Uncertainty of sound insulation measurement in laboratory

Protection against noise is one of the six essentials requirements of the European Union directive. In buildings airborne sound insulation is used to define the acoustic quality of walls between rooms. However the evaluation of sound insulation /index/ is sometimes difficult or even ambiguous, bo...

Full description

Saved in:
Bibliographic Details
Main Author: Tadeusz Wszołek
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2014-01-01
Series:Archives of Acoustics
Subjects:
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/1420
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849318839583506432
author Tadeusz Wszołek
author_facet Tadeusz Wszołek
author_sort Tadeusz Wszołek
collection DOAJ
description Protection against noise is one of the six essentials requirements of the European Union directive. In buildings airborne sound insulation is used to define the acoustic quality of walls between rooms. However the evaluation of sound insulation /index/ is sometimes difficult or even ambiguous, both in field and laboratory measurements, in spite of the fact that there are some unified measurement procedures specified in the ISO 140 standards. There are problems with the reproducibility and repeatability of the measurement results. Some difficulties may be caused by non-diffuse acoustic fields, non uniform reverberation time or errors of the reverberation time measurements. Some minor problems are also posed by flanking transmission and the S/N ratio. The paper includes an analysis of partial uncertainties of the above mentioned measurement components and their influence on the combined uncertainty in 1/3 octave frequency bands and the sound reduction index determined according to ISO 140-3, using the uncertainty propagation law. All of the analysis and calculations performed in the paper concern the conjugated reverberation rooms and measurement set-up located in AGHUST Department of Mechanics and Vibroacoustics in Kraków.
format Article
id doaj-art-12efc6c7f3d34f2ea43dd9280baf8450
institution Kabale University
issn 0137-5075
2300-262X
language English
publishDate 2014-01-01
publisher Institute of Fundamental Technological Research Polish Academy of Sciences
record_format Article
series Archives of Acoustics
spelling doaj-art-12efc6c7f3d34f2ea43dd9280baf84502025-08-20T03:50:44ZengInstitute of Fundamental Technological Research Polish Academy of SciencesArchives of Acoustics0137-50752300-262X2014-01-01324(S)Uncertainty of sound insulation measurement in laboratoryTadeusz Wszołek0AGH University of Science and Technology, Department of Mechanics and Vibroacoustics, Al. Mickiewicza 30, 30-059 KrakówProtection against noise is one of the six essentials requirements of the European Union directive. In buildings airborne sound insulation is used to define the acoustic quality of walls between rooms. However the evaluation of sound insulation /index/ is sometimes difficult or even ambiguous, both in field and laboratory measurements, in spite of the fact that there are some unified measurement procedures specified in the ISO 140 standards. There are problems with the reproducibility and repeatability of the measurement results. Some difficulties may be caused by non-diffuse acoustic fields, non uniform reverberation time or errors of the reverberation time measurements. Some minor problems are also posed by flanking transmission and the S/N ratio. The paper includes an analysis of partial uncertainties of the above mentioned measurement components and their influence on the combined uncertainty in 1/3 octave frequency bands and the sound reduction index determined according to ISO 140-3, using the uncertainty propagation law. All of the analysis and calculations performed in the paper concern the conjugated reverberation rooms and measurement set-up located in AGHUST Department of Mechanics and Vibroacoustics in Kraków.https://acoustics.ippt.pan.pl/index.php/aa/article/view/1420sound insulationsound reduction indexuncertaintyreverberation room.
spellingShingle Tadeusz Wszołek
Uncertainty of sound insulation measurement in laboratory
Archives of Acoustics
sound insulation
sound reduction index
uncertainty
reverberation room.
title Uncertainty of sound insulation measurement in laboratory
title_full Uncertainty of sound insulation measurement in laboratory
title_fullStr Uncertainty of sound insulation measurement in laboratory
title_full_unstemmed Uncertainty of sound insulation measurement in laboratory
title_short Uncertainty of sound insulation measurement in laboratory
title_sort uncertainty of sound insulation measurement in laboratory
topic sound insulation
sound reduction index
uncertainty
reverberation room.
url https://acoustics.ippt.pan.pl/index.php/aa/article/view/1420
work_keys_str_mv AT tadeuszwszołek uncertaintyofsoundinsulationmeasurementinlaboratory