Three-dimensional finite element analysis of factors affecting stability of anchorage in zygomatic alveolar ridge
Objective To investigate the influence of micro-implant length and screw angle on stress distribution and displacement of micro-implant bone interface when micro-implant was implanted in zygomatic alveolar ridge and bear a certain load, in order to provide certain theoretical basis for micro-implant...
Saved in:
| Main Author: | LIU Ke, XUAN Shijie, LIU Xin |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Office of Stomatology
2025-02-01
|
| Series: | Kouqiang yixue |
| Subjects: | |
| Online Access: | https://www.stomatology.cn/fileup/1003-9872/PDF/1740535883599-662338422.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Three-dimensional finite element analysis of implant positioning protocols in the maxillary sinus region for zygomatic bone implantation
by: LI Jing, et al.
Published: (2024-10-01) -
Finite element study on the stress of hole sealing resin in screw approach of dental implant
by: LI Feifan, WU Meiqi, BI Mengfei, SHEN Ming
Published: (2025-06-01) -
Time-history simulation of civil architecture earthquake disaster relief- based on the three-dimensional dynamic finite element method
by: Liu Bing, et al.
Published: (2014-09-01) -
Biomechanical evaluation of conventional, zygomatic, zygomatic bone anchored subperiosteal and maxilla anchored subperiosteal implants applied totally edentulous maxilla: finite element stress analysis
by: Berivan Deniz, et al.
Published: (2025-07-01) -
Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software
by: Jiwon Park, et al.
Published: (2024-12-01)