HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION
A diagram of the heat pump station (HPS) for the central heat supply station of the district heating system, which gets the power from the CHP plant is examined. A block diagram of the control of the system and compressor pressure control system are examined. The description of the control laws of e...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Academy of Sciences of Moldova
2008-04-01
|
| Series: | Problems of the Regional Energetics |
| Subjects: | |
| Online Access: | http://journal.ie.asm.md/assets/files/m71_2_61.doc |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849247890815320064 |
|---|---|
| author | Sit B.M. Juravleov A.A. Sit M.L. |
| author_facet | Sit B.M. Juravleov A.A. Sit M.L. |
| author_sort | Sit B.M. |
| collection | DOAJ |
| description | A diagram of the heat pump station (HPS) for the central heat supply station of the district heating system, which gets the power from the CHP plant is examined. A block diagram of the control of the system and compressor pressure control system are examined. The description of the control laws of evaporator at the variable heat load of the HPS and control laws of the gas cooler taking into account the goal of achieving the maximum of COP of HPS is shown as well. |
| format | Article |
| id | doaj-art-1725a09bcd764cbbbefde18fb643baef |
| institution | Kabale University |
| issn | 1857-0070 |
| language | English |
| publishDate | 2008-04-01 |
| publisher | Academy of Sciences of Moldova |
| record_format | Article |
| series | Problems of the Regional Energetics |
| spelling | doaj-art-1725a09bcd764cbbbefde18fb643baef2025-08-20T03:58:07ZengAcademy of Sciences of MoldovaProblems of the Regional Energetics1857-00702008-04-012008-1118HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATIONSit B.M.0Juravleov A.A.1Sit M.L.2Institute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaA diagram of the heat pump station (HPS) for the central heat supply station of the district heating system, which gets the power from the CHP plant is examined. A block diagram of the control of the system and compressor pressure control system are examined. The description of the control laws of evaporator at the variable heat load of the HPS and control laws of the gas cooler taking into account the goal of achieving the maximum of COP of HPS is shown as well.http://journal.ie.asm.md/assets/files/m71_2_61.docheat pump stationAacontrol law |
| spellingShingle | Sit B.M. Juravleov A.A. Sit M.L. HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION Problems of the Regional Energetics heat pump station A a control law |
| title | HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION |
| title_full | HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION |
| title_fullStr | HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION |
| title_full_unstemmed | HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION |
| title_short | HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION |
| title_sort | heat pump station with carbon dioxide as a working fluid energy efficiency growth in combined district heating system due to its control system optimization |
| topic | heat pump station A a control law |
| url | http://journal.ie.asm.md/assets/files/m71_2_61.doc |
| work_keys_str_mv | AT sitbm heatpumpstationwithcarbondioxideasaworkingfluidenergyefficiencygrowthincombineddistrictheatingsystemduetoitscontrolsystemoptimization AT juravleovaa heatpumpstationwithcarbondioxideasaworkingfluidenergyefficiencygrowthincombineddistrictheatingsystemduetoitscontrolsystemoptimization AT sitml heatpumpstationwithcarbondioxideasaworkingfluidenergyefficiencygrowthincombineddistrictheatingsystemduetoitscontrolsystemoptimization |