Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist Device

Continuous-flow left ventricular assist devices (LVAD) are increasingly used as destination therapy in patients with end-stage heart failure and, with recent improvements in pump design, adverse event rates are decreasing. Implanted patients experience improved survival, quality of life (QoL) and fu...

Full description

Saved in:
Bibliographic Details
Main Authors: Kiran K Mirza, Finn Gustafsson
Format: Article
Language:English
Published: Radcliffe Medical Media 2020-10-01
Series:Cardiac Failure Review
Online Access:https://www.cfrjournal.com/articles/determinants-of-functional-capacity
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850104270126317568
author Kiran K Mirza
Finn Gustafsson
author_facet Kiran K Mirza
Finn Gustafsson
author_sort Kiran K Mirza
collection DOAJ
description Continuous-flow left ventricular assist devices (LVAD) are increasingly used as destination therapy in patients with end-stage heart failure and, with recent improvements in pump design, adverse event rates are decreasing. Implanted patients experience improved survival, quality of life (QoL) and functional capacity (FC). However, improvement in FC and QoL after implantation is not unequivocal, and this has implications for patient selection and preimplantation discussions with patients and relatives. This article identifies preimplantation predictors of lack of improvement in FC and QoL after continuous-flow LVAD implantation and discusses potential mechanisms, allowing for the identification of potential factors that can be modified. In particular, the pathophysiology behind insufficient improvement in peak oxygen uptake is discussed. Data are included from 40 studies, resulting in analysis of >700 exercise tests. Mean peak oxygen uptake was 13.4 ml/kg/min (equivalent to 48% of predicted value; 259 days after implantation, range 31–1,017 days) and mean 6-minute walk test distance was 370 m (182 days after implantation, range 43–543 days). Finally, the interplay between improvement in FC and QoL is discussed.
format Article
id doaj-art-1b08087001504db085ec2c909bcfc1e5
institution DOAJ
issn 2057-7540
2057-7559
language English
publishDate 2020-10-01
publisher Radcliffe Medical Media
record_format Article
series Cardiac Failure Review
spelling doaj-art-1b08087001504db085ec2c909bcfc1e52025-08-20T02:39:22ZengRadcliffe Medical MediaCardiac Failure Review2057-75402057-75592020-10-01610.15420/cfr.2020.15Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist DeviceKiran K Mirza0Finn Gustafsson1Department of Cardiology, Rigshospitalet, Copenhagen, DenmarkDepartment of Cardiology, Rigshospitalet, Copenhagen, DenmarkContinuous-flow left ventricular assist devices (LVAD) are increasingly used as destination therapy in patients with end-stage heart failure and, with recent improvements in pump design, adverse event rates are decreasing. Implanted patients experience improved survival, quality of life (QoL) and functional capacity (FC). However, improvement in FC and QoL after implantation is not unequivocal, and this has implications for patient selection and preimplantation discussions with patients and relatives. This article identifies preimplantation predictors of lack of improvement in FC and QoL after continuous-flow LVAD implantation and discusses potential mechanisms, allowing for the identification of potential factors that can be modified. In particular, the pathophysiology behind insufficient improvement in peak oxygen uptake is discussed. Data are included from 40 studies, resulting in analysis of >700 exercise tests. Mean peak oxygen uptake was 13.4 ml/kg/min (equivalent to 48% of predicted value; 259 days after implantation, range 31–1,017 days) and mean 6-minute walk test distance was 370 m (182 days after implantation, range 43–543 days). Finally, the interplay between improvement in FC and QoL is discussed.https://www.cfrjournal.com/articles/determinants-of-functional-capacity
spellingShingle Kiran K Mirza
Finn Gustafsson
Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist Device
Cardiac Failure Review
title Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist Device
title_full Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist Device
title_fullStr Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist Device
title_full_unstemmed Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist Device
title_short Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist Device
title_sort determinants of functional capacity and quality of life after implantation of a durable left ventricular assist device
url https://www.cfrjournal.com/articles/determinants-of-functional-capacity
work_keys_str_mv AT kirankmirza determinantsoffunctionalcapacityandqualityoflifeafterimplantationofadurableleftventricularassistdevice
AT finngustafsson determinantsoffunctionalcapacityandqualityoflifeafterimplantationofadurableleftventricularassistdevice