Criteria for equipment defects for thermal power substation control system

The present state of diagnostic tools, data transfer and processing allows to create automated system of continuous control of substation equipment based on thermal imagers, permanently installed such as surveillance cameras. There is at least three reasons why such online monitoring systems are use...

Full description

Saved in:
Bibliographic Details
Main Authors: A. D. Zaripova, D. K. Zaripov, A. E. Usachev
Format: Article
Language:English
Published: Kazan State Power Engineering University 2017-12-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/382
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850268671184732160
author A. D. Zaripova
D. K. Zaripov
A. E. Usachev
author_facet A. D. Zaripova
D. K. Zaripov
A. E. Usachev
author_sort A. D. Zaripova
collection DOAJ
description The present state of diagnostic tools, data transfer and processing allows to create automated system of continuous control of substation equipment based on thermal imagers, permanently installed such as surveillance cameras. There is at least three reasons why such online monitoring systems are used: increasing the reliability of the substation by providing timely identification of emerging defects, improving safety by preventing invasion and reducing costs of equipment condition monitoring. The effectiveness of these systems will be determined by an algorithm incorporated in the program to assess the state of substation objects for thermal images. At this research the technique of detection of of electrical equipment defects on the thermal images by identifying local, medium and RMS values of temperature anomalies at different substation objects. For each piece of equipment set the values of excess or excessive temperatures which is determining the degree of fault. For all substation objects in the generally results tabulated. The developed technique can be considered as the basis of technical specifications for program development for the automated thermal imaging system of electrical substation online monitoring in real time.
format Article
id doaj-art-176e810744d04b91b430ba7fa87bc693
institution OA Journals
issn 1998-9903
language English
publishDate 2017-12-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj-art-176e810744d04b91b430ba7fa87bc6932025-08-20T01:53:23ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032017-12-01195-6515710.30724/1998-9903-2017-19-5-6-51-57382Criteria for equipment defects for thermal power substation control systemA. D. Zaripova0D. K. Zaripov1A. E. Usachev2Kazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityThe present state of diagnostic tools, data transfer and processing allows to create automated system of continuous control of substation equipment based on thermal imagers, permanently installed such as surveillance cameras. There is at least three reasons why such online monitoring systems are used: increasing the reliability of the substation by providing timely identification of emerging defects, improving safety by preventing invasion and reducing costs of equipment condition monitoring. The effectiveness of these systems will be determined by an algorithm incorporated in the program to assess the state of substation objects for thermal images. At this research the technique of detection of of electrical equipment defects on the thermal images by identifying local, medium and RMS values of temperature anomalies at different substation objects. For each piece of equipment set the values of excess or excessive temperatures which is determining the degree of fault. For all substation objects in the generally results tabulated. The developed technique can be considered as the basis of technical specifications for program development for the automated thermal imaging system of electrical substation online monitoring in real time.https://www.energyret.ru/jour/article/view/382thermal controlonline monitoring of electrical equipmentthermal methods of diagnosisthe temperature anomalyassessment of fault degree
spellingShingle A. D. Zaripova
D. K. Zaripov
A. E. Usachev
Criteria for equipment defects for thermal power substation control system
Известия высших учебных заведений: Проблемы энергетики
thermal control
online monitoring of electrical equipment
thermal methods of diagnosis
the temperature anomaly
assessment of fault degree
title Criteria for equipment defects for thermal power substation control system
title_full Criteria for equipment defects for thermal power substation control system
title_fullStr Criteria for equipment defects for thermal power substation control system
title_full_unstemmed Criteria for equipment defects for thermal power substation control system
title_short Criteria for equipment defects for thermal power substation control system
title_sort criteria for equipment defects for thermal power substation control system
topic thermal control
online monitoring of electrical equipment
thermal methods of diagnosis
the temperature anomaly
assessment of fault degree
url https://www.energyret.ru/jour/article/view/382
work_keys_str_mv AT adzaripova criteriaforequipmentdefectsforthermalpowersubstationcontrolsystem
AT dkzaripov criteriaforequipmentdefectsforthermalpowersubstationcontrolsystem
AT aeusachev criteriaforequipmentdefectsforthermalpowersubstationcontrolsystem