The addition of vitamin E could reduce femoral head penetration of the polyethylene liners

Abstract Background Vitamin E-diffused highly cross-linked polyethylene (HXLPE/Vit E) is a relatively advanced material used in total hip arthroplasty (THA) but whether it shows superiority is unclear. Objective This meta-analysis was performed to investigate the effect of HXLPE/Vit E liners in THA....

Full description

Saved in:
Bibliographic Details
Main Authors: Fanxiao Liu, Ling Gao, Dawei Wang, Qingyu Zhang
Format: Article
Language:English
Published: BMC 2025-01-01
Series:Journal of Orthopaedic Surgery and Research
Subjects:
Online Access:https://doi.org/10.1186/s13018-024-05402-7
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background Vitamin E-diffused highly cross-linked polyethylene (HXLPE/Vit E) is a relatively advanced material used in total hip arthroplasty (THA) but whether it shows superiority is unclear. Objective This meta-analysis was performed to investigate the effect of HXLPE/Vit E liners in THA. Methods Medline/PubMed, Embase and Cochrane Library databases were searched to retrieve studies assessing the efficacy of HXLPE/Vit E liners in THA with the design of a randomized, controlled trial. Meta-analyses were conducted to merge the outcome estimates of interest, such as the femoral head penetration (FHP), FHP rate, FHP in x- (medial/lateral), y- (vertical) and z- (anteroposterior) axes, cup inclination angle, Harris hip score (HHS), numeric rating scale (NRS) and complications. Then pooled outcomes at different time points during the follow-up period were calculated. Results Follow an elaborate search of related databases, 23 studies involving a total of 54,920 participants were deemed eligible for this meta-analysis. The pooled results revealed significant decreased FHP at the last follow-up (pooled Mean Difference [MD] = -0.10, 95% confidence intervals [CIs]: -0.14 to -0.06). The subgroup analysis revealed a consistent trend at different time points during the follow-up. Significant decrease in the FHP rate were identified at the postoperative 1–2 years (pooled MD = -0.01, 95% CIs: -0.02 to -0.00) rather than at 2–5, 5–7, and 7–10 years. The combined results of clinical scores demonstrated no significant changes in the HHS, NRS, and EQ-5D variables. Additionally, no significant differences in the revision and cup inclination angle were identified during the follow-up period. Conclusions This study indicated that HXLPE/Vit E liner in total hip arthroplasty may decrease the femoral head penetration, mainly due to the decreased wear in proximal directions. However, no improvement on the clinical functions and complications were identified, and whether HXLPE/Vit E has the potential to prevent implant loosening or revision surgery could not be identified, which requires to be elaborated by high-quality randomized controlled trials.
ISSN:1749-799X