Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology

This paper addresses issues relating to the temperature stability of impedance infrastructure used for the realization of impedance units and the calibration of measuring instruments. A description of the new infrastructure for impedance metrology recently developed in Poland is provided. We present...

Full description

Saved in:
Bibliographic Details
Main Authors: Marian Kampik, Krzysztof Musioł, Ryszard Rybski, Janusz Kaczmarek, Mirosław Kozioł, Maciej Koszarny, Adam Ziółek, Jolanta Jursza, Paweł Zawadzki
Format: Article
Language:English
Published: MDPI AG 2025-06-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/18/12/3018
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849433747130155008
author Marian Kampik
Krzysztof Musioł
Ryszard Rybski
Janusz Kaczmarek
Mirosław Kozioł
Maciej Koszarny
Adam Ziółek
Jolanta Jursza
Paweł Zawadzki
author_facet Marian Kampik
Krzysztof Musioł
Ryszard Rybski
Janusz Kaczmarek
Mirosław Kozioł
Maciej Koszarny
Adam Ziółek
Jolanta Jursza
Paweł Zawadzki
author_sort Marian Kampik
collection DOAJ
description This paper addresses issues relating to the temperature stability of impedance infrastructure used for the realization of impedance units and the calibration of measuring instruments. A description of the new infrastructure for impedance metrology recently developed in Poland is provided. We present the results of measurements of temperature coefficients for four-port resistance standards and two-port capacitors used in the permuting capacitor device. We also report the results of stability tests of the recently developed temperature-controlled capacitance set. The results demonstrate excellent temperature stability for the impedance components and serve as an important source of information for selecting environmental conditions during comparisons and routine calibration.
format Article
id doaj-art-12918f5404b64a4db043c6736cd5a55d
institution Kabale University
issn 1996-1073
language English
publishDate 2025-06-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj-art-12918f5404b64a4db043c6736cd5a55d2025-08-20T03:26:56ZengMDPI AGEnergies1996-10732025-06-011812301810.3390/en18123018Temperature Dependence of the New Calibration Infrastructure for Impedance MetrologyMarian Kampik0Krzysztof Musioł1Ryszard Rybski2Janusz Kaczmarek3Mirosław Kozioł4Maciej Koszarny5Adam Ziółek6Jolanta Jursza7Paweł Zawadzki8Department of Measurement Science, Electronics and Control, Silesian University of Technology, 44-100 Gliwice, PolandDepartment of Measurement Science, Electronics and Control, Silesian University of Technology, 44-100 Gliwice, PolandInstitute of Measurements, Electronics and Computer Science, University of Zielona Góra, 65-417 Zielona Góra, PolandInstitute of Measurements, Electronics and Computer Science, University of Zielona Góra, 65-417 Zielona Góra, PolandInstitute of Measurements, Electronics and Computer Science, University of Zielona Góra, 65-417 Zielona Góra, PolandElectricity and Radiation Department, Central Office of Measures, 00-139 Warszawa, PolandElectricity and Radiation Department, Central Office of Measures, 00-139 Warszawa, PolandElectricity and Radiation Department, Central Office of Measures, 00-139 Warszawa, PolandElectricity and Radiation Department, Central Office of Measures, 00-139 Warszawa, PolandThis paper addresses issues relating to the temperature stability of impedance infrastructure used for the realization of impedance units and the calibration of measuring instruments. A description of the new infrastructure for impedance metrology recently developed in Poland is provided. We present the results of measurements of temperature coefficients for four-port resistance standards and two-port capacitors used in the permuting capacitor device. We also report the results of stability tests of the recently developed temperature-controlled capacitance set. The results demonstrate excellent temperature stability for the impedance components and serve as an important source of information for selecting environmental conditions during comparisons and routine calibration.https://www.mdpi.com/1996-1073/18/12/3018temperature chambertemperature stabilityimpedance standardspermuting capacitor device
spellingShingle Marian Kampik
Krzysztof Musioł
Ryszard Rybski
Janusz Kaczmarek
Mirosław Kozioł
Maciej Koszarny
Adam Ziółek
Jolanta Jursza
Paweł Zawadzki
Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology
Energies
temperature chamber
temperature stability
impedance standards
permuting capacitor device
title Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology
title_full Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology
title_fullStr Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology
title_full_unstemmed Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology
title_short Temperature Dependence of the New Calibration Infrastructure for Impedance Metrology
title_sort temperature dependence of the new calibration infrastructure for impedance metrology
topic temperature chamber
temperature stability
impedance standards
permuting capacitor device
url https://www.mdpi.com/1996-1073/18/12/3018
work_keys_str_mv AT mariankampik temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology
AT krzysztofmusioł temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology
AT ryszardrybski temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology
AT januszkaczmarek temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology
AT mirosławkozioł temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology
AT maciejkoszarny temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology
AT adamziołek temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology
AT jolantajursza temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology
AT pawełzawadzki temperaturedependenceofthenewcalibrationinfrastructureforimpedancemetrology