Finite Element Analysis of Flat Plate Structures in Fire

Understanding the structural behaviour of flat plate systems during fire exposure is critical for ensuring the safety of occupants and emergency personnel. Flat slabs, a widely used structural system, undergo significant thermal deformations in fire, which increase demands on supporting columns and...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamed Hesien, Maged A. Youssef, Salah El-Fitiany
Format: Article
Language:English
Published: MDPI AG 2025-06-01
Series:Fire
Subjects:
Online Access:https://www.mdpi.com/2571-6255/8/7/252
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Understanding the structural behaviour of flat plate systems during fire exposure is critical for ensuring the safety of occupants and emergency personnel. Flat slabs, a widely used structural system, undergo significant thermal deformations in fire, which increase demands on supporting columns and reduce the stiffness and strength of concrete and steel. While experimental fire tests have provided valuable data to understand the behaviour of isolated components of flat slabs, numerical analysis is the only route to comprehending the structural behaviour of full-scale flat plate structures during fire exposure. ABAQUS is commonly used for modelling reinforced concrete (RC) structures under fire, with two prevailing techniques: (1) solid element modelling for concrete and truss reinforcement and (2) shell element modelling with embedded steel layers and line-column elements. However, uncertainties remain regarding the influence of modelling parameters such as dilation angle and concrete tensile stress, and the impact of surface fire exposure has not been comprehensively studied. This study presents a novel contribution by conducting a detailed numerical investigation of a full-scale flat plate structure exposed to fire using both modelling approaches. The shell-element model was validated against experimental data and used to evaluate the effect of dilation angle and tensile strength assumptions. A unique aspect of this work is the assessment of fire exposure on different slab surfaces, including bottom, top, and both, which provides insights into slab deflections and column displacements under different surface fire exposure scenarios. The structure was then modelled using solid elements to systematically compare modelling techniques. The results highlight key differences between approaches and guide for selecting the most suitable modelling strategies for fire-exposed flat plate systems.
ISSN:2571-6255