Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology
This paper addresses issues relating to the temperature stability of impedance infrastructure used for the realization of impedance units and the calibration of measuring instruments. A description of the new infrastructure for impedance metrology recently developed in Poland is provided. We present...
Saved in:
| Main Authors: | , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2025-06-01
|
| Series: | Energies |
| Subjects: | |
| Online Access: | https://www.mdpi.com/1996-1073/18/12/3018 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849433747130155008 |
|---|---|
| author | Marian Kampik Krzysztof Musioł Ryszard Rybski Janusz Kaczmarek Mirosław Kozioł Maciej Koszarny Adam Ziółek Jolanta Jursza Paweł Zawadzki |
| author_facet | Marian Kampik Krzysztof Musioł Ryszard Rybski Janusz Kaczmarek Mirosław Kozioł Maciej Koszarny Adam Ziółek Jolanta Jursza Paweł Zawadzki |
| author_sort | Marian Kampik |
| collection | DOAJ |
| description | This paper addresses issues relating to the temperature stability of impedance infrastructure used for the realization of impedance units and the calibration of measuring instruments. A description of the new infrastructure for impedance metrology recently developed in Poland is provided. We present the results of measurements of temperature coefficients for four-port resistance standards and two-port capacitors used in the permuting capacitor device. We also report the results of stability tests of the recently developed temperature-controlled capacitance set. The results demonstrate excellent temperature stability for the impedance components and serve as an important source of information for selecting environmental conditions during comparisons and routine calibration. |
| format | Article |
| id | doaj-art-12918f5404b64a4db043c6736cd5a55d |
| institution | Kabale University |
| issn | 1996-1073 |
| language | English |
| publishDate | 2025-06-01 |
| publisher | MDPI AG |
| record_format | Article |
| series | Energies |
| spelling | doaj-art-12918f5404b64a4db043c6736cd5a55d2025-08-20T03:26:56ZengMDPI AGEnergies1996-10732025-06-011812301810.3390/en18123018Temperature Dependence of the New Calibration Infrastructure for Impedance MetrologyMarian Kampik0Krzysztof Musioł1Ryszard Rybski2Janusz Kaczmarek3Mirosław Kozioł4Maciej Koszarny5Adam Ziółek6Jolanta Jursza7Paweł Zawadzki8Department of Measurement Science, Electronics and Control, Silesian University of Technology, 44-100 Gliwice, PolandDepartment of Measurement Science, Electronics and Control, Silesian University of Technology, 44-100 Gliwice, PolandInstitute of Measurements, Electronics and Computer Science, University of Zielona Góra, 65-417 Zielona Góra, PolandInstitute of Measurements, Electronics and Computer Science, University of Zielona Góra, 65-417 Zielona Góra, PolandInstitute of Measurements, Electronics and Computer Science, University of Zielona Góra, 65-417 Zielona Góra, PolandElectricity and Radiation Department, Central Office of Measures, 00-139 Warszawa, PolandElectricity and Radiation Department, Central Office of Measures, 00-139 Warszawa, PolandElectricity and Radiation Department, Central Office of Measures, 00-139 Warszawa, PolandElectricity and Radiation Department, Central Office of Measures, 00-139 Warszawa, PolandThis paper addresses issues relating to the temperature stability of impedance infrastructure used for the realization of impedance units and the calibration of measuring instruments. A description of the new infrastructure for impedance metrology recently developed in Poland is provided. We present the results of measurements of temperature coefficients for four-port resistance standards and two-port capacitors used in the permuting capacitor device. We also report the results of stability tests of the recently developed temperature-controlled capacitance set. The results demonstrate excellent temperature stability for the impedance components and serve as an important source of information for selecting environmental conditions during comparisons and routine calibration.https://www.mdpi.com/1996-1073/18/12/3018temperature chambertemperature stabilityimpedance standardspermuting capacitor device |
| spellingShingle | Marian Kampik Krzysztof Musioł Ryszard Rybski Janusz Kaczmarek Mirosław Kozioł Maciej Koszarny Adam Ziółek Jolanta Jursza Paweł Zawadzki Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology Energies temperature chamber temperature stability impedance standards permuting capacitor device |
| title | Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology |
| title_full | Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology |
| title_fullStr | Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology |
| title_full_unstemmed | Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology |
| title_short | Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology |
| title_sort | temperature dependence of the new calibration infrastructure for impedance metrology |
| topic | temperature chamber temperature stability impedance standards permuting capacitor device |
| url | https://www.mdpi.com/1996-1073/18/12/3018 |
| work_keys_str_mv | AT mariankampik temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology AT krzysztofmusioł temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology AT ryszardrybski temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology AT januszkaczmarek temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology AT mirosławkozioł temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology AT maciejkoszarny temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology AT adamziołek temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology AT jolantajursza temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology AT pawełzawadzki temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology |