Determination of the Fault Zone by the Level of Short-Circuit Currents

The methods of determination the fault zone according to the parameters of the emergency mode, which can be used to improve the performance of technical perfection of current protection lines of distributive 6–10 kV one-way power networks, are considered. The advantage of the algorithm of determinat...

Full description

Saved in:
Bibliographic Details
Main Authors: F. A. Romaniuk, E. V. Buloichyk, M. A. Shevaldin
Format: Article
Language:Russian
Published: Belarusian National Technical University 2018-10-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/1395
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832557214176378880
author F. A. Romaniuk
E. V. Buloichyk
M. A. Shevaldin
author_facet F. A. Romaniuk
E. V. Buloichyk
M. A. Shevaldin
author_sort F. A. Romaniuk
collection DOAJ
description The methods of determination the fault zone according to the parameters of the emergency mode, which can be used to improve the performance of technical perfection of current protection lines of distributive 6–10 kV one-way power networks, are considered. The advantage of the algorithm of determination the zones of short circuit (SC) according to the level of emergency currents as compared to the remote unilateral method addressing the parameters of the damaged loop corrupted loops (loops) is noted. Calculation of the estimated distance to the point of SC on the basis of difference of damaged phase currents has been proposed, that enables the independence of the obtained result on the type of the fault. A technique for increasing the reliability of the method for determination the short-circuit zone by the level of emergency currents based on information about the type of damage has also been proposed. The effect of load currents and contact resistances of different levels on the magnitude and nature of the changes in the errors of the calculated distance to the short circuit was investigated by the method of computational experiment. The levels of contact resistances relative to the total resistance of the line depending on the place of SC occurrence are determined that provides reliable determination of the fault zone; it is demonstrated that the nature of their alteration is approximately the same for lines of medium and long length. The expediency of correction of the calculated distance to the fault location in many cases of short circuits through the contact resistance so to improve the protection capacity of the high-speed current protection stage is demonstrated. Based on the results of the computational experiment, correction factors for the correction of the value of the emergency current have been obtained; on the basis of the latter the fault zone is determined. The estimation of efficiency of the proposed method of correction has been carried out; it is shown that its application makes it possible to improve the accuracy of determination the fault zone and to expand the zone of instantaneous shutdown of short circuit. The dynamic properties of the proposed algorithm for different modes of the line operation have been investigated; it is ascertained that, in the worst case, the determination of the short circuit zone for a time not exceeding 27 ms is provided.
format Article
id doaj-art-119cd43201464d4b82098733e8cc616f
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2018-10-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-119cd43201464d4b82098733e8cc616f2025-02-03T05:35:38ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412018-10-0161539640710.21122/1029-7448-2018-61-5-396-4071341Determination of the Fault Zone by the Level of Short-Circuit CurrentsF. A. Romaniuk0E. V. Buloichyk1M. A. Shevaldin2Belarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityThe methods of determination the fault zone according to the parameters of the emergency mode, which can be used to improve the performance of technical perfection of current protection lines of distributive 6–10 kV one-way power networks, are considered. The advantage of the algorithm of determination the zones of short circuit (SC) according to the level of emergency currents as compared to the remote unilateral method addressing the parameters of the damaged loop corrupted loops (loops) is noted. Calculation of the estimated distance to the point of SC on the basis of difference of damaged phase currents has been proposed, that enables the independence of the obtained result on the type of the fault. A technique for increasing the reliability of the method for determination the short-circuit zone by the level of emergency currents based on information about the type of damage has also been proposed. The effect of load currents and contact resistances of different levels on the magnitude and nature of the changes in the errors of the calculated distance to the short circuit was investigated by the method of computational experiment. The levels of contact resistances relative to the total resistance of the line depending on the place of SC occurrence are determined that provides reliable determination of the fault zone; it is demonstrated that the nature of their alteration is approximately the same for lines of medium and long length. The expediency of correction of the calculated distance to the fault location in many cases of short circuits through the contact resistance so to improve the protection capacity of the high-speed current protection stage is demonstrated. Based on the results of the computational experiment, correction factors for the correction of the value of the emergency current have been obtained; on the basis of the latter the fault zone is determined. The estimation of efficiency of the proposed method of correction has been carried out; it is shown that its application makes it possible to improve the accuracy of determination the fault zone and to expand the zone of instantaneous shutdown of short circuit. The dynamic properties of the proposed algorithm for different modes of the line operation have been investigated; it is ascertained that, in the worst case, the determination of the short circuit zone for a time not exceeding 27 ms is provided.https://energy.bntu.by/jour/article/view/1395power lineovercurrent protectiontechnical excellenceshort circuit zonerelative asymmetrycontact resistancespeed performance
spellingShingle F. A. Romaniuk
E. V. Buloichyk
M. A. Shevaldin
Determination of the Fault Zone by the Level of Short-Circuit Currents
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
power line
overcurrent protection
technical excellence
short circuit zone
relative asymmetry
contact resistance
speed performance
title Determination of the Fault Zone by the Level of Short-Circuit Currents
title_full Determination of the Fault Zone by the Level of Short-Circuit Currents
title_fullStr Determination of the Fault Zone by the Level of Short-Circuit Currents
title_full_unstemmed Determination of the Fault Zone by the Level of Short-Circuit Currents
title_short Determination of the Fault Zone by the Level of Short-Circuit Currents
title_sort determination of the fault zone by the level of short circuit currents
topic power line
overcurrent protection
technical excellence
short circuit zone
relative asymmetry
contact resistance
speed performance
url https://energy.bntu.by/jour/article/view/1395
work_keys_str_mv AT faromaniuk determinationofthefaultzonebythelevelofshortcircuitcurrents
AT evbuloichyk determinationofthefaultzonebythelevelofshortcircuitcurrents
AT mashevaldin determinationofthefaultzonebythelevelofshortcircuitcurrents