Realistic Monte Carlo simulation of the INOR Therapy Unit and electron contamination calculation for a board 60Co Beam

The therapy beam from the 60Co unit used at INOR was modeled using the EGS Monte Carlo radiation transport system. The rectangular geometry of the collimating system is fully simulated and the effect of considering the outer collimator a set of stepped collimators rather than a collimator with a sm...

Full description

Saved in:
Bibliographic Details
Main Authors: J. Ernesto Mainegra, Roberto Capote
Format: Article
Language:English
Published: Instituto Tecnológico de Costa Rica 2016-11-01
Series:Tecnología en Marcha
Online Access:https://revistas.tec.ac.cr/index.php/tec_marcha/article/view/2858
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849304254632689664
author J. Ernesto Mainegra
Roberto Capote
author_facet J. Ernesto Mainegra
Roberto Capote
author_sort J. Ernesto Mainegra
collection DOAJ
description The therapy beam from the 60Co unit used at INOR was modeled using the EGS Monte Carlo radiation transport system. The rectangular geometry of the collimating system is fully simulated and the effect of considering the outer collimator a set of stepped collimators rather than a collimator with a smooth surface was estimated. Variance reduction techniques are widely used to increase the efficiency of our calculations. Even for the dose at very shallow depths (<0.5 mm) the agreement of our calculations with the experimental results is very good. The shift of peak dose to about 1 mm due to electron contamination is observed.
format Article
id doaj-art-194c981bea9e4c5fafbbccd8321078d5
institution Kabale University
issn 0379-3982
2215-3241
language English
publishDate 2016-11-01
publisher Instituto Tecnológico de Costa Rica
record_format Article
series Tecnología en Marcha
spelling doaj-art-194c981bea9e4c5fafbbccd8321078d52025-08-20T03:55:45ZengInstituto Tecnológico de Costa RicaTecnología en Marcha0379-39822215-32412016-11-0113Realistic Monte Carlo simulation of the INOR Therapy Unit and electron contamination calculation for a board 60Co BeamJ. Ernesto MainegraRoberto Capote The therapy beam from the 60Co unit used at INOR was modeled using the EGS Monte Carlo radiation transport system. The rectangular geometry of the collimating system is fully simulated and the effect of considering the outer collimator a set of stepped collimators rather than a collimator with a smooth surface was estimated. Variance reduction techniques are widely used to increase the efficiency of our calculations. Even for the dose at very shallow depths (<0.5 mm) the agreement of our calculations with the experimental results is very good. The shift of peak dose to about 1 mm due to electron contamination is observed. https://revistas.tec.ac.cr/index.php/tec_marcha/article/view/2858
spellingShingle J. Ernesto Mainegra
Roberto Capote
Realistic Monte Carlo simulation of the INOR Therapy Unit and electron contamination calculation for a board 60Co Beam
Tecnología en Marcha
title Realistic Monte Carlo simulation of the INOR Therapy Unit and electron contamination calculation for a board 60Co Beam
title_full Realistic Monte Carlo simulation of the INOR Therapy Unit and electron contamination calculation for a board 60Co Beam
title_fullStr Realistic Monte Carlo simulation of the INOR Therapy Unit and electron contamination calculation for a board 60Co Beam
title_full_unstemmed Realistic Monte Carlo simulation of the INOR Therapy Unit and electron contamination calculation for a board 60Co Beam
title_short Realistic Monte Carlo simulation of the INOR Therapy Unit and electron contamination calculation for a board 60Co Beam
title_sort realistic monte carlo simulation of the inor therapy unit and electron contamination calculation for a board 60co beam
url https://revistas.tec.ac.cr/index.php/tec_marcha/article/view/2858
work_keys_str_mv AT jernestomainegra realisticmontecarlosimulationoftheinortherapyunitandelectroncontaminationcalculationforaboard60cobeam
AT robertocapote realisticmontecarlosimulationoftheinortherapyunitandelectroncontaminationcalculationforaboard60cobeam