Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study

A study was carried out to investigate compatibility of amlodipine besylate and olmesartan medoxomil with a variety of pharmaceutical excipients. Both drugs are antihypertensive agents that can be administered alone, in monotherapy, or in pharmaceutical association. The studies were performed using...

Full description

Saved in:
Bibliographic Details
Main Authors: Ariadne M. Brondi, Jerusa S. Garcia, Marcello G. Trevisan
Format: Article
Language:English
Published: Wiley 2017-01-01
Series:Journal of Analytical Methods in Chemistry
Online Access:http://dx.doi.org/10.1155/2017/4878316
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850236389632770048
author Ariadne M. Brondi
Jerusa S. Garcia
Marcello G. Trevisan
author_facet Ariadne M. Brondi
Jerusa S. Garcia
Marcello G. Trevisan
author_sort Ariadne M. Brondi
collection DOAJ
description A study was carried out to investigate compatibility of amlodipine besylate and olmesartan medoxomil with a variety of pharmaceutical excipients. Both drugs are antihypertensive agents that can be administered alone, in monotherapy, or in pharmaceutical association. The studies were performed using binary and ternary mixtures, and samples were stored for 3 and 6 months at 40°C under 75% relative humidity and dry conditions. For this study, a method based on high-performance liquid chromatography (HPLC) was developed and validated for the simultaneous determination of amlodipine besylate and olmesartan medoxomil in samples from pharmaceutical preformulation studies using diode array detector (DAD) and charged aerosol detector (CAD). The runtime per sample was 10 min with retention time of 7.926 min and 4.408 min for amlodipine and olmesartan, respectively. The validation was performed according to ICH guidelines. The calibration curve presents linear dynamic range from 12 to 250 μg mL−1 for amlodipine and from 25 to 500 μg mL−1 for olmesartan with coefficient of determination (R2 ≥ 0.9908) while repeatability and reproducibility (expressed as relative standard deviation) were lower than 1.0%. The excipients such as corn starch, croscarmellose sodium, magnesium stearate, polyvinyl alcohol, talc, polyvinylpyrrolidone, lactose monohydrate, and polyethylene glycol showed potential incompatibilities after accelerated stability testing.
format Article
id doaj-art-19fae883a1cc443bb6a6aa9c291a3f3b
institution OA Journals
issn 2090-8865
2090-8873
language English
publishDate 2017-01-01
publisher Wiley
record_format Article
series Journal of Analytical Methods in Chemistry
spelling doaj-art-19fae883a1cc443bb6a6aa9c291a3f3b2025-08-20T02:01:58ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732017-01-01201710.1155/2017/48783164878316Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility StudyAriadne M. Brondi0Jerusa S. Garcia1Marcello G. Trevisan2LACFar-Institute of Chemistry, Federal University of Alfenas (UNIFAL-MG), Alfenas, MG, BrazilLACFar-Institute of Chemistry, Federal University of Alfenas (UNIFAL-MG), Alfenas, MG, BrazilLACFar-Institute of Chemistry, Federal University of Alfenas (UNIFAL-MG), Alfenas, MG, BrazilA study was carried out to investigate compatibility of amlodipine besylate and olmesartan medoxomil with a variety of pharmaceutical excipients. Both drugs are antihypertensive agents that can be administered alone, in monotherapy, or in pharmaceutical association. The studies were performed using binary and ternary mixtures, and samples were stored for 3 and 6 months at 40°C under 75% relative humidity and dry conditions. For this study, a method based on high-performance liquid chromatography (HPLC) was developed and validated for the simultaneous determination of amlodipine besylate and olmesartan medoxomil in samples from pharmaceutical preformulation studies using diode array detector (DAD) and charged aerosol detector (CAD). The runtime per sample was 10 min with retention time of 7.926 min and 4.408 min for amlodipine and olmesartan, respectively. The validation was performed according to ICH guidelines. The calibration curve presents linear dynamic range from 12 to 250 μg mL−1 for amlodipine and from 25 to 500 μg mL−1 for olmesartan with coefficient of determination (R2 ≥ 0.9908) while repeatability and reproducibility (expressed as relative standard deviation) were lower than 1.0%. The excipients such as corn starch, croscarmellose sodium, magnesium stearate, polyvinyl alcohol, talc, polyvinylpyrrolidone, lactose monohydrate, and polyethylene glycol showed potential incompatibilities after accelerated stability testing.http://dx.doi.org/10.1155/2017/4878316
spellingShingle Ariadne M. Brondi
Jerusa S. Garcia
Marcello G. Trevisan
Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study
Journal of Analytical Methods in Chemistry
title Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study
title_full Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study
title_fullStr Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study
title_full_unstemmed Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study
title_short Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study
title_sort development and validation of a chromatography method using tandem uv charged aerosol detector for simultaneous determination of amlodipine besylate and olmesartan medoxomil application to drug excipient compatibility study
url http://dx.doi.org/10.1155/2017/4878316
work_keys_str_mv AT ariadnembrondi developmentandvalidationofachromatographymethodusingtandemuvchargedaerosoldetectorforsimultaneousdeterminationofamlodipinebesylateandolmesartanmedoxomilapplicationtodrugexcipientcompatibilitystudy
AT jerusasgarcia developmentandvalidationofachromatographymethodusingtandemuvchargedaerosoldetectorforsimultaneousdeterminationofamlodipinebesylateandolmesartanmedoxomilapplicationtodrugexcipientcompatibilitystudy
AT marcellogtrevisan developmentandvalidationofachromatographymethodusingtandemuvchargedaerosoldetectorforsimultaneousdeterminationofamlodipinebesylateandolmesartanmedoxomilapplicationtodrugexcipientcompatibilitystudy