Evaluation of Dielectric Reliability in Oil-Insulated Transformers Using Scilab: Impact of Temperature and Electric Field Frequency
This article presents a study on the dielectric behavior of insulating oil in power transformers, using Scilab simulations as a primary tool. The research aims to analyze the impact of temperature, electric field frequency, and oil aging on dielectric properties like relative permittivity and dielec...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidad Tecnológica de La Habana, José Antonio Echeverría
2024-09-01
|
Series: | Revista Científica de Ingeniería Energética |
Subjects: | |
Online Access: | https://rie.cujae.edu.cu/index.php/RIE/article/view/910/1002 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841556025152372736 |
---|---|
author | Maykop Pérez Martínez Josnier Ramos Guardarrama |
author_facet | Maykop Pérez Martínez Josnier Ramos Guardarrama |
author_sort | Maykop Pérez Martínez |
collection | DOAJ |
description | This article presents a study on the dielectric behavior of insulating oil in power transformers, using Scilab simulations as a primary tool. The research aims to analyze the impact of temperature, electric field frequency, and oil aging on dielectric properties like relative permittivity and dielectric strength. The study is crucial for transformers' operation and lifespan, as deteriorating dielectric properties can lead to failures and costly service interruptions. The study uses Scilab simulation to model and evaluate transformer insulation systems under different conditions, allowing for prediction of performance under different electrical stresses. The results provide valuable insights for transformer design, optimization, and diagnosis, contributing to a better understanding of insulating oil behavior. The findings also offer tools for developing more efficient equipment and implementing predictive maintenance strategies, ensuring continuity of electrical service and minimizing operational costs. |
format | Article |
id | doaj-art-1a35533fd9b14e1d86eef3448f1e2584 |
institution | Kabale University |
issn | 1815-5901 |
language | English |
publishDate | 2024-09-01 |
publisher | Universidad Tecnológica de La Habana, José Antonio Echeverría |
record_format | Article |
series | Revista Científica de Ingeniería Energética |
spelling | doaj-art-1a35533fd9b14e1d86eef3448f1e25842025-01-07T14:48:39ZengUniversidad Tecnológica de La Habana, José Antonio EcheverríaRevista Científica de Ingeniería Energética1815-59012024-09-01453110Evaluation of Dielectric Reliability in Oil-Insulated Transformers Using Scilab: Impact of Temperature and Electric Field FrequencyMaykop Pérez Martínez0https://orcid.org/0000-0003-3073-1675Josnier Ramos Guardarrama1https://orcid.org/0000-0002-8796-8481University of Concepción, ChileTechnological University of Havana "José Antonio Echeverria", CUJAE. La Habana,This article presents a study on the dielectric behavior of insulating oil in power transformers, using Scilab simulations as a primary tool. The research aims to analyze the impact of temperature, electric field frequency, and oil aging on dielectric properties like relative permittivity and dielectric strength. The study is crucial for transformers' operation and lifespan, as deteriorating dielectric properties can lead to failures and costly service interruptions. The study uses Scilab simulation to model and evaluate transformer insulation systems under different conditions, allowing for prediction of performance under different electrical stresses. The results provide valuable insights for transformer design, optimization, and diagnosis, contributing to a better understanding of insulating oil behavior. The findings also offer tools for developing more efficient equipment and implementing predictive maintenance strategies, ensuring continuity of electrical service and minimizing operational costs.https://rie.cujae.edu.cu/index.php/RIE/article/view/910/1002dielectric behaviorfrequency and temperatureoil-insulated transformersrelative permittivityscilab |
spellingShingle | Maykop Pérez Martínez Josnier Ramos Guardarrama Evaluation of Dielectric Reliability in Oil-Insulated Transformers Using Scilab: Impact of Temperature and Electric Field Frequency Revista Científica de Ingeniería Energética dielectric behavior frequency and temperature oil-insulated transformers relative permittivity scilab |
title | Evaluation of Dielectric Reliability in Oil-Insulated Transformers Using Scilab: Impact of Temperature and Electric Field Frequency |
title_full | Evaluation of Dielectric Reliability in Oil-Insulated Transformers Using Scilab: Impact of Temperature and Electric Field Frequency |
title_fullStr | Evaluation of Dielectric Reliability in Oil-Insulated Transformers Using Scilab: Impact of Temperature and Electric Field Frequency |
title_full_unstemmed | Evaluation of Dielectric Reliability in Oil-Insulated Transformers Using Scilab: Impact of Temperature and Electric Field Frequency |
title_short | Evaluation of Dielectric Reliability in Oil-Insulated Transformers Using Scilab: Impact of Temperature and Electric Field Frequency |
title_sort | evaluation of dielectric reliability in oil insulated transformers using scilab impact of temperature and electric field frequency |
topic | dielectric behavior frequency and temperature oil-insulated transformers relative permittivity scilab |
url | https://rie.cujae.edu.cu/index.php/RIE/article/view/910/1002 |
work_keys_str_mv | AT maykopperezmartinez evaluationofdielectricreliabilityinoilinsulatedtransformersusingscilabimpactoftemperatureandelectricfieldfrequency AT josnierramosguardarrama evaluationofdielectricreliabilityinoilinsulatedtransformersusingscilabimpactoftemperatureandelectricfieldfrequency |