The Characteristic Improvement of Electromagnetic Proportional Directional Control Valve

The electromagnetic proportional directional control valve is widely used in hydraulic control system and its typical faults are not enough electromagnetic force and too high temperature rise to burn out the coil. The magnetic field and coil temperature field distribution of the control valve are mo...

Full description

Saved in:
Bibliographic Details
Main Author: Hua Zhang
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Journal of Control Science and Engineering
Online Access:http://dx.doi.org/10.1155/2018/3582454
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The electromagnetic proportional directional control valve is widely used in hydraulic control system and its typical faults are not enough electromagnetic force and too high temperature rise to burn out the coil. The magnetic field and coil temperature field distribution of the control valve are modeled and analyzed by using the finite element method. The influence laws of the geometry and parameters on electromagnetic force are analyzed. Furthermore, the influence of coil control current and heat transfer coefficient on the temperature rise of coil is analyzed, which provides a theoretical basis for the reliability optimization design of electromagnetic proportional directional control valve.
ISSN:1687-5249