ANALYSIS OF APPLICABILITY OF EXTERNAL NETWORK SIMPLIFIED MODELS FOR DEFINITION OF SHORT CIRCUIT CURRENTS IN SYSTEMS OF RAILROAD TRACTION POWER SUPPLY

In practical methods of emergency operation in systems of tractive electric power supply systems the equivalent models of external network constructed on the basis of tractive substations short circuit (SC) reactances are used. Such modeling can give errors of definitions of SC mode parameters. The...

Full description

Saved in:
Bibliographic Details
Main Authors: V. P. Zakaryukin, A. V. Kryukov, E. A. Alekseenko
Format: Article
Language:English
Published: Kazan State Power Engineering University 2018-04-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/463
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850157772547555328
author V. P. Zakaryukin
A. V. Kryukov
E. A. Alekseenko
author_facet V. P. Zakaryukin
A. V. Kryukov
E. A. Alekseenko
author_sort V. P. Zakaryukin
collection DOAJ
description In practical methods of emergency operation in systems of tractive electric power supply systems the equivalent models of external network constructed on the basis of tractive substations short circuit (SC) reactances are used. Such modeling can give errors of definitions of SC mode parameters. The origin of errors consists of the fact that the offered estimated formulas are based on method of symmetric components with one asymmetry in three-phase circuit. Tractive network short circuit in case of double-sided supply of inter substation zone creates double asymmetry as it affects directly on two adjacent tractive substations, and in case of external network close coupling there is an interference of asymmetries at each other. For delimitation of simplified equivalent models applicability authors made comparative calculations of emergency operation by means of models constructed in phase coordinates and using external electric power supply equivalent reactances. Determination of SC currents in system of 27,5 kV tractive electric power supply of rather simple configuration is carried out in three options: on formulas of "Guide-line on relay protection of tractive electric supply ", on full-function estimated scheme of Fazonord complex considering wires capacity and inductive interferences and on specified analytical formula. The received results show rather small errors at SC power exceeding 1000 MV·A. At small values of SC power error can reach several tens percent and becomes inadmissible.
format Article
id doaj-art-10112641a4e344ce879ac4e19f96fd4a
institution OA Journals
issn 1998-9903
language English
publishDate 2018-04-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj-art-10112641a4e344ce879ac4e19f96fd4a2025-08-20T02:24:04ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032018-04-011911-12122010.30724/1998-9903-2017-19-11-12-12-20455ANALYSIS OF APPLICABILITY OF EXTERNAL NETWORK SIMPLIFIED MODELS FOR DEFINITION OF SHORT CIRCUIT CURRENTS IN SYSTEMS OF RAILROAD TRACTION POWER SUPPLYV. P. Zakaryukin0A. V. Kryukov1E. A. Alekseenko2Irkutsk State Transport University, IrkutskIrkutsk State Transport University, Irkutsk; Irkutsk National Research Technical University, IrkutskIrkutsk distance of Power Supply, structural division of Trans Power, Russian RailwayIn practical methods of emergency operation in systems of tractive electric power supply systems the equivalent models of external network constructed on the basis of tractive substations short circuit (SC) reactances are used. Such modeling can give errors of definitions of SC mode parameters. The origin of errors consists of the fact that the offered estimated formulas are based on method of symmetric components with one asymmetry in three-phase circuit. Tractive network short circuit in case of double-sided supply of inter substation zone creates double asymmetry as it affects directly on two adjacent tractive substations, and in case of external network close coupling there is an interference of asymmetries at each other. For delimitation of simplified equivalent models applicability authors made comparative calculations of emergency operation by means of models constructed in phase coordinates and using external electric power supply equivalent reactances. Determination of SC currents in system of 27,5 kV tractive electric power supply of rather simple configuration is carried out in three options: on formulas of "Guide-line on relay protection of tractive electric supply ", on full-function estimated scheme of Fazonord complex considering wires capacity and inductive interferences and on specified analytical formula. The received results show rather small errors at SC power exceeding 1000 MV·A. At small values of SC power error can reach several tens percent and becomes inadmissible.https://www.energyret.ru/jour/article/view/463railroadtractive electric power supply systemshort-circuitmodelingcurrent calculation
spellingShingle V. P. Zakaryukin
A. V. Kryukov
E. A. Alekseenko
ANALYSIS OF APPLICABILITY OF EXTERNAL NETWORK SIMPLIFIED MODELS FOR DEFINITION OF SHORT CIRCUIT CURRENTS IN SYSTEMS OF RAILROAD TRACTION POWER SUPPLY
Известия высших учебных заведений: Проблемы энергетики
railroad
tractive electric power supply system
short-circuit
modeling
current calculation
title ANALYSIS OF APPLICABILITY OF EXTERNAL NETWORK SIMPLIFIED MODELS FOR DEFINITION OF SHORT CIRCUIT CURRENTS IN SYSTEMS OF RAILROAD TRACTION POWER SUPPLY
title_full ANALYSIS OF APPLICABILITY OF EXTERNAL NETWORK SIMPLIFIED MODELS FOR DEFINITION OF SHORT CIRCUIT CURRENTS IN SYSTEMS OF RAILROAD TRACTION POWER SUPPLY
title_fullStr ANALYSIS OF APPLICABILITY OF EXTERNAL NETWORK SIMPLIFIED MODELS FOR DEFINITION OF SHORT CIRCUIT CURRENTS IN SYSTEMS OF RAILROAD TRACTION POWER SUPPLY
title_full_unstemmed ANALYSIS OF APPLICABILITY OF EXTERNAL NETWORK SIMPLIFIED MODELS FOR DEFINITION OF SHORT CIRCUIT CURRENTS IN SYSTEMS OF RAILROAD TRACTION POWER SUPPLY
title_short ANALYSIS OF APPLICABILITY OF EXTERNAL NETWORK SIMPLIFIED MODELS FOR DEFINITION OF SHORT CIRCUIT CURRENTS IN SYSTEMS OF RAILROAD TRACTION POWER SUPPLY
title_sort analysis of applicability of external network simplified models for definition of short circuit currents in systems of railroad traction power supply
topic railroad
tractive electric power supply system
short-circuit
modeling
current calculation
url https://www.energyret.ru/jour/article/view/463
work_keys_str_mv AT vpzakaryukin analysisofapplicabilityofexternalnetworksimplifiedmodelsfordefinitionofshortcircuitcurrentsinsystemsofrailroadtractionpowersupply
AT avkryukov analysisofapplicabilityofexternalnetworksimplifiedmodelsfordefinitionofshortcircuitcurrentsinsystemsofrailroadtractionpowersupply
AT eaalekseenko analysisofapplicabilityofexternalnetworksimplifiedmodelsfordefinitionofshortcircuitcurrentsinsystemsofrailroadtractionpowersupply