights the role of 64-row multidetector computed tomography (MDCT) in evaluation of such poststent placement complications.
format Article
id doaj-art-1cddcc275320429a909385cf03500f5b
institution Kabale University
issn 2090-6404
2090-6412
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series Case Reports in Cardiology
spelling doaj-art-1cddcc275320429a909385cf03500f5b2025-02-03T00:59:09ZengWileyCase Reports in Cardiology2090-64042090-64122012-01-01201210.1155/2012/214760214760Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CTAlpa Bharati0Suleman Merchant1Tilak Suvarna2Neha Parashar3Derpartment of Radiology, LTM General Hospital, Mumbai 400022, IndiaDerpartment of Radiology, LTM General Hospital, Mumbai 400022, IndiaDerpartment of Radiology, Asian Heart Institute, Mumbai 400051, IndiaDerpartment of Radiology, Asian Heart Institute, Mumbai 400051, IndiaCoronary stent fracture is a known complication of coronary arterial stent placements. Multiple long-term risks are also associated with drug eluting stents. 64-slice multidetector CT (MDCT) coronary angiography has been shown to detect poststent complications such as instent stenosis, thrombosis, stent migration and stent fractures. We report a case of stent fracture in a patient who underwent RCA stenting with associated RCA perforation and almost complete thrombosis of the RCA and peristent fibrinoid collection. This is a rare case of stent fracture with perforation of the RCA. The paper highlights the role of 64-row multidetector computed tomography (MDCT) in evaluation of such poststent placement complications.http://dx.doi.org/10.1155/2012/214760
spellingShingle Alpa Bharati
Suleman Merchant
Tilak Suvarna
Neha Parashar
Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT
Case Reports in Cardiology
title Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT
title_full Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT
title_fullStr Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT
title_full_unstemmed Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT
title_short Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT
title_sort detection of postcoronary stent complication utility of 64 slice multidetector ct
url http://dx.doi.org/10.1155/2012/214760
work_keys_str_mv AT alpabharati detectionofpostcoronarystentcomplicationutilityof64slicemultidetectorct
AT sulemanmerchant detectionofpostcoronarystentcomplicationutilityof64slicemultidetectorct
AT tilaksuvarna detectionofpostcoronarystentcomplicationutilityof64slicemultidetectorct
AT nehaparashar detectionofpostcoronarystentcomplicationutilityof64slicemultidetectorct