An efficient 3D column-only P300 speller paradigm utilizing few numbers of electrodes and flashings for practical BCI implementation.

The event related P300 potentials, positive waveforms in electroencephalography (EEG) signals, are often utilized in brain computer interfaces (BCI). Many studies have been carried out to improve the performance of P300 speller systems either by developing signal processing algorithms and classifier...

Full description

Saved in:
Bibliographic Details
Main Authors: Onur Erdem Korkmaz, Onder Aydemir, Emin Argun Oral, Ibrahim Yucel Ozbek
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2022-01-01
Series:PLoS ONE
Online Access:https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0265904&type=printable
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850233619825557504
author Onur Erdem Korkmaz
Onder Aydemir
Emin Argun Oral
Ibrahim Yucel Ozbek
author_facet Onur Erdem Korkmaz
Onder Aydemir
Emin Argun Oral
Ibrahim Yucel Ozbek
author_sort Onur Erdem Korkmaz
collection DOAJ
description The event related P300 potentials, positive waveforms in electroencephalography (EEG) signals, are often utilized in brain computer interfaces (BCI). Many studies have been carried out to improve the performance of P300 speller systems either by developing signal processing algorithms and classifiers with different architectures or by designing new paradigms. In this study, a new paradigm is proposed for this purpose. The proposed paradigm combines two remarkable properties of being a 3D animation and utilizing column-only flashings as opposed to classical paradigms which are based on row-column flashings in 2D manner. The new paradigm is utilized in a traditional two-layer artificial neural networks model with a single output neuron, and numerous experiments are conducted to evaluate and compare the performance of the proposed paradigm with that of the classical approach. The experimental results, including statistical significance tests, are presented for single and multiple EEG electrode usage combinations in 1, 3 and 15 flashing repetitions to detect P300 waves as well as to recognize target characters. Using the proposed paradigm, the best average classification accuracy rates on the test data are improved from 89.97% to 93.90% (an improvement of 4.36%) for 1 flashing, from 97.11% to 98.10% (an improvement of 1.01%) for 3 flashings and from 99.70% to 99.81% (an improvement of 0.11%) for 15 flashings when all electrodes, included in the study, are utilized. On the other hand, the accuracy rates are improved by 9.69% for 1 flashing, 4.72% for 3 flashings and 1.73% for 15 flashings when the proposed paradigm is utilized with a single EEG electrode (P8). It is observed that the proposed speller paradigm is especially useful in BCI systems designed for few EEG electrodes usage, and hence, it is more suitable for practical implementations. Moreover, all participants, given a subjective test, declared that the proposed paradigm is more user-friendly than classical ones.
format Article
id doaj-art-1b5f526d874945928575e0a412b57bd2
institution OA Journals
issn 1932-6203
language English
publishDate 2022-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-1b5f526d874945928575e0a412b57bd22025-08-20T02:02:53ZengPublic Library of Science (PLoS)PLoS ONE1932-62032022-01-01174e026590410.1371/journal.pone.0265904An efficient 3D column-only P300 speller paradigm utilizing few numbers of electrodes and flashings for practical BCI implementation.Onur Erdem KorkmazOnder AydemirEmin Argun OralIbrahim Yucel OzbekThe event related P300 potentials, positive waveforms in electroencephalography (EEG) signals, are often utilized in brain computer interfaces (BCI). Many studies have been carried out to improve the performance of P300 speller systems either by developing signal processing algorithms and classifiers with different architectures or by designing new paradigms. In this study, a new paradigm is proposed for this purpose. The proposed paradigm combines two remarkable properties of being a 3D animation and utilizing column-only flashings as opposed to classical paradigms which are based on row-column flashings in 2D manner. The new paradigm is utilized in a traditional two-layer artificial neural networks model with a single output neuron, and numerous experiments are conducted to evaluate and compare the performance of the proposed paradigm with that of the classical approach. The experimental results, including statistical significance tests, are presented for single and multiple EEG electrode usage combinations in 1, 3 and 15 flashing repetitions to detect P300 waves as well as to recognize target characters. Using the proposed paradigm, the best average classification accuracy rates on the test data are improved from 89.97% to 93.90% (an improvement of 4.36%) for 1 flashing, from 97.11% to 98.10% (an improvement of 1.01%) for 3 flashings and from 99.70% to 99.81% (an improvement of 0.11%) for 15 flashings when all electrodes, included in the study, are utilized. On the other hand, the accuracy rates are improved by 9.69% for 1 flashing, 4.72% for 3 flashings and 1.73% for 15 flashings when the proposed paradigm is utilized with a single EEG electrode (P8). It is observed that the proposed speller paradigm is especially useful in BCI systems designed for few EEG electrodes usage, and hence, it is more suitable for practical implementations. Moreover, all participants, given a subjective test, declared that the proposed paradigm is more user-friendly than classical ones.https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0265904&type=printable
spellingShingle Onur Erdem Korkmaz
Onder Aydemir
Emin Argun Oral
Ibrahim Yucel Ozbek
An efficient 3D column-only P300 speller paradigm utilizing few numbers of electrodes and flashings for practical BCI implementation.
PLoS ONE
title An efficient 3D column-only P300 speller paradigm utilizing few numbers of electrodes and flashings for practical BCI implementation.
title_full An efficient 3D column-only P300 speller paradigm utilizing few numbers of electrodes and flashings for practical BCI implementation.
title_fullStr An efficient 3D column-only P300 speller paradigm utilizing few numbers of electrodes and flashings for practical BCI implementation.
title_full_unstemmed An efficient 3D column-only P300 speller paradigm utilizing few numbers of electrodes and flashings for practical BCI implementation.
title_short An efficient 3D column-only P300 speller paradigm utilizing few numbers of electrodes and flashings for practical BCI implementation.
title_sort efficient 3d column only p300 speller paradigm utilizing few numbers of electrodes and flashings for practical bci implementation
url https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0265904&type=printable
work_keys_str_mv AT onurerdemkorkmaz anefficient3dcolumnonlyp300spellerparadigmutilizingfewnumbersofelectrodesandflashingsforpracticalbciimplementation
AT onderaydemir anefficient3dcolumnonlyp300spellerparadigmutilizingfewnumbersofelectrodesandflashingsforpracticalbciimplementation
AT eminargunoral anefficient3dcolumnonlyp300spellerparadigmutilizingfewnumbersofelectrodesandflashingsforpracticalbciimplementation
AT ibrahimyucelozbek anefficient3dcolumnonlyp300spellerparadigmutilizingfewnumbersofelectrodesandflashingsforpracticalbciimplementation
AT onurerdemkorkmaz efficient3dcolumnonlyp300spellerparadigmutilizingfewnumbersofelectrodesandflashingsforpracticalbciimplementation
AT onderaydemir efficient3dcolumnonlyp300spellerparadigmutilizingfewnumbersofelectrodesandflashingsforpracticalbciimplementation
AT eminargunoral efficient3dcolumnonlyp300spellerparadigmutilizingfewnumbersofelectrodesandflashingsforpracticalbciimplementation
AT ibrahimyucelozbek efficient3dcolumnonlyp300spellerparadigmutilizingfewnumbersofelectrodesandflashingsforpracticalbciimplementation