Robot-assisted thoracoscopic repair of tracheal gunshot wound

A 23-year-old man suffered two gunshot wounds and upon arrival to the emergency room was found on imaging to have a large pneumothorax with considerable subcutaneous emphysema. Intubation and placement of bilateral chest tubes did not improve the patient's oxygenation; bronchoscopy revealed a 1...

Full description

Saved in:
Bibliographic Details
Main Authors: Antoine Nehme, Salman Zaheer, Alexander Leung
Format: Article
Language:English
Published: Elsevier 2024-06-01
Series:Trauma Case Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352644024000463
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A 23-year-old man suffered two gunshot wounds and upon arrival to the emergency room was found on imaging to have a large pneumothorax with considerable subcutaneous emphysema. Intubation and placement of bilateral chest tubes did not improve the patient's oxygenation; bronchoscopy revealed a 1 cm tracheal defect in the membranous wall 4 cm proximal to the carina. The patient underwent robot-assisted primary repair of the tracheal injury with a #3-0 PDS Stratafix barbed suture buttressed with an intercostal muscle flap. The patient was discharged in good condition on post-operative day 17, with follow-up bronchoscopy showing complete healing of the trachea.