An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation

Massive air-conditioner resources on the consumer side have a huge potential to be involved in system frequency control, and massive scattered individual air-conditioners can be aggregated into air-conditioner groups to participate in system automatic generation control (AGC). As the operating statu...

Full description

Saved in:
Bibliographic Details
Main Author: NIE Shihao, CHEN Lei, HAO Ling, XU Fei, MIN Yong, DOU Zhenlan, ZHANG Chunyan, SUN Pei
Format: Article
Language:zho
Published: Editorial Office of Journal of Shanghai Jiao Tong University 2024-12-01
Series:Shanghai Jiaotong Daxue xuebao
Subjects:
Online Access:https://xuebao.sjtu.edu.cn/article/2024/1006-2467/1006-2467-58-12-1892.shtml
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841543518641717248
author NIE Shihao, CHEN Lei, HAO Ling, XU Fei, MIN Yong, DOU Zhenlan, ZHANG Chunyan, SUN Pei
author_facet NIE Shihao, CHEN Lei, HAO Ling, XU Fei, MIN Yong, DOU Zhenlan, ZHANG Chunyan, SUN Pei
author_sort NIE Shihao, CHEN Lei, HAO Ling, XU Fei, MIN Yong, DOU Zhenlan, ZHANG Chunyan, SUN Pei
collection DOAJ
description Massive air-conditioner resources on the consumer side have a huge potential to be involved in system frequency control, and massive scattered individual air-conditioners can be aggregated into air-conditioner groups to participate in system automatic generation control (AGC). As the operating status of individual air-conditioners is random, it is necessary to accurately evaluate the frequency control reserve capacity of air-conditioner groups. In this paper, a data-driven nonintrusive load disaggregation (NILD) method is proposed to incorporate massive air-conditioner groups into AGC frequency control reserve. First, the proposed method constructs a sequence-to-sequence model to nonintrusively forecast the frequency control reserve capacity of individual air-conditioners. Considering the fact that the participation of air-conditioners in AGC may affect the comfort of users, the feasibility of individual air-conditioners is evaluated to participate in AGC frequency control and a selection mechanism is constructed to determine whether they can be included in the frequency control reserve of air-conditioner groups. In the proposed method, individual air-conditioners within a sub-station that participate in AGC are aggregated to derive the air-conditioner group frequency control reserve of the sub-station, and the air-conditioner group frequency control reserve of all sub-stations are aggregated to derive the entire air-conditioner group frequency control reserve. The experiments simulate different degrees of system frequency drops in which air-conditioner groups work cooperatively with thermal units for AGC frequency control. The simulation results demonstrate the validity of the proposed method.
format Article
id doaj-art-1b2572c508284e5cb8aae20078d6d653
institution Kabale University
issn 1006-2467
language zho
publishDate 2024-12-01
publisher Editorial Office of Journal of Shanghai Jiao Tong University
record_format Article
series Shanghai Jiaotong Daxue xuebao
spelling doaj-art-1b2572c508284e5cb8aae20078d6d6532025-01-13T09:57:55ZzhoEditorial Office of Journal of Shanghai Jiao Tong UniversityShanghai Jiaotong Daxue xuebao1006-24672024-12-0158121892190210.16183/j.cnki.jsjtu.2023.099An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load DisaggregationNIE Shihao, CHEN Lei, HAO Ling, XU Fei, MIN Yong, DOU Zhenlan, ZHANG Chunyan, SUN Pei01. Department of Electrical Engineering, Tsinghua University, Beijing 100084, China;2. State Grid Shanghai Municipal Electric Power Company, Shanghai 200223, China;3. State Grid Shanghai Electric Power Research Institute, Shanghai 200437, ChinaMassive air-conditioner resources on the consumer side have a huge potential to be involved in system frequency control, and massive scattered individual air-conditioners can be aggregated into air-conditioner groups to participate in system automatic generation control (AGC). As the operating status of individual air-conditioners is random, it is necessary to accurately evaluate the frequency control reserve capacity of air-conditioner groups. In this paper, a data-driven nonintrusive load disaggregation (NILD) method is proposed to incorporate massive air-conditioner groups into AGC frequency control reserve. First, the proposed method constructs a sequence-to-sequence model to nonintrusively forecast the frequency control reserve capacity of individual air-conditioners. Considering the fact that the participation of air-conditioners in AGC may affect the comfort of users, the feasibility of individual air-conditioners is evaluated to participate in AGC frequency control and a selection mechanism is constructed to determine whether they can be included in the frequency control reserve of air-conditioner groups. In the proposed method, individual air-conditioners within a sub-station that participate in AGC are aggregated to derive the air-conditioner group frequency control reserve of the sub-station, and the air-conditioner group frequency control reserve of all sub-stations are aggregated to derive the entire air-conditioner group frequency control reserve. The experiments simulate different degrees of system frequency drops in which air-conditioner groups work cooperatively with thermal units for AGC frequency control. The simulation results demonstrate the validity of the proposed method.https://xuebao.sjtu.edu.cn/article/2024/1006-2467/1006-2467-58-12-1892.shtmlautomatic generation control (agc) frequency controlair conditioner groupsload forecastingnonintrusive load disaggregation (nild)
spellingShingle NIE Shihao, CHEN Lei, HAO Ling, XU Fei, MIN Yong, DOU Zhenlan, ZHANG Chunyan, SUN Pei
An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation
Shanghai Jiaotong Daxue xuebao
automatic generation control (agc) frequency control
air conditioner groups
load forecasting
nonintrusive load disaggregation (nild)
title An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation
title_full An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation
title_fullStr An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation
title_full_unstemmed An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation
title_short An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation
title_sort agc frequency control reserve capacity evaluation method for air conditioner groups based on nonintrusive load disaggregation
topic automatic generation control (agc) frequency control
air conditioner groups
load forecasting
nonintrusive load disaggregation (nild)
url https://xuebao.sjtu.edu.cn/article/2024/1006-2467/1006-2467-58-12-1892.shtml
work_keys_str_mv AT nieshihaochenleihaolingxufeiminyongdouzhenlanzhangchunyansunpei anagcfrequencycontrolreservecapacityevaluationmethodforairconditionergroupsbasedonnonintrusiveloaddisaggregation
AT nieshihaochenleihaolingxufeiminyongdouzhenlanzhangchunyansunpei agcfrequencycontrolreservecapacityevaluationmethodforairconditionergroupsbasedonnonintrusiveloaddisaggregation