Data center energy efficiency case and energy saving operation
PUE value is the key indicator of energy efficiency in data center.Through the comparative analysis of refrigeration efficiency,cooling efficiency,energy conversion efficiency and energy transmission efficiency,the reasons for difference in PUE between two data center cases were found.Three measures...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | zho |
Published: |
Beijing Xintong Media Co., Ltd
2019-02-01
|
Series: | Dianxin kexue |
Subjects: | |
Online Access: | http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2019036/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841530426102906880 |
---|---|
author | Jieliang LOU |
author_facet | Jieliang LOU |
author_sort | Jieliang LOU |
collection | DOAJ |
description | PUE value is the key indicator of energy efficiency in data center.Through the comparative analysis of refrigeration efficiency,cooling efficiency,energy conversion efficiency and energy transmission efficiency,the reasons for difference in PUE between two data center cases were found.Three measures on the strategy of energy-saving operation of data center were put forward,as to control the number of refrigerators,to reduce the temperature of cooling water and to raise the temperature of chilled water.Some inspirations on energy saving in the construction and operation of the data center were raised. |
format | Article |
id | doaj-art-1b2781ef22ce4a6396d814c7f1808455 |
institution | Kabale University |
issn | 1000-0801 |
language | zho |
publishDate | 2019-02-01 |
publisher | Beijing Xintong Media Co., Ltd |
record_format | Article |
series | Dianxin kexue |
spelling | doaj-art-1b2781ef22ce4a6396d814c7f18084552025-01-15T03:03:21ZzhoBeijing Xintong Media Co., LtdDianxin kexue1000-08012019-02-01359510459591159Data center energy efficiency case and energy saving operationJieliang LOUPUE value is the key indicator of energy efficiency in data center.Through the comparative analysis of refrigeration efficiency,cooling efficiency,energy conversion efficiency and energy transmission efficiency,the reasons for difference in PUE between two data center cases were found.Three measures on the strategy of energy-saving operation of data center were put forward,as to control the number of refrigerators,to reduce the temperature of cooling water and to raise the temperature of chilled water.Some inspirations on energy saving in the construction and operation of the data center were raised.http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2019036/PUEenergy efficiencyinfrastructureenergy saving strategy |
spellingShingle | Jieliang LOU Data center energy efficiency case and energy saving operation Dianxin kexue PUE energy efficiency infrastructure energy saving strategy |
title | Data center energy efficiency case and energy saving operation |
title_full | Data center energy efficiency case and energy saving operation |
title_fullStr | Data center energy efficiency case and energy saving operation |
title_full_unstemmed | Data center energy efficiency case and energy saving operation |
title_short | Data center energy efficiency case and energy saving operation |
title_sort | data center energy efficiency case and energy saving operation |
topic | PUE energy efficiency infrastructure energy saving strategy |
url | http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2019036/ |
work_keys_str_mv | AT jielianglou datacenterenergyefficiencycaseandenergysavingoperation |