Experimental Investigation under Summer Conditions on Novel Integrated Dehumidification Heat Pump Air-conditioning Cycle
A normal heat pump air conditioner needs condensation dehumidification, leading to low energy efficiency. To improve the energy efficiency, a novel integrated dehumidification heat pump air-condition cycle, based on a desiccant-coated heat exchanger, is presented in this paper. Through the establish...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2018-01-01
|
| Series: | Zhileng xuebao |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2018.05.059 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849705390698135552 |
|---|---|
| author | Yuan Ye Ge Tianshu |
| author_facet | Yuan Ye Ge Tianshu |
| author_sort | Yuan Ye |
| collection | DOAJ |
| description | A normal heat pump air conditioner needs condensation dehumidification, leading to low energy efficiency. To improve the energy efficiency, a novel integrated dehumidification heat pump air-condition cycle, based on a desiccant-coated heat exchanger, is presented in this paper. Through the establishment of experiment table, the performance under summer condition of the novel cycle is tested and the influence of key operational parameters are analyzed. The results show that the novel integrated dehumidification heat pump air-condition cycle has good performance: the dehumidification quantity can reach 7.9 g/kg, and the coefficient of performance(COP)of the system can reach 5.2. The change in the temperature of fresh air and return air has influence on the temperature of supply air and COP. The change in humidity of the fresh air and return air has also influence on the temperature and humidity of the supply air, the dehumidification quantity, and COP. |
| format | Article |
| id | doaj-art-1ca4ddde12174dc08087cd6b5629948d |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2018-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-1ca4ddde12174dc08087cd6b5629948d2025-08-20T03:16:29ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392018-01-013966511565Experimental Investigation under Summer Conditions on Novel Integrated Dehumidification Heat Pump Air-conditioning CycleYuan YeGe TianshuA normal heat pump air conditioner needs condensation dehumidification, leading to low energy efficiency. To improve the energy efficiency, a novel integrated dehumidification heat pump air-condition cycle, based on a desiccant-coated heat exchanger, is presented in this paper. Through the establishment of experiment table, the performance under summer condition of the novel cycle is tested and the influence of key operational parameters are analyzed. The results show that the novel integrated dehumidification heat pump air-condition cycle has good performance: the dehumidification quantity can reach 7.9 g/kg, and the coefficient of performance(COP)of the system can reach 5.2. The change in the temperature of fresh air and return air has influence on the temperature of supply air and COP. The change in humidity of the fresh air and return air has also influence on the temperature and humidity of the supply air, the dehumidification quantity, and COP.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2018.05.059 |
| spellingShingle | Yuan Ye Ge Tianshu Experimental Investigation under Summer Conditions on Novel Integrated Dehumidification Heat Pump Air-conditioning Cycle Zhileng xuebao |
| title | Experimental Investigation under Summer Conditions on Novel Integrated Dehumidification Heat Pump Air-conditioning Cycle |
| title_full | Experimental Investigation under Summer Conditions on Novel Integrated Dehumidification Heat Pump Air-conditioning Cycle |
| title_fullStr | Experimental Investigation under Summer Conditions on Novel Integrated Dehumidification Heat Pump Air-conditioning Cycle |
| title_full_unstemmed | Experimental Investigation under Summer Conditions on Novel Integrated Dehumidification Heat Pump Air-conditioning Cycle |
| title_short | Experimental Investigation under Summer Conditions on Novel Integrated Dehumidification Heat Pump Air-conditioning Cycle |
| title_sort | experimental investigation under summer conditions on novel integrated dehumidification heat pump air conditioning cycle |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2018.05.059 |
| work_keys_str_mv | AT yuanye experimentalinvestigationundersummerconditionsonnovelintegrateddehumidificationheatpumpairconditioningcycle AT getianshu experimentalinvestigationundersummerconditionsonnovelintegrateddehumidificationheatpumpairconditioningcycle |