Performance Assessment of Low- and Medium-Cost PM<sub>2.5</sub> Sensors in Real-World Conditions in Central Europe

In addition to the use of reference instruments, low-cost sensors (LCSs) are becoming increasingly popular for air quality monitoring both indoors and outdoors. These sensors provide real-time measurements of pollutants and facilitate better spatial and temporal coverage. However, these simpler devi...

Full description

Saved in:
Bibliographic Details
Main Authors: Bushra Atfeh, Zoltán Barcza, Veronika Groma, Ágoston Vilmos Tordai, Róbert Mészáros
Format: Article
Language:English
Published: MDPI AG 2025-06-01
Series:Atmosphere
Subjects:
Online Access:https://www.mdpi.com/2073-4433/16/7/796
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849714791645446144
author Bushra Atfeh
Zoltán Barcza
Veronika Groma
Ágoston Vilmos Tordai
Róbert Mészáros
author_facet Bushra Atfeh
Zoltán Barcza
Veronika Groma
Ágoston Vilmos Tordai
Róbert Mészáros
author_sort Bushra Atfeh
collection DOAJ
description In addition to the use of reference instruments, low-cost sensors (LCSs) are becoming increasingly popular for air quality monitoring both indoors and outdoors. These sensors provide real-time measurements of pollutants and facilitate better spatial and temporal coverage. However, these simpler devices are typically characterised by lower accuracy and precision and can be more sensitive to the environmental conditions than the reference instruments. It is therefore crucial to characterise the applicability and limitations of these instruments, for which a possible solution is their comparison with reference measurements in real-world conditions. To this end, a measurement campaign has been carried out to evaluate the PM<sub>2.5</sub> readings of several low- and medium-cost air quality instruments of different types and categories (IQAir AirVisual Pro, TSI DustTrak™ II Aerosol Monitor 8532, Xiaomi Mijia Air Detector, and Xiaomi Smartmi PM<sub>2.5</sub> Air Detector). A GRIMM EDM180 instrument was used as the reference. This campaign took place in Budapest, Hungary, from 12 November to 15 December 2020, during typically humid and foggy weather conditions, when the air pollution level was high due to the increased anthropogenic emissions, including wood burning for heating purposes. The results indicate that the individual sensors tracked the dynamics of PM<sub>2.5</sub> concentration changes well (in a linear fashion), but the readings deviated from the reference measurements to varying degrees. Even though the AirVisual sensors performed generally well (0.85 < R<sup>2</sup> < 0.93), the accuracy of the units showed inconsistency (13–93%) with typical overestimation, and their readings were significantly affected by elevated relative humidity levels and by temperature. Despite the overall overestimation of PM<sub>2.5</sub> by the Xiaomi sensors, they also exhibited strong correlation coefficients with the reference, with R<sup>2</sup> values of 0.88 and 0.94. TSI sensors exhibited slight underestimations with high explained variance (R<sup>2</sup> = 0.93–0.94) and good accuracy. The results indicated that despite the inherent bias, the low-cost sensors are capable of capturing the temporal variability of PM<sub>2.5</sub>, thus providing relevant information. After simple and multiple linear regression-based correction, the low-cost sensors provided acceptable results. The results indicate that sensor data correction is a necessary prerequisite for the usability of the instruments. The ensemble method is a reasonable alternative for more accurate estimations of PM<sub>2.5</sub>.
format Article
id doaj-art-11a3eb8a4477466daa8d188b9dff0a01
institution DOAJ
issn 2073-4433
language English
publishDate 2025-06-01
publisher MDPI AG
record_format Article
series Atmosphere
spelling doaj-art-11a3eb8a4477466daa8d188b9dff0a012025-08-20T03:13:36ZengMDPI AGAtmosphere2073-44332025-06-0116779610.3390/atmos16070796Performance Assessment of Low- and Medium-Cost PM<sub>2.5</sub> Sensors in Real-World Conditions in Central EuropeBushra Atfeh0Zoltán Barcza1Veronika Groma2Ágoston Vilmos Tordai3Róbert Mészáros4Department of Meteorology, Institute of Geography and Earth Sciences, ELTE Eötvös Loránd University, Pázmány Péter sétány 1/A, H-1117 Budapest, HungaryDepartment of Meteorology, Institute of Geography and Earth Sciences, ELTE Eötvös Loránd University, Pázmány Péter sétány 1/A, H-1117 Budapest, HungaryHUN-REN Centre for Energy Research, Konkoly-Thege út 29–33, H-1121 Budapest, HungaryDepartment of Meteorology, Institute of Geography and Earth Sciences, ELTE Eötvös Loránd University, Pázmány Péter sétány 1/A, H-1117 Budapest, HungaryDepartment of Meteorology, Institute of Geography and Earth Sciences, ELTE Eötvös Loránd University, Pázmány Péter sétány 1/A, H-1117 Budapest, HungaryIn addition to the use of reference instruments, low-cost sensors (LCSs) are becoming increasingly popular for air quality monitoring both indoors and outdoors. These sensors provide real-time measurements of pollutants and facilitate better spatial and temporal coverage. However, these simpler devices are typically characterised by lower accuracy and precision and can be more sensitive to the environmental conditions than the reference instruments. It is therefore crucial to characterise the applicability and limitations of these instruments, for which a possible solution is their comparison with reference measurements in real-world conditions. To this end, a measurement campaign has been carried out to evaluate the PM<sub>2.5</sub> readings of several low- and medium-cost air quality instruments of different types and categories (IQAir AirVisual Pro, TSI DustTrak™ II Aerosol Monitor 8532, Xiaomi Mijia Air Detector, and Xiaomi Smartmi PM<sub>2.5</sub> Air Detector). A GRIMM EDM180 instrument was used as the reference. This campaign took place in Budapest, Hungary, from 12 November to 15 December 2020, during typically humid and foggy weather conditions, when the air pollution level was high due to the increased anthropogenic emissions, including wood burning for heating purposes. The results indicate that the individual sensors tracked the dynamics of PM<sub>2.5</sub> concentration changes well (in a linear fashion), but the readings deviated from the reference measurements to varying degrees. Even though the AirVisual sensors performed generally well (0.85 < R<sup>2</sup> < 0.93), the accuracy of the units showed inconsistency (13–93%) with typical overestimation, and their readings were significantly affected by elevated relative humidity levels and by temperature. Despite the overall overestimation of PM<sub>2.5</sub> by the Xiaomi sensors, they also exhibited strong correlation coefficients with the reference, with R<sup>2</sup> values of 0.88 and 0.94. TSI sensors exhibited slight underestimations with high explained variance (R<sup>2</sup> = 0.93–0.94) and good accuracy. The results indicated that despite the inherent bias, the low-cost sensors are capable of capturing the temporal variability of PM<sub>2.5</sub>, thus providing relevant information. After simple and multiple linear regression-based correction, the low-cost sensors provided acceptable results. The results indicate that sensor data correction is a necessary prerequisite for the usability of the instruments. The ensemble method is a reasonable alternative for more accurate estimations of PM<sub>2.5</sub>.https://www.mdpi.com/2073-4433/16/7/796PM<sub>2.5</sub>low-cost sensorsair qualitysensor correction
spellingShingle Bushra Atfeh
Zoltán Barcza
Veronika Groma
Ágoston Vilmos Tordai
Róbert Mészáros
Performance Assessment of Low- and Medium-Cost PM<sub>2.5</sub> Sensors in Real-World Conditions in Central Europe
Atmosphere
PM<sub>2.5</sub>
low-cost sensors
air quality
sensor correction
title Performance Assessment of Low- and Medium-Cost PM<sub>2.5</sub> Sensors in Real-World Conditions in Central Europe
title_full Performance Assessment of Low- and Medium-Cost PM<sub>2.5</sub> Sensors in Real-World Conditions in Central Europe
title_fullStr Performance Assessment of Low- and Medium-Cost PM<sub>2.5</sub> Sensors in Real-World Conditions in Central Europe
title_full_unstemmed Performance Assessment of Low- and Medium-Cost PM<sub>2.5</sub> Sensors in Real-World Conditions in Central Europe
title_short Performance Assessment of Low- and Medium-Cost PM<sub>2.5</sub> Sensors in Real-World Conditions in Central Europe
title_sort performance assessment of low and medium cost pm sub 2 5 sub sensors in real world conditions in central europe
topic PM<sub>2.5</sub>
low-cost sensors
air quality
sensor correction
url https://www.mdpi.com/2073-4433/16/7/796
work_keys_str_mv AT bushraatfeh performanceassessmentoflowandmediumcostpmsub25subsensorsinrealworldconditionsincentraleurope
AT zoltanbarcza performanceassessmentoflowandmediumcostpmsub25subsensorsinrealworldconditionsincentraleurope
AT veronikagroma performanceassessmentoflowandmediumcostpmsub25subsensorsinrealworldconditionsincentraleurope
AT agostonvilmostordai performanceassessmentoflowandmediumcostpmsub25subsensorsinrealworldconditionsincentraleurope
AT robertmeszaros performanceassessmentoflowandmediumcostpmsub25subsensorsinrealworldconditionsincentraleurope