Critical analysis and suggestions to improve the existing system of radiation control in X-ray rooms

This paper demonstrates the shortcomings of the existing method of radiation control in the X-ray rooms and the interpretation of the results of the measurements to assess the compliance of the working conditions of various groups of exposed individuals with radiation safety requirements. A new meth...

Full description

Saved in:
Bibliographic Details
Main Authors: V. Yu. Golikov, A. V. Vodovatov
Format: Article
Language:English
Published: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev 2021-06-01
Series:Радиационная гигиена
Subjects:
Online Access:https://www.radhyg.ru/jour/article/view/797
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849774188591579136
author V. Yu. Golikov
A. V. Vodovatov
author_facet V. Yu. Golikov
A. V. Vodovatov
author_sort V. Yu. Golikov
collection DOAJ
description This paper demonstrates the shortcomings of the existing method of radiation control in the X-ray rooms and the interpretation of the results of the measurements to assess the compliance of the working conditions of various groups of exposed individuals with radiation safety requirements. A new method of interpretation of the measurement results is proposed, considering the relative time spent by certain categories of exposed persons in the corresponding rooms during the use of the X-ray units, as well as the use of personal protective equipment (lead aprons). The interpretation of the measurement results in the treatment room according to the new approach has demonstrated the compliance of the working conditions to the Norms and Rules of radiation safety, provided that the worker is wearing a protective apron. The proposed approach to the interpretation of the results of the measurements in adjacent rooms leads to both reduced and stricter requirements for the stationary shielding. The paper includes a special focus on the incorrect calculation of stationary shielding for the installation of several X-ray units in one X-ray room within the framework of the current approach.
format Article
id doaj-art-120a10afdaea486b9dbac26a77048fcc
institution DOAJ
issn 1998-426X
language English
publishDate 2021-06-01
publisher Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
record_format Article
series Радиационная гигиена
spelling doaj-art-120a10afdaea486b9dbac26a77048fcc2025-08-20T03:01:49ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2021-06-01142394710.21514/1998-426X-2021-14-2-39-47699Critical analysis and suggestions to improve the existing system of radiation control in X-ray roomsV. Yu. Golikov0A. V. Vodovatov1Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-BeingSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-Being; Saint-Petersburg State Pediatric Medical UniversityThis paper demonstrates the shortcomings of the existing method of radiation control in the X-ray rooms and the interpretation of the results of the measurements to assess the compliance of the working conditions of various groups of exposed individuals with radiation safety requirements. A new method of interpretation of the measurement results is proposed, considering the relative time spent by certain categories of exposed persons in the corresponding rooms during the use of the X-ray units, as well as the use of personal protective equipment (lead aprons). The interpretation of the measurement results in the treatment room according to the new approach has demonstrated the compliance of the working conditions to the Norms and Rules of radiation safety, provided that the worker is wearing a protective apron. The proposed approach to the interpretation of the results of the measurements in adjacent rooms leads to both reduced and stricter requirements for the stationary shielding. The paper includes a special focus on the incorrect calculation of stationary shielding for the installation of several X-ray units in one X-ray room within the framework of the current approach.https://www.radhyg.ru/jour/article/view/797radiation protectionradiation controlx-ray roommedical staffambient dose equivalent
spellingShingle V. Yu. Golikov
A. V. Vodovatov
Critical analysis and suggestions to improve the existing system of radiation control in X-ray rooms
Радиационная гигиена
radiation protection
radiation control
x-ray room
medical staff
ambient dose equivalent
title Critical analysis and suggestions to improve the existing system of radiation control in X-ray rooms
title_full Critical analysis and suggestions to improve the existing system of radiation control in X-ray rooms
title_fullStr Critical analysis and suggestions to improve the existing system of radiation control in X-ray rooms
title_full_unstemmed Critical analysis and suggestions to improve the existing system of radiation control in X-ray rooms
title_short Critical analysis and suggestions to improve the existing system of radiation control in X-ray rooms
title_sort critical analysis and suggestions to improve the existing system of radiation control in x ray rooms
topic radiation protection
radiation control
x-ray room
medical staff
ambient dose equivalent
url https://www.radhyg.ru/jour/article/view/797
work_keys_str_mv AT vyugolikov criticalanalysisandsuggestionstoimprovetheexistingsystemofradiationcontrolinxrayrooms
AT avvodovatov criticalanalysisandsuggestionstoimprovetheexistingsystemofradiationcontrolinxrayrooms